Lochinvar · FTXL (FTX)

Lochinvar FTXL FTX725

The FTXL FTX725 fires 103.6 to 725 MBH with 705 MBH gross output and a 613 MBH AHRI net rating at 97.2% submittal thermal efficiency, stepping to 2-1/2" water connections and a 6" vent.

CurrentSold in Canada

Key figures

Max input
725 MBH
Max CSA output
AFUE
Min input
103.6 MBH
Natural gasPropaneHeating-onlycommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Lochinvar FTXL FTX725 in practice

The FTX725 is the first FTXL size that steps its plant connections: the I&O ratings table lists 103.6 to 725 MBH input with 705 MBH gross output and a 613 MBH AHRI net water rating at 97.2% submittal thermal efficiency, with a 17.2-gallon water content. Water connections grow to 2-1/2" while the gas connection stays 1", and the air intake stays 4" while the vent steps to 6".

Turndown is 7:1 per the submittal (matching the 103.6 MBH minimum input). The unit vents in PVC, CPVC, polypropylene or AL29-4C stainless steel to 100 equivalent feet per the submittal, carries the SMART TOUCH control with CON·X·US and an ASME H stamp on the stainless steel fire-tube platform, and the submittal lists a 575 lb shipping weight.

Best suited to

  • Commercial heating plants with design-day loads between 600 and 725 MBH
  • Projects already planning 2-1/2" near-boiler piping
  • Systems comfortable with a 103.6 MBH minimum fire

Applicability and support

Model number
FTX725N
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Lochinvar. Units are shown with every value; notes flag conflicting sources or missing figures.

Lochinvar FTXL FTX725 specifications
SpecificationValueNote
Input
Heating input, minimum103.6 MBHPer the I&O ratings table.
Heating input, maximum725 MBHPer the I&O ratings table.
Output
Gross output705 MBHPer the I&O ratings table.
Net AHRI water rating613 MBHPer the I&O ratings table.
Efficiency
Efficiency (thermal)97.2 %97.2% thermal efficiency per the FTXL submittal.
Venting and air
Air inlet size4"Per the I&O ratings table.
Vent size6"Per the I&O ratings table.
VentingCategory IV sealed combustion; room air/direct vent in PVC, CPVC, polypropylene or AL29-4C stainless steelDirect vent to 100 equivalent feet per the FTXL submittal and the product-page feature list; common vent kit available.
Physical and connections
Water content17.2 galPer the I&O ratings table.
Space-heating water connections2-1/2"Per the I&O ratings table.
Gas connection1"Per the I&O ratings table.
Shipping weight575 lbShipping weight per the FTXL submittal.

Frequently asked questions

What are the FTX725's ratings?

103.6 to 725 MBH of input with 705 MBH gross output and a 613 MBH AHRI net water rating at 97.2% thermal efficiency per the FTXL submittal.

How does the FTX725 connect?

2-1/2" water connections, a 1" gas connection, a 4" air intake and a 6" vent per the I&O ratings table, with a 17.2-gallon water content.

Questions about the Lochinvar FTXL FTX725?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.