Skip to content
Boilers.caby ROMA Heating & Cooling

Dunkirk Boilers · Series

Dunkirk Boilers XEB Series 4

The Dunkirk XEB Series 4 is the current induced-draft cast-iron gas water boiler line: five sizes XEB-2 through XEB-6 with inputs of 42.5 to 187.5 MBH, heating capacities of 36 to 158 MBH, net AHRI water ratings of 31 to 135 MBH and up to 84.4% AFUE, vented through a chimney or side wall.

Current seriesunknownNatural gasPropaneresidential

Series facts

Type
non-condensing
Efficiency
84.4% AFUE
Fuel
Natural gas or propane conversion kits are listed among the options; the page describes the boiler as gas-fired.
Venting
Induced-draft fan allowing exhaust through a chimney or side-wall vent, per the product page; the sell sheet prints 4 in. chimney and 3 in. side-wall flue options by size.
Models documented
5

Up to 84.4% AFUE per the Series 4 sell sheet (XEB-2 at 84.4%; the remaining sizes print 84%).

About the XEB Series 4

The XEB Series 4 is documented on Dunkirk's current gas-boiler page as a cast-iron boiler whose induced-draft fan pulls flue gases through the boiler and exhausts them through a chimney or side-wall vent. The Series 4 sell sheet (240009715B, 08/19/25) prints five sizes at up to 84.4% AFUE: XEB-2 (42.5 MBH input / 36 heating capacity / 31 net water / 84.4% / 4 in. chimney–3 in. side wall / 225 lb), XEB-3 (75 / 63 / 55 / 84% / 265 lb), XEB-4 (112.5 / 95 / 82 / 84% / 322 lb), XEB-5 (150 / 127 / 109 / 84% / 370 lb) and XEB-6 (187.5 / 158 / 135 / 84% / 431 lb).

All sizes share a 29 in. height and 23-1/4 in. depth with widths from 11 to 24 in., water content from 1.75 to 6.75 gallons, 1-1/4 in. water connections and a 1/2 in. NPT gas inlet, running on 120 V AC at less than 12 A. The control is a Honeywell recessed operating control with digital temperature display and diagnostics, and the ASME-rated boiler carries a 20-year non-prorated heat-exchanger warranty for residential use.

Dunkirk keeps both the Series 3 and Series 4 pages live (the Series 3 page still carries 2023–2025 documents), so Boilers.ca records Series 4 as the current generation per the newest sell sheet and manual. No official Canadian-sales statement was found, so canadianStatus stays 'unknown', and gas, combustion and venting work belongs with a licensed contractor against the XEB Series 4 manual Rev. A.

Highlights

  • Current induced-draft cast-iron gas line: XEB-2 through XEB-6 (5 sizes, 42.5–187.5 MBH)
  • Up to 84.4% AFUE (XEB-2) with the remaining rows at 84% per the sell sheet
  • Chimney or side-wall venting via the induced-draft fan
  • Honeywell recessed control with digital display and diagnostics
  • 20-year non-prorated heat-exchanger warranty (residential)
  • Sell sheet 240009715B (08/19/25) and manual 240013870 Rev. A both live

The XEB Series 4 sell sheet prints a 20-year non-prorated heat-exchanger warranty for residential use.

Models

XEB Series 4 models

One canonical page per model with input, output and efficiency kept separate.

Dunkirk Boilers

Dunkirk XEB-2

CurrentCanadian status unknown
Input
Output (max)
AFUE
84.4 %

The Dunkirk XEB-2 is a current induced-draft cast-iron gas water boiler: 42.5 MBH input for 36 MBH heating capacity and a 31 MBH net AHRI water rating at 84.4% AFUE, with 1.75 gallons of water content, a 4" chimney / 3" side wall vent option and a Honeywell recessed control at 225 lb shipping.

Natural gasPropaneHeating-only

Dunkirk Boilers

Dunkirk XEB-3

CurrentCanadian status unknown
Input
Output (max)
AFUE
84 %

The Dunkirk XEB-3 is a current induced-draft cast-iron gas water boiler: 75 MBH input for 63 MBH heating capacity and a 55 MBH net AHRI water rating at 84% AFUE, with 3 gallons of water content, a 4" chimney / 3" side wall vent option and a Honeywell recessed control at 265 lb shipping.

Natural gasPropaneHeating-only

Dunkirk Boilers

Dunkirk XEB-4

CurrentCanadian status unknown
Input
Output (max)
AFUE
84 %

The Dunkirk XEB-4 is a current induced-draft cast-iron gas water boiler: 112.5 MBH input for 95 MBH heating capacity and a 82 MBH net AHRI water rating at 84% AFUE, with 4.25 gallons of water content, a 4" chimney / 3" side wall vent option and a Honeywell recessed control at 322 lb shipping.

Natural gasPropaneHeating-only

Dunkirk Boilers

Dunkirk XEB-5

CurrentCanadian status unknown
Input
Output (max)
AFUE
84 %

The Dunkirk XEB-5 is a current induced-draft cast-iron gas water boiler: 150 MBH input for 127 MBH heating capacity and a 109 MBH net AHRI water rating at 84% AFUE, with 5.5 gallons of water content, a 4" chimney / 3" side wall vent option and a Honeywell recessed control at 370 lb shipping.

Natural gasPropaneHeating-only

Dunkirk Boilers

Dunkirk XEB-6

CurrentCanadian status unknown
Input
Output (max)
AFUE
84 %

The Dunkirk XEB-6 is a current induced-draft cast-iron gas water boiler: 187.5 MBH input for 158 MBH heating capacity and a 135 MBH net AHRI water rating at 84% AFUE, with 6.75 gallons of water content, a 4" chimney / 4" side wall vent option and a Honeywell recessed control at 431 lb shipping.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Dunkirk XEB-2 and Dunkirk XEB-3 and Dunkirk XEB-4 and Dunkirk XEB-5 and Dunkirk XEB-6
SpecificationDunkirk XEB-2Dunkirk XEB-3Dunkirk XEB-4Dunkirk XEB-5Dunkirk XEB-6
input-min
input-max
output-max
Efficiency (AFUE)84.4 %84 %84 %84 %84 %
turndown
vent-max-3
vent-max-2
Shipping weight225 lb265 lb322 lb370 lb431 lb

Read the full comparison: Dunkirk XEB-2 vs Dunkirk XEB-3

Read the full comparison: Dunkirk XEB-3 vs Dunkirk XEB-4

Read the full comparison: Dunkirk XEB-4 vs Dunkirk XEB-5

Read the full comparison: Dunkirk XEB-5 vs Dunkirk XEB-6

Error codes and alerts

XEB Series 4 alerts

  • 2Integrated boiler control (Honeywell 4200 series, numeric error codes)
  • 4Integrated boiler control (Honeywell 4200 series, numeric error codes)
  • 6Integrated boiler control (Honeywell 4200 series, numeric error codes)
  • 18Integrated boiler control (Honeywell 4200 series, numeric error codes)
  • 23Integrated boiler control (Honeywell 4200 series, numeric error codes)
  • 24Integrated boiler control (Honeywell 4200 series, numeric error codes)
  • 29Integrated boiler control (Honeywell 4200 series, numeric error codes)
  • 32Integrated boiler control (Honeywell 4200 series, numeric error codes)
  • 57Integrated boiler control (Honeywell 4200 series, numeric error codes)
  • 58Integrated boiler control (Honeywell 4200 series, numeric error codes)
  • 59Integrated boiler control (Honeywell 4200 series, numeric error codes)
  • 60Integrated boiler control (Honeywell 4200 series, numeric error codes)
  • 61Integrated boiler control (Honeywell 4200 series, numeric error codes)
  • 62Integrated boiler control (Honeywell 4200 series, numeric error codes)
  • 63Integrated boiler control (Honeywell 4200 series, numeric error codes)
  • 64Integrated boiler control (Honeywell 4200 series, numeric error codes)
  • 65Integrated boiler control (Honeywell 4200 series, numeric error codes)

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

What sizes does the XEB Series 4 come in?

Five: XEB-2 (42.5 MBH), XEB-3 (75), XEB-4 (112.5), XEB-5 (150) and XEB-6 (187.5), with heating capacities of 36 to 158 MBH per the Series 4 sell sheet.

Can the XEB Series 4 vent through a side wall?

Yes — the induced-draft fan allows exhaust through a chimney or side-wall vent, with 4 in. chimney and 3 in. side-wall flue options printed by size in the sell sheet.

Is the XEB Series 4 still current?

Yes — the Series 4 page, sell sheet (08/19/25) and manual Rev. A (09/2025) are current; the older Series 3 page also remains live with its own documents.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate