Laars Heating Systems · Mascot II (discontinued)
Laars Mascot II LMH
The Laars Mascot II LMH is the discontinued heating-only version of the 125 MBTU/h Mascot II wall-mounted modulating boiler: 125 MBH input, 115 MBH output and 95.0% AFUE, with no domestic-water production built in.
Key figures
- Max input
- 125 MBH
- Max CSA output
- 115 MBH
- AFUE
- 95 %
- Min input
- —
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Laars Mascot II LMH in practice
The LMH is the wall-mounted modulating boiler of the Mascot II line, printed on the Document 1230E manual cover at 125 MBTU/h and rated in the 1234D brochure at 95.0% AFUE with 125 MBH maximum input and 115 MBH maximum output. It shares the 100 lb wall-hung cabinet, the 1/2 in NPT gas connection and the 3/4 in NPT supply and return connections with the LMC combi.
Because it is heating-only, the LMH leaves domestic hot water to a separate tank or water heater; the manual's hydronic piping sections show it controlling an indirect water heater through the internal three-way valve. The brochure lists the Mascot II's 5:1 turndown, 10 ppm NOx, built-in expansion tank for 26 gallons of system water, sealed combustion and 2-year parts / 12-year heat exchanger warranty.
Best suited to
- Homes replacing a 125 MBH wall-hung boiler where domestic water is handled separately
- Radiant-floor systems that benefit from condensing operation
- Retrofits that can use the Mascot II's 2 in two-pipe or 3/5 in concentric venting
Applicability and support
- Model number
- LMH
- Canadian availability
- historical
- Production status
- discontinued
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Not verified
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Laars Heating Systems. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input (as printed) | 125 MBH | Maximum input, 125 MBH (36.6 kW), per the Mascot II brochure's specifications table. |
| Output | ||
| Output (as printed) | 115 MBH | Maximum output, 115 MBH (35.5 kW), per the Mascot II brochure's specifications table. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | 95.0% AFUE printed in the Mascot II brochure. |
| Domestic hot water | ||
| Domestic hot water | None built in — heating-only model; hot water comes from a separate tank or water heater | |
| Venting and air | ||
| Venting | Two-pipe 2 in or concentric 3/5 in | Per the brochure's specifications table. |
| Physical and connections | ||
| Gas connection | 1/2" NPT | Per the brochure. |
| Supply / return connections | 3/4" NPT / 3/4" NPT | Per the brochure. |
| Pressure relief setting | 30 psi | Per the brochure. |
| Weight | 100 lb | Per the brochure. |
| Operating limits and other | ||
| Turndown | 5:1 (20%–100% modulation) | 20% to 100% modulating gas valve per the brochure. |
| Fuel | Natural gas or propane | Natural gas or propane; the brochure says boilers are set up for natural gas with no parts needed for LP conversion. |
Manuals
Alerts documented for this model
None documented yet.
Frequently asked questions
Does the LMH produce domestic hot water?
No. The LMH is the heating-only Mascot II; domestic hot water comes from a separate tank or water heater. The LMC is the combi version of the same 125 MBTU/h platform.
What is the LMH's efficiency?
The Mascot II brochure prints 95.0% AFUE for the line, with 125 MBH maximum input and 115 MBH maximum output.
Is the Mascot II LMH still available?
Laars files the Mascot II manuals under Discontinued Documents, so the line is discontinued; the legacy product page still hosts the 1230 manual and parts list.
Questions about the Laars Mascot II LMH?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- Laars Heating Systems — official site · accessed September 7, 2026
- Laars — contact (Laars Canada, 9 Brigden Gate, Halton Hills, Ontario) · accessed September 7, 2026
- Laars — Document Library (Discontinued Documents category) · accessed September 9, 2026
- Laars — Discontinued Documents · accessed September 9, 2026
- Laars — Mascot II product page · accessed September 9, 2026
- Laars — Mascot II Installation and Operation Instructions, Document 1230E · 1230E · accessed September 9, 2026
- Laars — Mascot II Brochure, Document 1234D · 1234D · accessed September 9, 2026
Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.