Skip to content
Boilers.caby ROMA Heating & Cooling

Crown Boiler Co. · Series

Crown Boiler Co. Bermuda 2 (BSIB)

The Bermuda 2 (BSIB) is Crown's current cast-iron, natural-draft gas steam boiler for residential and small commercial applications with an approved chimney — seven sizes BSI069B through BSI276B from 69 to 276 MBH input and 43 to 172 MBH AHRI net steam at 82.0–82.2% AFUE, with stainless steel burners, a built-in draft diverter, an automatic vent damper and optional near-boiler piping kits.

Current seriesunknownNatural gasPropaneresidentialcommercial

Series facts

Type
non-condensing
Efficiency
82.2% AFUE
Fuel
Standard build is natural gas; LP gas with a conversion kit per the lit sheet (NG-to-LP kits 112577-03/-05/-06/-09 and LP-to-NG kits 112578-03/-05/-06/-09 by size group).
Venting
Natural draft into an approved chimney: the lit sheet positions the line 'For residential and small commercial applications with approved chimney' and lists a built-in draft diverter to fit low spaces plus an automatic vent damper as included.
Models documented
7
Warranty
Not verified

The BSI Space Heating Ratings table prints 82.0% AFUE on BSI069B/103B/138B, 82.1% on BSI172B/207B and 82.2% on BSI241B/276B; the page and lit sheet headline 'Up to 82.2% AFUE'.

About the Bermuda 2 (BSIB)

The Bermuda 2 (BSIB) is Crown's current gas-fired steam boiler, listed under Residential Boilers – Residential Gas on velocityboilerworks.com. The product page introduces it as 'The Bermuda 2 Gas-Fired Steam Boiler', notes that it 'has many of the same features as the existing Bermuda (BSI)', and headlines seven sizes from 69 to 276 MBH, up to 82.2% AFUE, a standard natural-gas build with an LP conversion kit, and optional near-boiler piping kits. The lit sheet adds a cast-iron heat exchanger, stainless steel burners, a built-in draft diverter to fit low spaces, an automatic vent damper, a fully assembled and rugged jacket, installation on combustible floors, and the positioning 'For residential and small commercial applications with approved chimney'.

The BSI Space Heating Ratings table covers seven models — BSI069B (69 MBH input, 57 MBH DOE heating capacity, 179 sq ft / 43 MBH AHRI net steam, 82.0% AFUE), BSI103B (103/84/263/63, 82.0%), BSI138B (138/113/354/85, 82.0%), BSI172B (172/142/446/107, 82.1%), BSI207B (207/171/533/128, 82.1%), BSI241B (241/199/621/149, 82.2%) and BSI276B (276/229/717/172, 82.2%) — with net steam ratings based on a piping and pickup allowance of 1.333, over 3–9 cast-iron sections, boiler water volumes of 5.1–13.5 gallons, steamable water volumes of 1.2–3.0 gallons (normal water level to low-water cutoff) and approximate shipping weights of 350–760 lb. Dimensions are 12-3/4"–32-1/4" wide × 28" or 30" deep × 40-7/16" high.

The near-boiler piping kits (113164-01 for 069–172, 113164-02 for 207–276) are designed to help deliver 'dry' steam, reduce short cycling, eliminate water hammering and protect against system flooding per the lit sheet. Boilers.ca documents all seven models at model level from the lit sheet and the 113113-02 I&O manual; no official Canadian-sales statement was found, so canadianStatus stays 'unknown', and gas, combustion and venting work belongs with a licensed contractor.

Highlights

  • Current Crown gas steam line: Bermuda 2 (BSIB), BSI069B to BSI276B (69–276 MBH input)
  • AHRI net steam 43–172 MBH (179–717 sq ft); DOE heating capacity 57–229 MBH
  • 82.0–82.2% AFUE; standard natural gas with LP conversion kits available
  • Cast-iron heat exchanger with stainless steel burners; built-in draft diverter; automatic vent damper
  • Residential and small commercial applications with an approved chimney (lit sheet)
  • Optional near-boiler piping kits 113164-01/113164-02 to support dry steam and reduce water hammer
  • Model-level pages published on Boilers.ca; IOM 113113-02 and lit sheet 980631 linked here

Models

Bermuda 2 (BSIB) models

One canonical page per model with input, output and efficiency kept separate.

Crown Boiler Co.

Crown Bermuda 2 BSI069B

CurrentCanadian status unknown
Input
Output (max)
AFUE
82 %

The Crown Bermuda 2 BSI069B is the smallest Bermuda 2 size of the current cast-iron gas steam line: 69 MBH input, 57 MBH DOE heating capacity and a 43 MBH AHRI net steam rating (179 sq ft) at 82% AFUE, over 3 cast-iron sections with 5.1 gallons of boiler water.

Natural gasPropaneHeating-only

Crown Boiler Co.

Crown Bermuda 2 BSI103B

CurrentCanadian status unknown
Input
Output (max)
AFUE
82 %

The Crown Bermuda 2 BSI103B is a 103 MBH mid-small size of the current cast-iron gas steam line: 103 MBH input, 84 MBH DOE heating capacity and a 63 MBH AHRI net steam rating (263 sq ft) at 82% AFUE, over 4 cast-iron sections with 6.5 gallons of boiler water.

Natural gasPropaneHeating-only

Crown Boiler Co.

Crown Bermuda 2 BSI138B

CurrentCanadian status unknown
Input
Output (max)
AFUE
82 %

The Crown Bermuda 2 BSI138B is a 138 MBH mid size of the current cast-iron gas steam line: 138 MBH input, 113 MBH DOE heating capacity and a 85 MBH AHRI net steam rating (354 sq ft) at 82% AFUE, over 5 cast-iron sections with 7.9 gallons of boiler water.

Natural gasPropaneHeating-only

Crown Boiler Co.

Crown Bermuda 2 BSI172B

CurrentCanadian status unknown
Input
Output (max)
AFUE
82.1 %

The Crown Bermuda 2 BSI172B is a 172 MBH mid-large size of the current cast-iron gas steam line: 172 MBH input, 142 MBH DOE heating capacity and a 107 MBH AHRI net steam rating (446 sq ft) at 82.1% AFUE, over 6 cast-iron sections with 9.3 gallons of boiler water.

Natural gasPropaneHeating-only

Crown Boiler Co.

Crown Bermuda 2 BSI207B

CurrentCanadian status unknown
Input
Output (max)
AFUE
82.1 %

The Crown Bermuda 2 BSI207B is a 207 MBH large size of the current cast-iron gas steam line: 207 MBH input, 171 MBH DOE heating capacity and a 128 MBH AHRI net steam rating (533 sq ft) at 82.1% AFUE, over 7 cast-iron sections with 10.7 gallons of boiler water.

Natural gasPropaneHeating-only

Crown Boiler Co.

Crown Bermuda 2 BSI241B

CurrentCanadian status unknown
Input
Output (max)
AFUE
82.2 %

The Crown Bermuda 2 BSI241B is a 241 MBH large size of the current cast-iron gas steam line: 241 MBH input, 199 MBH DOE heating capacity and a 149 MBH AHRI net steam rating (621 sq ft) at 82.2% AFUE, over 8 cast-iron sections with 12.1 gallons of boiler water.

Natural gasPropaneHeating-only

Crown Boiler Co.

Crown Bermuda 2 BSI276B

CurrentCanadian status unknown
Input
Output (max)
AFUE
82.2 %

The Crown Bermuda 2 BSI276B is the largest Bermuda 2 size of the current cast-iron gas steam line: 276 MBH input, 229 MBH DOE heating capacity and a 172 MBH AHRI net steam rating (717 sq ft) at 82.2% AFUE, over 9 cast-iron sections with 13.5 gallons of boiler water.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Crown Bermuda 2 BSI069B and Crown Bermuda 2 BSI103B and Crown Bermuda 2 BSI138B and Crown Bermuda 2 BSI172B and Crown Bermuda 2 BSI207B and Crown Bermuda 2 BSI241B and Crown Bermuda 2 BSI276B
SpecificationCrown Bermuda 2 BSI069BCrown Bermuda 2 BSI103BCrown Bermuda 2 BSI138BCrown Bermuda 2 BSI172BCrown Bermuda 2 BSI207BCrown Bermuda 2 BSI241BCrown Bermuda 2 BSI276B
input-min
input-max
output-max
Efficiency (AFUE)82 %82 %82 %82.1 %82.1 %82.2 %82.2 %
turndown
vent-max-3
vent-max-2
weight

Read the full comparison: Crown Bermuda 2 BSI069B vs BSI103B

Read the full comparison: Crown Bermuda 2 BSI103B vs BSI138B

Read the full comparison: Crown Bermuda 2 BSI138B vs BSI172B

Read the full comparison: Crown Bermuda 2 BSI172B vs BSI207B

Error codes and alerts

Bermuda 2 (BSIB) alerts

No alerts documented for this series yet.

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

What sizes does the Crown Bermuda 2 come in?

Seven: BSI069B, BSI103B, BSI138B, BSI172B, BSI207B, BSI241B and BSI276B at 69, 103, 138, 172, 207, 241 and 276 MBH input, with 43–172 MBH AHRI net steam ratings and 82.0–82.2% AFUE per the BSI Space Heating Ratings table.

Can the Bermuda 2 run on propane?

Yes — the standard build is natural gas and LP gas is supported with a conversion kit (NG-to-LP kits 112577-03/-05/-06/-09 by size group per the lit sheet).

Does the Bermuda 2 need a chimney?

Yes — it is a natural-draft steam boiler for residential and small commercial applications with an approved chimney, equipped with a built-in draft diverter and an automatic vent damper. It is not a direct-vent or condensing design.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate