Dunkirk Boilers · XEB Series 4
Dunkirk XEB-6
The Dunkirk XEB-6 is a current induced-draft cast-iron gas water boiler: 187.5 MBH input for 158 MBH heating capacity and a 135 MBH net AHRI water rating at 84% AFUE, with 6.75 gallons of water content, a 4" chimney / 4" side wall vent option and a Honeywell recessed control at 431 lb shipping.
Key figures
- Max input
- —
- Max CSA output
- —
- AFUE
- 84 %
- Min input
- —
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Dunkirk XEB-6 in practice
The XEB-6 is one of the five sizes in Dunkirk's current XEB Series 4 line. Its ratings row prints 187.5 MBH input, 158 MBH heating capacity and a 135 MBH net water rating (1.15 allowance) at 84% AFUE, with 6.75 gallons of water content and a 4" chimney / 4" side wall vent configuration; it ships at 431 lb.
An induced-draft fan pulls flue gases through the boiler and exhausts them through a chimney or side-wall vent. The control is a Honeywell recessed operating control with digital temperature display and diagnostics; water connections are 1-1/4 in. and the gas inlet 1/2 in. NPT, on 120 V AC power at less than 12 A. The ASME-rated boiler carries a 20-year non-prorated heat-exchanger warranty for residential use.
Dunkirk keeps the older Series 3 page live alongside Series 4; Boilers.ca records the Series 4 row for the XEB-6 per the newest sell sheet and manual. No official Canadian-sales statement was found, so canadianStatus stays 'unknown', and gas, combustion and venting work belongs with a licensed contractor against the XEB Series 4 manual Rev. A.
Best suited to
- 187.5-MBH-class residential loads (158 MBH heating capacity)
- Installations that may side-wall vent or use a chimney with the induced-draft fan
- Replacement projects comparing XEB Series 3 and Series 4 documents
Applicability and support
- Model number
- XEB-6
- Canadian availability
- unknown
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Dunkirk Boilers. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input | 187.5 MBH | Input per the official ratings table (sea level to 2,000 ft; reduce 4% per 1,000 ft above 2,000 ft). |
| Output | ||
| Heating capacity | 158 MBH | Heating capacity per the official ratings table (DOE test procedures). |
| Net AHRI water rating | 135 MBH | Net AHRI water rating based on a piping and pickup allowance of 1.15 per the official ratings table. |
| Efficiency | ||
| Efficiency (AFUE) | 84 % | AFUE per the XEB Series 4 sell sheet ratings table (up to 84.4% on the XEB-2). |
| Domestic hot water | ||
| Domestic hot water | Heating-only boiler — domestic hot water comes from a separate indirect tank or water heater | |
| Venting and air | ||
| Flue | 4" chimney / 4" side wall | Induced-draft fan allowing chimney or side-wall exhaust; the sell sheet prints 4" chimney / 4" side wall for this size. |
| Physical and connections | ||
| Boiler water content | 6.75 gal | Water content per the official ratings table. |
| Dimensions | 24" wide x 29 in. high x 23-1/4 in. deep | Cabinet dimensions per the official ratings table (A width shown; height and depth as printed for the line). |
| Shipping weight | 431 lb | Shipping weight per the official ratings table. |
| Gas connection | 1/2 in. NPT gas inlet; 1-1/4 in. water return/supply. | As printed in the official ratings table connections block. |
| Electrical | ||
| Electrical | 120 V AC / 60 Hz / 1 phase, less than 12 A (15 A circuit recommended) | Per the official ratings table connections block. |
| Operating limits and other | ||
| Fuel | Natural gas or propane | Conversion kits are listed among the official options. |
Manuals
- XEB Series 4 Sell Sheet 240009715B (08/19/25) — ratings table240009715B (08/19/25)
- XEB Series 4 Boiler Manual Rev. A (240013870)240013870 Rev. A · 2025-09
Frequently asked questions
What are the XEB-6's ratings?
187.5 MBH input, 158 MBH heating capacity and a 135 MBH net AHRI water rating at 84% AFUE per the XEB Series 4 sell sheet.
Can the XEB-6 vent through a side wall?
Yes — the induced-draft fan allows chimney or side-wall exhaust; the sell sheet prints 4" chimney / 4" side wall for this size.
Is the XEB-6 a condensing boiler?
No — the XEB Series 4 is a non-condensing cast-iron boiler with an induced-draft fan, rated in the 84% AFUE class.
Questions about the Dunkirk XEB-6?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- Dunkirk — XEB Series 4 gas boiler (XEB-6 ratings) · accessed September 9, 2026
- XEB Series 4 Sell Sheet 240009715B (08/19/25) · accessed September 9, 2026
- XEB Series 4 Boiler Manual Rev. A (240013870) · accessed September 9, 2026
Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.