HTP Elite Ultra EMERG — Cascade Boiler Lost Communication - Emergency Mode
EMERG
Cascade boiler lost communication - Emergency Mode. When in Emergency Mode the boiler operates in CH mode with a target boiler temperature = Emergency Setpoint (2.10.3 for Master boiler, 34-40.10.3 for Follower boilers). EBUS wiring (orange connector) disconnected (check the EBUS connection and wires for damage or shorts - polarity sensitive, can only be connected to NTI room sensors, zone controls, 0-10VDC clip-in modules or another EBUS connection on a different boiler; EBUS connector CN24 pin 11-12); incorrect settings (select menu 0.4.6 to set the boiler address - slaves B-FL1 up to B-FL7, master B-MAS; if not using a cascade set to B-SIN); master boiler in cascade turned off (the master boiler must be powered at all times when in a cascade - if you wish to prevent burner operation use the power button on the boiler display); incorrect wiring (bus wiring is polarity sensitive - ensure the T connection on each cascade boiler is connected to every other T and B is connected to B). The table classifies it as Clears after the issue is corrected.
If a carbon-monoxide alarm sounds
- Leave the building immediately and get fresh air.
- Call 911. Do not go back inside until emergency services say it is safe.
- Have every fuel-burning appliance inspected before use.
Only after that, call ROMA about the boiler. Official guidance: Health Canada on carbon monoxide.
Applies to
This venting or air-supply fault code is displayed by the ELU control (group fault codes) on ELU models (ELU-85WBN through ELU-199WCN), as documented in Elite Ultra (ELU) Installation Manual (Table 32 fault codes), 420010970305 / LP-700 (1.24.23) — 150/199 sizes in 420011303900 (420010970305 (LP-700)). Codes can differ between controller generations, so always check the manual that matches your unit.
- HTP Elite Ultra (ELU)
- HTP ELU-85WBN
- HTP ELU-120WBN
- HTP ELU-120WCN
- HTP ELU-150WBN
- HTP ELU-150WCN
- HTP ELU-199WBN
- HTP ELU-199WCN
Controller: ELU control (group fault codes). Source manual: 420010970305 (LP-700) (2023-01).
Why a code is not a diagnosis
A venting or air-supply code points at the combustion-air path: a blocked terminal, a restricted flue, a failed fan, or a condensate restriction. It does not say which, and running an appliance with a blocked flue is unsafe.
Safe things to observe
- If a carbon-monoxide alarm sounds anywhere in the building, leave immediately and call 911 from outside.
- From a safe distance, check that the vent terminal and combustion-air inlet are not blocked.
- Do not run the appliance while a blockage is suspected.
Do not
- Do not put anything into the vent or air-intake openings.
- Do not remove or modify vent pipe.
How professional service helps
- A technician inspects the full vent and combustion-air path, clears blockages and checks the fan.
- Combustion and safety devices are verified with an analyser and the manufacturer's procedure after any repair.
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Parts and service
Parts commonly involved
These parts appear in the documented text for this alert. A code reports a condition, not a failed part — a technician confirms the cause by testing before anything is replaced.
Burner assembly
The burner assembly is where gas and air meet and burn inside a boiler, and its condition decides whether combustion is clean or makes carbon…
What a technician checks →Boiler sensors (thermistors)
Boiler sensors are small temperature probes, usually thermistors, that tell the control how hot the water and flue gases are so it can fire safely…
What a technician checks →Zone control panel and relays
A zone control panel is the switching brain of a multi-zone hydronic system: it reads each thermostat, opens the right zone valves or starts the…
What a technician checks →
Service for this alert
- Gas Boiler Repair
Licensed gas technicians from ROMA Heating & Cooling diagnose and repair residential and light-commercial gas boilers across…
Every boiler part explained — what it does, how it fails and what a technician checks.
Documented for HTP Elite Ultra (ELU).
Frequently asked questions
Is this code a carbon-monoxide danger?
The code relates to combustion or venting, so treat any CO alarm as an emergency and call 911 from outside. The appliance itself should be checked by a technician before it runs again.
Can I clear this code myself?
Clearing a code without fixing its cause usually just brings it back. Note the code, check the safe items on this page, then call a licensed technician. If your appliance manual describes a user reset for this exact code and it stays away, no call may be needed.
Boiler locked out? Call with the alert text ready.
The brand, model and this alert are passed along when you request service online, so the technician arrives prepared.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- Elite Ultra (ELU) Installation Manual (Table 32 fault codes), 420010970305 / LP-700 (1.24.23) — 150/199 sizes in 420011303900 · 420010970305 (LP-700) · accessed September 9, 2026
Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.