The Ideal Exalt Wall 155 is the mid-range heat-only model in the Exalt Wall line: 19,375 to 155,000 BTU/h input at 95% AFUE, 8:1 turndown, with a 99 lb cabinet and the same venting options as the 110.
Key figures
- Max input
- 155 MBH
- Max CSA output
- —
- AFUE
- 95 %
- Min input
- 19.375 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Ideal Exalt Wall 155 in practice
The Exalt Wall 155 fires from 19,375 to 155,000 BTU/h with the series' 8:1 turndown and 95% AFUE, giving a DOE heating capacity of 142 MBH and an AHRI net rating of 123 MBH. It is the size a heat-loss calculation reaches for on a typical detached Lower Mainland home once the building envelope, ventilation and any indirect-tank recovery load are counted.
The cabinet is unchanged from the 110 — 21.75 x 26 x 16.5 inches — while weight rises to 99 lb and water volume to 3 gallons. Connections are 3/4-inch gas, 1-inch supply/return and 3-inch vent, with 2-inch venting available up to 28 feet and 3-inch up to 100 feet. Like every Exalt Wall heat-only model it supplies space heating only, so domestic hot water is handled by a separate source.
The CTRLMax control provides plain-text diagnostics rather than numeric codes, outdoor reset, DHW priority and three configurable circulator outputs, and the unit can join an integrated cascade of up to six Exalt solo boilers. Natural-gas (IDEX155S) and propane (IDEX155LP) versions are published. No explicit Canadian sales statement was found on the official pages checked on 2026-09-09; the Exalt and Gallant submittals list ANSI Z21.13 and CSA 4.9 compliance, so Boilers.ca records canadianStatus as unknown.
Best suited to
- Detached homes whose heat-loss calculation fits within 155 MBH
- Homes pairing the boiler with an indirect tank for domestic hot water
- Installations that want 2-inch venting with a longer 3-inch fallback
Applicability and support
- Model number
- IDEX155S (NG) / IDEX155LP (LP)
- Canadian availability
- unknown
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Ideal Heating. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, minimum (NG & LP) | 19.375 MBH | 19,375 BTU/h per the official model table |
| Input, maximum (NG & LP) | 155 MBH | 155,000 BTU/h per the official model table |
| Output | ||
| DOE heating capacity | 142 MBH | Per the official model table. |
| AHRI net rating | 123 MBH | Per the official model table. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | 95% AFUE per the official model table. |
| Domestic hot water | ||
| Domestic hot water | Heating-only; pair with a separate DHW source | |
| Venting and air | ||
| Vent / air connections | 3 in | |
| Maximum vent length, 3 in | 100 ft | Per the official model table. |
| Maximum vent length, 2 in | 28 ft | Per the official model table. |
| Physical and connections | ||
| Weight | 99 lb | |
| Width | 21.75 in | |
| Height | 26 in | |
| Depth | 16.5 in | |
| Operating limits and other | ||
| Turndown ratio | 8:1 | Per the official model table. |
| Gas connection (MNPT) | 3/4 in | |
| Supply / return connections (MNPT) | 1 in | |
| Water volume | 3 gal | Per the official model table. |
| Maximum CH flow temperature | 185 °F | 185°F (85°C) per the official model table. |
Manuals
Alerts documented for this model
Frequently asked questions
How does the Exalt Wall 155 differ from the 110?
Both share the cabinet, 8:1 turndown and 95% AFUE; the 155 adds 45,000 BTU/h of input ceiling (155,000 vs 110,000 BTU/h), with a higher minimum input of 19,375 BTU/h against the 110's 13,750.
What is the DOE heating capacity of the Exalt Wall 155?
The model table lists 142 MBH DOE heating capacity and a 123 MBH AHRI net rating at a 19,375 to 155,000 BTU/h input range.
Is the Exalt Wall 155 a combi?
No — it is a heat-only boiler. The combi versions of the Exalt Wall are the 155 and 199 combi models, which add on-demand DHW through a plate heat exchanger.
Questions about the Ideal Exalt Wall 155?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- Ideal Heating NA — Exalt Wall product page and model table · accessed September 9, 2026
- Ideal Heating NA — Exalt 155 heat-only engineering submittal (2023-83) · accessed September 9, 2026
Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.