Skip to content
Boilers.caby ROMA Heating & Cooling

Ideal Heating · Series

Ideal Heating Commodore Wall

The Commodore Wall is Ideal Heating North America's commercial wall-hung condensing boiler: the CB299W, CB399W, CB470W and CB500W models, up to 6.5:1 modulation, Modbus as standard, field-convertible fuel and cascade capacity up to 16 boilers.

Current seriesunknownNatural gasPropanecommercial

Series facts

Type
condensing
Efficiency
95.1% AFUE
Fuel
Field-convertible between natural gas and propane, per the official page.
Venting
4-inch vent/air on the CB299W and CB399W; 6-inch on the CB470W and CB500W. Published vent lengths are 200 ft except the CB399W at 121 ft.
Models documented
4

CB299W prints 95.1% AFUE; the larger models print thermal efficiency (95.5%, 95.6%, 95.1%) and combustion efficiency (95.4%, 95.1%, 94.5%).

About the Commodore Wall

The Commodore Wall is the commercial counterpart to the Exalt residential line: four wall-hung condensing models — CB299W, CB399W, CB470W and CB500W — with input ranges of 46–299, 72–399, 83–470 and 83–500 MBH. Output is published as 289, 381, 453 and 475 MBH, with AHRI net ratings of 238, 329, 394 and 413 MBH. The CB299W prints 95.1% AFUE; the larger models print thermal efficiencies of 95.5%, 95.6% and 95.1% and combustion efficiencies of 95.4%, 95.1% and 94.5%.

The series is designed for commercial plants that want a wall-hung footprint: all four models share a 17.5 x 33.33 x 21.2 inch cabinet and weigh 184 to 198 lb, with turndown ratios of 6.5:1 (299), 5.5:1 (399), 5.7:1 (470) and 6:1 (500), rated water volumes of 2.1 to 2.7 gallons, 1-1/2 inch supply/return connections and 1-inch gas connections. Venting is 4-inch on the two smaller models and 6-inch on the 470 and 500, with 200-foot vent lengths except the 399's 121 feet. Modbus is standard, BACnet is an optional accessory, and the units are field-convertible between natural gas and propane.

Cascade capacity extends to 16 boilers, and the separate Commodore Wall Cascade page publishes pre-configured rack systems of 2 to 6 boilers up to 3,000 MBH. Error history is described as easy to read on the control, and the published installation and service manual and submittal sheet document the line for specification work. As with the rest of the catalogue, no explicit Canadian sales statement was found on the official pages checked on 2026-09-09, so canadianStatus is recorded as unknown.

Highlights

  • CB299W, CB399W, CB470W and CB500W; 299 to 500 MBH input
  • CB299W prints 95.1% AFUE; larger models print up to 95.6% thermal efficiency
  • Modulation up to 6.5:1; Modbus standard, BACnet optional
  • Field-convertible between natural gas and propane
  • Cascade up to 16 boilers; rack systems available separately
  • Compact commercial cabinet: 17.5 x 33.33 x 21.2 inches, 184–198 lb

Ideal Advantage warranty program, as published on the Exalt product pages: Standard — 2-year parts and 10-year primary heat exchanger; Plus — 5-year parts, 2-year labour allowance and 10-year primary heat exchanger with registration; Elite — 6-year parts, 3-year labour and 12-year heat exchanger with registration, combustion analysis and hydronic system treatment.

Models

Commodore Wall models

One canonical page per model with input, output and efficiency kept separate.

CurrentCanadian status unknown
Input
46–299 MBH
Output (max)
—
AFUE
—

The Ideal Commodore Wall CB299W is the smallest commercial Commodore model: 46 to 299 MBH input at 95.1% AFUE, 6.5:1 modulation, Modbus standard and cascade capacity up to 16 boilers.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
72–399 MBH
Output (max)
—
AFUE
—

The Ideal Commodore Wall CB399W is a commercial wall-hung condensing boiler: 72 to 399 MBH input, 95.5% printed thermal efficiency, 5.5:1 turndown and a 329 MBH net AHRI rating with 4-inch venting.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
83–470 MBH
Output (max)
—
AFUE
—

The Ideal Commodore Wall CB470W is a commercial wall-hung condensing boiler: 83 to 470 MBH input with the line's highest printed thermal efficiency at 95.6%, a 394 MBH net AHRI rating and 6-inch venting.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
83–500 MBH
Output (max)
—
AFUE
—

The Ideal Commodore Wall CB500W is the largest Commodore Wall model: 83 to 500 MBH input, 95.1% printed thermal efficiency, a 413 MBH net AHRI rating and 6-inch venting for commercial plants.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Ideal Commodore Wall CB299W and Ideal Commodore Wall CB399W and Ideal Commodore Wall CB470W and Ideal Commodore Wall CB500W
SpecificationIdeal Commodore Wall CB299WIdeal Commodore Wall CB399WIdeal Commodore Wall CB470WIdeal Commodore Wall CB500W
Input, minimum46 MBH72 MBH83 MBH83 MBH
Input, maximum299 MBH399 MBH470 MBH500 MBH
output-max————
afue————
Turndown ratio6.5:15.5:15.7:16:1
vent-max-3————
vent-max-2————
Weight184 lb193 lb198 lb198 lb

Read the full comparison: Ideal Commodore Wall CB299W vs CB399W →

Read the full comparison: Ideal Commodore Wall CB470W vs CB500W →

Read the full comparison: Ideal Commodore Wall CB399W vs CB470W →

Read the full comparison: Ideal Commodore Wall CB299W vs CB470W →

Error codes and alerts

Commodore Wall alerts

  • 0Commodore BCU control (lockout, blocking and warning codes)
  • 1Commodore BCU control (lockout, blocking and warning codes)
  • 2Commodore BCU control (lockout, blocking and warning codes)
  • 3Commodore BCU control (lockout, blocking and warning codes)
  • 4Commodore BCU control (lockout, blocking and warning codes)
  • 5Commodore BCU control (lockout, blocking and warning codes)
  • 6Commodore BCU control (lockout, blocking and warning codes)
  • 7Commodore BCU control (lockout, blocking and warning codes)
  • 8Commodore BCU control (lockout, blocking and warning codes)
  • 9Commodore BCU control (lockout, blocking and warning codes)
  • 10Commodore BCU control (lockout, blocking and warning codes)
  • 11Commodore BCU control (lockout, blocking and warning codes)
  • 12Commodore BCU control (lockout, blocking and warning codes)
  • 13Commodore BCU control (lockout, blocking and warning codes)
  • 14Commodore BCU control (lockout, blocking and warning codes)
  • 15Commodore BCU control (lockout, blocking and warning codes)
  • 16Commodore BCU control (lockout, blocking and warning codes)
  • 17Commodore BCU control (lockout, blocking and warning codes)
  • 18Commodore BCU control (lockout, blocking and warning codes)
  • 19Commodore BCU control (lockout, blocking and warning codes)
  • 20Commodore BCU control (lockout, blocking and warning codes)
  • 21Commodore BCU control (lockout, blocking and warning codes)
  • 22Commodore BCU control (lockout, blocking and warning codes)
  • 23Commodore BCU control (lockout, blocking and warning codes)
  • 27Commodore BCU control (lockout, blocking and warning codes)
  • 28Commodore BCU control (lockout, blocking and warning codes)
  • 29Commodore BCU control (lockout, blocking and warning codes)
  • 30Commodore BCU control (lockout, blocking and warning codes)
  • 32Commodore BCU control (lockout, blocking and warning codes)
  • 33Commodore BCU control (lockout, blocking and warning codes)
  • 34Commodore BCU control (lockout, blocking and warning codes)
  • 35Commodore BCU control (lockout, blocking and warning codes)
  • 36Commodore BCU control (lockout, blocking and warning codes)
  • 100Commodore BCU control (lockout, blocking and warning codes)
  • 101Commodore BCU control (lockout, blocking and warning codes)
  • 102Commodore BCU control (lockout, blocking and warning codes)
  • 103Commodore BCU control (lockout, blocking and warning codes)
  • 104Commodore BCU control (lockout, blocking and warning codes)
  • 105Commodore BCU control (lockout, blocking and warning codes)
  • 106Commodore BCU control (lockout, blocking and warning codes)
  • 107Commodore BCU control (lockout, blocking and warning codes)
  • 108Commodore BCU control (lockout, blocking and warning codes)
  • 109Commodore BCU control (lockout, blocking and warning codes)
  • 110Commodore BCU control (lockout, blocking and warning codes)
  • 111Commodore BCU control (lockout, blocking and warning codes)
  • 112Commodore BCU control (lockout, blocking and warning codes)
  • 113Commodore BCU control (lockout, blocking and warning codes)
  • 114Commodore BCU control (lockout, blocking and warning codes)
  • 116Commodore BCU control (lockout, blocking and warning codes)
  • 118Commodore BCU control (lockout, blocking and warning codes)
  • 119Commodore BCU control (lockout, blocking and warning codes)
  • 120Commodore BCU control (lockout, blocking and warning codes)
  • 122Commodore BCU control (lockout, blocking and warning codes)
  • 123Commodore BCU control (lockout, blocking and warning codes)
  • 125Commodore BCU control (lockout, blocking and warning codes)
  • 126Commodore BCU control (lockout, blocking and warning codes)
  • 127Commodore BCU control (lockout, blocking and warning codes)
  • 129Commodore BCU control (lockout, blocking and warning codes)
  • 130Commodore BCU control (lockout, blocking and warning codes)
  • 132Commodore BCU control (lockout, blocking and warning codes)
  • 134Commodore BCU control (lockout, blocking and warning codes)
  • 136Commodore BCU control (lockout, blocking and warning codes)
  • 155Commodore BCU control (lockout, blocking and warning codes)
  • 162Commodore BCU control (lockout, blocking and warning codes)
  • 164Commodore BCU control (lockout, blocking and warning codes)
  • 167Commodore BCU control (lockout, blocking and warning codes)
  • 168Commodore BCU control (lockout, blocking and warning codes)
  • 169Commodore BCU control (lockout, blocking and warning codes)
  • 200Commodore BCU control (lockout, blocking and warning codes)
  • 202Commodore BCU control (lockout, blocking and warning codes)
  • 203Commodore BCU control (lockout, blocking and warning codes)
  • 204Commodore BCU control (lockout, blocking and warning codes)
  • 205Commodore BCU control (lockout, blocking and warning codes)
  • 206Commodore BCU control (lockout, blocking and warning codes)
  • 207Commodore BCU control (lockout, blocking and warning codes)

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

What are the Commodore Wall model numbers?

CB299W, CB399W, CB470W and CB500W, with input ranges of 46–299, 72–399, 83–470 and 83–500 MBH and outputs of 289, 381, 453 and 475 MBH per the official table.

What efficiency does the Commodore Wall print?

The CB299W is listed at 95.1% AFUE. The CB399W, CB470W and CB500W rows print thermal efficiency of 95.5%, 95.6% and 95.1% with combustion efficiency of 95.4%, 95.1% and 94.5%.

Can Commodore Wall boilers be cascaded?

Yes — up to 16 boilers per the official page. The separate Commodore Wall Cascade rack systems join 2 to 6 boilers with total inputs from 598 to 3,000 MBH.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate