Dunkirk Boilers DCC/DCB (AI condensing)

The DCC (combi) and DCB (central heating) wall-hung AI condensing boilers are Dunkirk's '(While supplies last)' line: the official page prints that badge under the product title with zero current documents, all literature archived. The seven models — DCC-115/150/205 combis and DCB-75/100/125/165 heating-only — share the ECR AI platform also sold as Utica's MAC/MAH.

discontinuedunknownNatural gasPropaneresidential

Series facts

Type
combi
Efficiency
95% AFUE
Fuel
The AI control recognizes natural or LP gas automatically — no conversion kit required, as printed on the official pages.
Venting
Coaxial polypropylene 4"/2" (DCC-115/150 and DCB-75/100/125) or 5"/3" (DCC-205/DCB-165); 2-pipe polypropylene 2" or 3"; 2-pipe CPVC or PVC 3" (2-pipe requires an adapter sold separately, per the sell sheet).
Models documented
7

95% AFUE as printed for every model in the official DCC/DCB sell sheet table except the DCB-75, which prints 92% (same anomaly as Utica's MAH-75).

About the DCC/DCB (AI condensing)

The DCC/DCB family is the Dunkirk-branded version of the ECR International 'AI' wall-hung condensing platform — the same models and same manual print (PN 240013687, MGC-2209-REV-A) as Utica's MAC/MAH boilers. The official DCC page covers the combi and central-heating models together: DCC-115/150/205 combis (CH input 93.5/125/164 MBH maximum, DHW to 115.5/153/205 MBH at 2.5/3.5/5.0 GPM and a 70 °F rise) and DCB-75/100/125/165 heating-only models (75 to 164 MBH maximum CH input), with the floor-standing DCCF/DCBF versions documented on their own page at the same ratings. The AI control automatically sets up the boiler at startup, recognizes natural or LP gas without a conversion kit, and continuously monitors combustion.

Status as printed: both the DCC page and the DCB page print '(While supplies last)' under the product title and the 'Current Documents' tab is empty — all 80+ documents sit under 'Archived Documents' — so Boilers.ca records the line as discontinued (sell-through). The sell sheet prints the construction details: 316L stainless steel heat exchanger and burner with a stainless steel brazed-plate DHW heat exchanger on the combis, 95% AFUE on every model except the DCB-75 at 92% (as printed), wall-hung 30" x 17-3/4" cabinets with 13-9/16" depth on the 75–150 MBH sizes and 21-1/2" on the 165/205 sizes, weights of 94 lb (75/100), 103 lb (115/150), 104 lb (125) and 125 lb (165/205), and system supply/return at 3/4" (1" on 165/205) with the LABOR SAVER manifold included.

Owners of an installed DCC/DCB unit can still service it against the archived manual set, including the Rev. A boiler manuals hosted on the official page; the '(While supplies last)' wording means the line is in end-of-life sell-through rather than actively manufactured. The ratings are the US-market figures Dunkirk prints and no Canadian listing was verified, so canadianStatus stays 'unknown'. Gas work belongs with a licensed contractor against the unit's own documentation.

Highlights

  • Official pages print '(While supplies last)' with an empty 'Current Documents' tab — recorded discontinued (sell-through), checked 2026-09-09
  • Seven wall-hung models as printed: DCC-115/150/205 combis and DCB-75/100/125/165 heating-only (no 205-class DCB; the heat line tops at DCB-165)
  • Same ECR AI platform and shared manual print PN 240013687 as Utica's MAC/MAH
  • 95% AFUE as printed for all models except DCB-75 (92% on the sell sheet)
  • AI auto-commissioning control recognizes natural or LP gas — no conversion kit; 316L SS heat exchanger, brazed-plate DHW on combis
  • Floor versions DCCF/DCBF documented on their own page at the same ratings; not modelled separately

Free 2-year parts & labor limited warranty plus 10-year limited heat exchanger warranty, as printed on the official DCC/DCB sell sheet (unit must be registered within 60 days of the original installation; Trinity extended service terms apply).

Models

DCC/DCB (AI condensing) models

One canonical page per model with input, output and efficiency kept separate.

Dunkirk Boilers

Dunkirk DCC-115

DiscontinuedCanadian status unknown
Input
16.6–93.5 MBH
Output (max)
AFUE
95 %

The Dunkirk DCC-115 is the 115.5 MBH-class combi of the DCC 'AI' condensing line: 16.6 to 93.5 MBH central-heating input with DHW input to 115.5 MBH (2.5 GPM at a 70 °F rise), 95% AFUE and 85.4 MBH heating capacity. The DCC page prints '(While supplies last)' with no current documents, so this model is discontinued (sell-through).

Natural gasPropaneCombi

Dunkirk Boilers

Dunkirk DCC-150

DiscontinuedCanadian status unknown
Input
22–125 MBH
Output (max)
AFUE
95 %

The Dunkirk DCC-150 is the 153 MBH-class combi of the DCC 'AI' condensing line: 22 to 125 MBH central-heating input with DHW input to 153 MBH (3.5 GPM at a 70 °F rise), 95% AFUE and 113 MBH heating capacity. The DCC page prints '(While supplies last)' with no current documents, so this model is discontinued (sell-through).

Natural gasPropaneCombi

Dunkirk Boilers

Dunkirk DCC-205

DiscontinuedCanadian status unknown
Input
29.5–164 MBH
Output (max)
AFUE
95 %

The Dunkirk DCC-205 is the 205 MBH-class combi of the DCC 'AI' condensing line: 29.5 to 164 MBH central-heating input with DHW input to 205 MBH (5 GPM at a 70 °F rise), 95% AFUE and 153 MBH heating capacity. The DCC page prints '(While supplies last)' with no current documents, so this model is discontinued (sell-through).

Natural gasPropaneCombi

Dunkirk Boilers

Dunkirk DCB-75

DiscontinuedCanadian status unknown
Input
16.6–75 MBH
Output (max)
AFUE
92 %

The Dunkirk DCB-75 is the 75 MBH-class central-heating model of the DCB 'AI' condensing line: 16.6 to 75 MBH input at 92% AFUE with 68.2 MBH heating capacity and a 60 MBH net water rating. The DCB page prints '(While supplies last)' with no current documents, so this model is discontinued (sell-through).

Natural gasPropaneHeating-only

Dunkirk Boilers

Dunkirk DCB-100

DiscontinuedCanadian status unknown
Input
16.6–93.5 MBH
Output (max)
AFUE
95 %

The Dunkirk DCB-100 is the 93.5 MBH-class central-heating model of the DCB 'AI' condensing line: 16.6 to 93.5 MBH input at 95% AFUE with 85.4 MBH heating capacity and a 74 MBH net water rating. The DCB page prints '(While supplies last)' with no current documents, so this model is discontinued (sell-through).

Natural gasPropaneHeating-only

Dunkirk Boilers

Dunkirk DCB-125

DiscontinuedCanadian status unknown
Input
22–125 MBH
Output (max)
AFUE
95 %

The Dunkirk DCB-125 is the 125 MBH-class central-heating model of the DCB 'AI' condensing line: 22 to 125 MBH input at 95% AFUE with 113 MBH heating capacity and a 98 MBH net water rating. The DCB page prints '(While supplies last)' with no current documents, so this model is discontinued (sell-through).

Natural gasPropaneHeating-only

Dunkirk Boilers

Dunkirk DCB-165

DiscontinuedCanadian status unknown
Input
29.5–164 MBH
Output (max)
AFUE
95 %

The Dunkirk DCB-165 is the 164 MBH-class central-heating model of the DCB 'AI' condensing line: 29.5 to 164 MBH input at 95% AFUE with 153 MBH heating capacity and a 133 MBH net water rating. The DCB page prints '(While supplies last)' with no current documents, so this model is discontinued (sell-through).

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Dunkirk DCC-115 and Dunkirk DCC-150 and Dunkirk DCC-205 and Dunkirk DCB-75 and Dunkirk DCB-100 and Dunkirk DCB-125 and Dunkirk DCB-165
SpecificationDunkirk DCC-115Dunkirk DCC-150Dunkirk DCC-205Dunkirk DCB-75Dunkirk DCB-100Dunkirk DCB-125Dunkirk DCB-165
Central-heating input, minimum16.6 MBH22 MBH29.5 MBH16.6 MBH16.6 MBH22 MBH29.5 MBH
Central-heating input, maximum93.5 MBH125 MBH164 MBH75 MBH93.5 MBH125 MBH164 MBH
output-max
AFUE95 %95 %95 %92 %95 %95 %95 %
turndown
vent-max-3
vent-max-2
Weight103 lb103 lb125 lb94 lb94 lb104 lb125 lb

Read the full comparison: Dunkirk DCC-115 vs DCC-150

Read the full comparison: Dunkirk DCC-150 vs DCC-205

Read the full comparison: Dunkirk DCB-75 vs DCB-100

Read the full comparison: Dunkirk DCB-100 vs DCB-125

Read the full comparison: Dunkirk DCB-125 vs DCB-165

Error codes and alerts

DCC/DCB (AI condensing) alerts

  • 09DCC/DCB control
  • 10DCC/DCB control
  • 15DCC/DCB control
  • 20DCC/DCB control
  • 28DCC/DCB control
  • 40DCC/DCB control
  • 50DCC/DCB control
  • 53DCC/DCB control
  • 55DCC/DCB control
  • E72/E92DCC/DCB control
  • 78DCC/DCB control
  • 79DCC/DCB control
  • E83DCC/DCB control
  • 84-85DCC/DCB control
  • 86-87DCC/DCB control
  • 109DCC/DCB control
  • 110DCC/DCB control
  • 117DCC/DCB control
  • 118DCC/DCB control
  • 125DCC/DCB control
  • 128DCC/DCB control
  • 130DCC/DCB control
  • 131DCC/DCB control
  • 133DCC/DCB control
  • 134DCC/DCB control
  • 135DCC/DCB control
  • 160DCC/DCB control
  • 162/317DCC/DCB control
  • 169DCC/DCB control
  • 164/384DCC/DCB control
  • 165/385DCC/DCB control
  • E178DCC/DCB control
  • E62DCC/DCB control
  • E63/E65DCC/DCB control
  • E65DCC/DCB control
  • E67DCC/DCB control
  • E69DCC/DCB control
  • E70DCC/DCB control
  • E73DCC/DCB control

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

Is the Dunkirk DCC/DCB line still being sold?

The official pages print '(While supplies last)' under the product titles with zero current documents, which Boilers.ca records as discontinued (sell-through). The floor-standing DCCF/DCBF versions carry the same badge on their own page.

Is DCC/DCB the same boiler as Utica MAC/MAH?

Yes — both brands of ECR International sell the same AI wall-hung condensing platform and share the Rev. A boiler manual print PN 240013687 (MGC-2209-REV-A). DCC-115/150/205 and DCB-75/100/125/165 mirror the Utica MAC combis and MAH heating models at the same printed ratings.

Are DCC/DCB boilers condensing boilers?

Yes — they are condensing with a 316L stainless steel heat exchanger and burner (plus a brazed-plate DHW exchanger on the combis), vented coaxially in polypropylene or with 2-pipe polypropylene/CPVC/PVC.

Are DCC/DCB boilers available in Canada?

Unknown from official pages: dunkirk.com publishes US-market catalogues and no Canadian listing or distributor statement was found on the pages checked on September 9, 2026, so canadianStatus stays 'unknown'.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate