Lochinvar FTXL FTX600

The FTXL FTX600 reaches 85.7 to 600 MBH input with 585 MBH gross output and a 509 MBH AHRI net rating at 97.5% submittal thermal efficiency, with 7:1 turndown.

CurrentSold in Canada

Key figures

Max input
600 MBH
Max CSA output
—
AFUE
—
Min input
85.7 MBH
Natural gasPropaneHeating-onlycommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Lochinvar FTXL FTX600 in practice

The FTX600 is the first FTXL size whose turndown tightens: the ratings table's 85.7 MBH minimum against the 600 MBH maximum matches the 7:1 figure the submittal prints for the 600, 725 and 850 sizes. The I&O ratings table lists 585 MBH gross output and a 509 MBH AHRI net water rating at 97.5% submittal thermal efficiency.

It keeps the 2" water and 1" gas connections of the smaller sizes with an 11.9-gallon water content, a 4" air intake and 4" vent, and vents in PVC, CPVC, polypropylene or AL29-4C stainless steel to 100 equivalent feet per the submittal. The stainless steel fire-tube heat exchanger, SMART TOUCH control with CON·X·US and ASME H stamp carry over from the rest of the family, and the submittal lists a 504 lb shipping weight.

Best suited to

  • Commercial loads between 500 and 600 MBH on a design day
  • Plants where an 85.7 MBH minimum fire still tracks part loads
  • Systems that stay within 4" venting at 600 MBH

Applicability and support

Model number
FTX600N
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Lochinvar. Units are shown with every value; notes flag conflicting sources or missing figures.

Lochinvar FTXL FTX600 specifications
SpecificationValueNote
Input
Heating input, minimum85.7 MBHPer the I&O ratings table.
Heating input, maximum600 MBHPer the I&O ratings table.
Output
Gross output585 MBHPer the I&O ratings table.
Net AHRI water rating509 MBHPer the I&O ratings table.
Efficiency
Efficiency (thermal)97.5 %97.5% thermal efficiency per the FTXL submittal.
Venting and air
Air inlet size4"Per the I&O ratings table.
Vent size4"Per the I&O ratings table.
VentingCategory IV sealed combustion; room air/direct vent in PVC, CPVC, polypropylene or AL29-4C stainless steelDirect vent to 100 equivalent feet per the FTXL submittal and the product-page feature list; common vent kit available.
Physical and connections
Water content11.9 galPer the I&O ratings table.
Space-heating water connections2"Per the I&O ratings table.
Gas connection1"Per the I&O ratings table.
Shipping weight504 lbShipping weight per the FTXL submittal.

Frequently asked questions

What turndown does the FTX600 have?

7:1 per the FTXL submittal: the ratings table lists an 85.7 MBH minimum input against the 600 MBH maximum.

What are the FTX600's ratings?

85.7 to 600 MBH of input with 585 MBH gross output and a 509 MBH AHRI net water rating at 97.5% thermal efficiency per the submittal.

Questions about the Lochinvar FTXL FTX600?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate