Ideal Heating · Exalt Wall (heat-only)
Ideal Exalt Wall 199
The Ideal Exalt Wall 199 is the largest heat-only model in the Exalt Wall line: 24,875 to 199,000 BTU/h input at 95% AFUE, 8:1 turndown and a 119 lb cabinet with 3-inch venting up to 100 feet.
Key figures
- Max input
- 199 MBH
- Max CSA output
- —
- AFUE
- 95 %
- Min input
- 24.875 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Ideal Exalt Wall 199 in practice
The Exalt Wall 199 tops the heat-only Exalt Wall range at 199,000 BTU/h input, with a 24,875 BTU/h minimum, a DOE heating capacity of 184 MBH and an AHRI net rating of 159 MBH. It carries the same 95% AFUE rating and 8:1 turndown as the smaller models, making it the choice for larger detached homes or small multi-suite buildings that still want a wall-hung boiler.
The cabinet stays at 21.75 x 26 x 16.5 inches; weight rises to 119 lb and water volume to 4 gallons. Unlike the 110 and 155, the model table does not list a 2-inch vent option for the 199 — venting is 3-inch up to 100 equivalent feet. Connections are 3/4-inch gas and 1-inch supply/return. As a heat-only model it needs a separate DHW source, typically an indirect tank.
The CTRLMax control and integrated six-boiler cascade function carry over from the rest of the series, and the engineering submittal documents the model for specification work. Natural-gas (IDEX199S) and propane (IDEX199LP) versions are published with natural-gas input figures. No explicit Canadian sales statement was found on the official pages checked on 2026-09-09; the Exalt and Gallant submittals list ANSI Z21.13 and CSA 4.9 compliance, so Boilers.ca records canadianStatus as unknown.
Best suited to
- Larger detached homes and small multi-suite buildings up to 199 MBH
- Projects needing the full Exalt Wall input range in the same compact cabinet
- Homes with a substantial indirect-tank recovery load
Applicability and support
- Model number
- IDEX199S (NG) / IDEX199LP (LP)
- Canadian availability
- unknown
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Ideal Heating. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, minimum (NG & LP) | 24.875 MBH | 24,875 BTU/h per the official model table |
| Input, maximum (NG & LP) | 199 MBH | 199,000 BTU/h per the official model table |
| Output | ||
| DOE heating capacity | 184 MBH | Per the official model table. |
| AHRI net rating | 159 MBH | Per the official model table. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | 95% AFUE per the official model table. |
| Domestic hot water | ||
| Domestic hot water | Heating-only; pair with a separate DHW source | |
| Venting and air | ||
| Vent / air connections | 3 in | |
| Maximum vent length, 3 in | 100 ft | Per the official model table. |
| Physical and connections | ||
| Weight | 119 lb | |
| Width | 21.75 in | |
| Height | 26 in | |
| Depth | 16.5 in | |
| Operating limits and other | ||
| Turndown ratio | 8:1 | Per the official model table. |
| Gas connection (MNPT) | 3/4 in | |
| Supply / return connections (MNPT) | 1 in | |
| Water volume | 4 gal | Per the official model table. |
| Maximum CH flow temperature | 185 °F | 185°F (85°C) per the official model table. |
Manuals
Alerts documented for this model
Frequently asked questions
What is the firing range of the Exalt Wall 199?
24,875 to 199,000 BTU/h at 95% AFUE with an 8:1 turndown, a 184 MBH DOE heating capacity and a 159 MBH AHRI net rating.
Does the Exalt Wall 199 support 2-inch venting?
No. The official model table lists only 3-inch venting for the 199, up to 100 equivalent feet; the 2-inch option appears on the 110 and 155 rows only.
Is the Exalt Wall 199 the same size as the 110?
The cabinet is the same 21.75 x 26 x 16.5 inches, but the 199 weighs 119 lb against the 110's 88 lb and holds 4 gallons against 2.
Questions about the Ideal Exalt Wall 199?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- Ideal Heating NA — Exalt Wall product page and model table · accessed September 9, 2026
- Ideal Heating NA — Exalt 199 heat-only engineering submittal (2023-84) · accessed September 9, 2026
Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.