n041
A notification that the cascade system temperature sensor wired to the Leader reads as open. The cascade uses the system sensor to manage the plant water temperature.
Applies to
This notification is shown by the numeric-display touch panel control on Superflow SFT-1 tankless water heaters (SFT 199-1), as documented in IBC Installation & Operating Instructions — SFT 199-1 tankless water heater, doc 84160406, sections 5.3.1–5.3.3.
Controller: numeric-display touch panel control. Source manual: 84160406 (2024-09).
Why a code is not a diagnosis
The sensor, its field wiring or its termination at the chosen input may be faulty.
Safe things to observe
- Note the notification and report it when you book service.
Do not
- Do not touch the field sensor wiring yourself.
How professional service helps
- A technician checks the system sensor termination and measures its resistance, repairing the field wiring or replacing the sensor as needed.
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Parts and service
Parts commonly involved
These parts appear in the documented text for this alert. A code reports a condition, not a failed part — a technician confirms the cause by testing before anything is replaced.
Boiler sensors (thermistors)
Boiler sensors are small temperature probes, usually thermistors, that tell the control how hot the water and flue gases are so it can fire safely…
What a technician checks →
Service for this alert
- Gas Boiler Repair
Licensed gas technicians from ROMA Heating & Cooling diagnose and repair residential and light-commercial gas boilers across…
Every boiler part explained — what it does, how it fails and what a technician checks.
Documented for IBC Technologies Superflow SFT-1 Tankless.
Boiler locked out? Call with the alert text ready.
The brand, model and this alert are passed along when you request service online, so the technician arrives prepared.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- IBC Installation & Operating Instructions — SFT 199-1 tankless water heater, doc 84160406, sections 5.3.1–5.3.3 · 84160406 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.