Skip to content
Boilers.caby ROMA Heating & Cooling

Dunkirk Boilers · Series

Dunkirk Boilers Royal (CO/CH)

The Royal Series is Dunkirk's current residential combi/condensing line: the CO (Combi) models — CO-90/150/200, producing domestic hot water up to 5.1 GPM — and the CH (Central Heat) heating-only models CH-80 through CH-180, all wall-hung on a stainless steel water-tube heat exchanger at 95.2% AFUE with up to 10:1 turndown. The commercial CH sizes are documented by Dunkirk on a separate page and not modelled here.

Current seriesunknownNatural gasPropaneresidential

Series facts

Type
combi
Efficiency
95.2% AFUE
Fuel
Natural gas is the factory configuration; the official pages state the boiler is easily converted to propane (LP).
Venting
Twin-pipe direct vent, Category IV, with the included 3-in-1 adjustable vent connector (PVC, CPVC, polypropylene or stainless steel); flue 3" (2" with reducer).
Models documented
8

95.2% AFUE printed for every residential Royal model in the official brochure table (PN 240013861); the product pages rate the series high efficiency at 95.2% AFUE with up to 10:1 turndown.

About the Royal (CO/CH)

The Royal Series is the current condensing line on Dunkirk's official pages, in two residential flavours sharing one platform: the CO (Combi) models — three sizes from 80,000 to 200,000 BTU/hr input — produce domestic hot water alongside central heating in one appliance, while the CH (Central Heat) models are five heating-only sizes from 80,000 to 180,000 BTU/hr input. Boilers.ca models the residential codes as printed on the official brochure table (PN 240013861 Rev. 08/12/26): CO-90/150/200 with combi:true and CH-80/100/120/150/180 as heating-only central-heat units, all at 95.2% AFUE with up to 10:1 turndown on the next-generation enhanced stainless steel water-tube heat exchanger.

Every residential size is wall-hung in the shared cabinet (H 28.23" x W 17.4" x D 16.93" per the brochure callouts, with an additional plate on the front of the combis), vented as a twin-pipe direct-vent appliance with the included 3-in-1 adjustable vent connector (PVC, CPVC, polypropylene or stainless steel; flue 3" with a 2" reducer), with 3/4" NPT CH supply/return connections (1/2" NPT DHW on the combis), 3/4" NPT gas, cascade control to 16 boilers, 0-10 V and Modbus, and a control display settable to 18 languages. The pages rate the design at under 101 lb and price the line with a 10-year heat exchanger / 5-year parts limited warranty (residential).

The commercial Royal CH models — three sizes documented on a separate commercial page (copy prints a 299,000 to 470,000 BTU/hr range with CH-299/399/499 model references, rated up to 95.1% AFUE on the CH-299 and up to 95.6% thermal on the CH-399/499) — use the DUO Power stainless steel water-tube heat exchanger and their own commercial IOM (E93.1608.035.915.B). Boilers.ca records the Royal series canadianStatus as 'unknown': these are the US-market figures Dunkirk prints, and no official Canadian (NRCan/CSA) rating listing was verified on the pages checked on September 9, 2026. Gas work belongs with a licensed contractor against the residential IOM (E93.1907.035.915.C).

Highlights

  • Dunkirk's current residential combi/condensing line per the official pages (checked 2026-09-09; all current documents dated 2025–2026)
  • CO combis (CO-90/150/200) with DHW up to 5.1 GPM at a 70 °F rise, plus CH heating-only models CH-80/100/120/150/180
  • 95.2% AFUE printed per residential model; up to 10:1 turndown; stainless steel water-tube heat exchanger
  • Wall-hung; shared 28.23 x 17.4 x 16.93 in cabinet; Category IV twin-pipe venting with the 3-in-1 adjustable connector
  • Commercial Royal CH sizes (CH-299/399/499 page copy) noted from the official pages but not modelled
  • 10-year heat exchanger / 5-year parts limited warranty (residential); canadianStatus 'unknown' pending verified Canadian rating listings

10-year heat exchanger limited warranty and 5-year parts limited warranty (residential), as printed on the official Royal CO and CH product pages (Royal Series Warranty Rev. A, PN 240013842).

Models

Royal (CO/CH) models

One canonical page per model with input, output and efficiency kept separate.

Dunkirk Boilers

Dunkirk Royal CO-90

CurrentCanadian status unknown
Input
9–80 MBH
Output (max)
AFUE
95.2 %

The Royal CO-90 is Dunkirk's 90 MBH-class wall-hung residential combi: 9 to 80 MBH central-heating input with DHW input from 9 to 90 MBH (2.5 GPM at a 70 °F rise), 95.2% AFUE, 74 MBH heating capacity and up to 10:1 turndown.

Natural gasPropaneCombi

Dunkirk Boilers

Dunkirk Royal CO-150

CurrentCanadian status unknown
Input
15–120 MBH
Output (max)
AFUE
95.2 %

The Royal CO-150 is Dunkirk's 150 MBH-class wall-hung residential combi: 15 to 120 MBH central-heating input with DHW input from 15 to 150 MBH (3.7 GPM at a 70 °F rise), 95.2% AFUE, 110 MBH heating capacity and up to 10:1 turndown.

Natural gasPropaneCombi

Dunkirk Boilers

Dunkirk Royal CO-200

CurrentCanadian status unknown
Input
20–180 MBH
Output (max)
AFUE
95.2 %

The Royal CO-200 is Dunkirk's 200 MBH-class wall-hung residential combi: 20 to 180 MBH central-heating input with DHW input from 20 to 200 MBH (5.1 GPM at a 70 °F rise), 95.2% AFUE, 167 MBH heating capacity and up to 10:1 turndown.

Natural gasPropaneCombi

Dunkirk Boilers

Dunkirk Royal CH-80

CurrentCanadian status unknown
Input
8–80 MBH
Output (max)
AFUE
95.2 %

The Royal CH-80 is Dunkirk's 80 MBH-class wall-hung residential heating-only boiler: 8 to 80 MBH central-heating input at 95.2% AFUE with 74 MBH heating capacity, a 64 MBH net AHRI water rating and up to 10:1 turndown.

Natural gasPropaneHeating-only

Dunkirk Boilers

Dunkirk Royal CH-100

CurrentCanadian status unknown
Input
10–100 MBH
Output (max)
AFUE
95.2 %

The Royal CH-100 is Dunkirk's 100 MBH-class wall-hung residential heating-only boiler: 10 to 100 MBH central-heating input at 95.2% AFUE with 92 MBH heating capacity, a 80 MBH net AHRI water rating and up to 10:1 turndown.

Natural gasPropaneHeating-only

Dunkirk Boilers

Dunkirk Royal CH-120

CurrentCanadian status unknown
Input
12–120 MBH
Output (max)
AFUE
95.2 %

The Royal CH-120 is Dunkirk's 120 MBH-class wall-hung residential heating-only boiler: 12 to 120 MBH central-heating input at 95.2% AFUE with 110 MBH heating capacity, a 96 MBH net AHRI water rating and up to 10:1 turndown.

Natural gasPropaneHeating-only

Dunkirk Boilers

Dunkirk Royal CH-150

CurrentCanadian status unknown
Input
15–150 MBH
Output (max)
AFUE
95.2 %

The Royal CH-150 is Dunkirk's 150 MBH-class wall-hung residential heating-only boiler: 15 to 150 MBH central-heating input at 95.2% AFUE with 139 MBH heating capacity, a 121 MBH net AHRI water rating and up to 10:1 turndown.

Natural gasPropaneHeating-only

Dunkirk Boilers

Dunkirk Royal CH-180

CurrentCanadian status unknown
Input
18–180 MBH
Output (max)
AFUE
95.2 %

The Royal CH-180 is Dunkirk's 180 MBH-class wall-hung residential heating-only boiler: 18 to 180 MBH central-heating input at 95.2% AFUE with 165 MBH heating capacity, a 143 MBH net AHRI water rating and up to 10:1 turndown.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Dunkirk Royal CO-90 and Dunkirk Royal CO-150 and Dunkirk Royal CO-200 and Dunkirk Royal CH-80 and Dunkirk Royal CH-100 and Dunkirk Royal CH-120 and Dunkirk Royal CH-150 and Dunkirk Royal CH-180
SpecificationDunkirk Royal CO-90Dunkirk Royal CO-150Dunkirk Royal CO-200Dunkirk Royal CH-80Dunkirk Royal CH-100Dunkirk Royal CH-120Dunkirk Royal CH-150Dunkirk Royal CH-180
Central-heating input, minimum9 MBH15 MBH20 MBH8 MBH10 MBH12 MBH15 MBH18 MBH
Central-heating input, maximum80 MBH120 MBH180 MBH80 MBH100 MBH120 MBH150 MBH180 MBH
output-max
AFUE95.2 %95.2 %95.2 %95.2 %95.2 %95.2 %95.2 %95.2 %
TurndownUp to 10:1Up to 10:1Up to 10:1Up to 10:1Up to 10:1Up to 10:1Up to 10:1Up to 10:1
vent-max-3
vent-max-2
weight

Read the full comparison: Dunkirk Royal CO-90 vs CO-150

Read the full comparison: Dunkirk Royal CO-150 vs CO-200

Read the full comparison: Dunkirk Royal CO-90 vs CH-80

Read the full comparison: Dunkirk Royal CH-80 vs CH-100

Read the full comparison: Dunkirk Royal CH-100 vs CH-120

Read the full comparison: Dunkirk Royal CH-120 vs CH-150

Read the full comparison: Dunkirk Royal CH-150 vs CH-180

Error codes and alerts

Royal (CO/CH) alerts

  • 0Royal control (lockout/blocking/warning codes)
  • 1Royal control (lockout/blocking/warning codes)
  • 2Royal control (lockout/blocking/warning codes)
  • 3Royal control (lockout/blocking/warning codes)
  • 4Royal control (lockout/blocking/warning codes)
  • 5Royal control (lockout/blocking/warning codes)
  • 6Royal control (lockout/blocking/warning codes)
  • 7Royal control (lockout/blocking/warning codes)
  • 8Royal control (lockout/blocking/warning codes)
  • 9Royal control (lockout/blocking/warning codes)
  • 10Royal control (lockout/blocking/warning codes)
  • 11Royal control (lockout/blocking/warning codes)
  • 12Royal control (lockout/blocking/warning codes)
  • 15Royal control (lockout/blocking/warning codes)
  • 16Royal control (lockout/blocking/warning codes)
  • 17Royal control (lockout/blocking/warning codes)
  • 18Royal control (lockout/blocking/warning codes)
  • 19Royal control (lockout/blocking/warning codes)
  • 20Royal control (lockout/blocking/warning codes)
  • 21Royal control (lockout/blocking/warning codes)
  • 22Royal control (lockout/blocking/warning codes)
  • 23Royal control (lockout/blocking/warning codes)
  • 27Royal control (lockout/blocking/warning codes)
  • 28Royal control (lockout/blocking/warning codes)
  • 29Royal control (lockout/blocking/warning codes)
  • 30Royal control (lockout/blocking/warning codes)
  • 32Royal control (lockout/blocking/warning codes)
  • 33Royal control (lockout/blocking/warning codes)
  • 34Royal control (lockout/blocking/warning codes)
  • 38Royal control (lockout/blocking/warning codes)
  • 100Royal control (lockout/blocking/warning codes)
  • 101Royal control (lockout/blocking/warning codes)
  • 105Royal control (lockout/blocking/warning codes)
  • 106Royal control (lockout/blocking/warning codes)
  • 107Royal control (lockout/blocking/warning codes)
  • 108Royal control (lockout/blocking/warning codes)
  • 109Royal control (lockout/blocking/warning codes)
  • 110Royal control (lockout/blocking/warning codes)
  • 111Royal control (lockout/blocking/warning codes)
  • 112Royal control (lockout/blocking/warning codes)
  • 113Royal control (lockout/blocking/warning codes)
  • 114Royal control (lockout/blocking/warning codes)
  • 116Royal control (lockout/blocking/warning codes)
  • 118Royal control (lockout/blocking/warning codes)
  • 119Royal control (lockout/blocking/warning codes)
  • 120Royal control (lockout/blocking/warning codes)
  • 122Royal control (lockout/blocking/warning codes)
  • 123Royal control (lockout/blocking/warning codes)
  • 125Royal control (lockout/blocking/warning codes)
  • 126Royal control (lockout/blocking/warning codes)
  • 127Royal control (lockout/blocking/warning codes)
  • 129Royal control (lockout/blocking/warning codes)
  • 130Royal control (lockout/blocking/warning codes)
  • 132Royal control (lockout/blocking/warning codes)
  • 134Royal control (lockout/blocking/warning codes)
  • 136Royal control (lockout/blocking/warning codes)
  • 155Royal control (lockout/blocking/warning codes)
  • 156Royal control (lockout/blocking/warning codes)
  • 164Royal control (lockout/blocking/warning codes)
  • 168Royal control (lockout/blocking/warning codes)
  • 169Royal control (lockout/blocking/warning codes)
  • 200Royal control (lockout/blocking/warning codes)
  • 202Royal control (lockout/blocking/warning codes)
  • 203Royal control (lockout/blocking/warning codes)
  • 204Royal control (lockout/blocking/warning codes)
  • 205Royal control (lockout/blocking/warning codes)
  • 206Royal control (lockout/blocking/warning codes)
  • 207Royal control (lockout/blocking/warning codes)

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

What do CO and CH mean in the Dunkirk Royal model codes?

CO is Dunkirk's Combi line (domestic hot water plus central heating in one appliance) and CH is the Central Heat line — heating-only models that leave domestic hot water to a separate tank or water heater. The CO-90/150/200 and CH-80 through CH-180 codes are printed that way in the official brochure table.

What efficiency does the Royal series print?

95.2% AFUE for every residential model in the official brochure table, with the product pages rating the series 'High Efficiency @ 95.2% AFUE with up to 10:1 Turndown'. Dunkirk's commercial CH sizes print differently (95.1% AFUE on the CH-299 and thermal figures up to 95.6% on the CH-399/499).

Is the Royal series available in Canada?

Unknown from official pages: dunkirk.com carries US-market catalogues and no Canadian (NRCan/CSA) rating listing or distributor statement was found on the pages checked on September 9, 2026, so Boilers.ca records canadianStatus 'unknown'.

Is Dunkirk's Royal series the same boiler as Utica's Oneida?

The two ECR International brands are twins on the same family platform — the Royal residential brochure (PN 240013861) prints ratings identical to the ECR Oneida residential brochure (PN 240013863) and both share the residential IOM print E93.1907.035.915.C — but Dunkirk and Utica remain separate brand catalogues.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate