Lochinvar · Knight Floor Mount (KHB)

Lochinvar Knight KHB085

The Knight KHB085 is the 85 MBH floor-standing Knight: 8.5 to 85 MBH input at 95% AFUE with 79 MBH DOE capacity, sharing the WHB085's ratings on a floor frame.

CurrentSold in Canada

Key figures

Max input
85 MBH
Max CSA output
AFUE
95 %
Min input
8.5 MBH
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Lochinvar Knight KHB085 in practice

The KHB085 matches the wall-hung WHB085 figure for figure: 8.5 to 85 MBH of input, 79 MBH of DOE heating capacity, a 69 MBH AHRI net rating and 95% AFUE in the KHB I&O ratings table. For a basement floor installation it delivers the same low 8.5 MBH minimum fire as the wall version.

The floor boiler keeps the 1" heating connections, 1/2" gas connection and 2.2-gallon water content of its wall twin, and its venting is 2" to 50 equivalent feet or 3" to 100. Heating-only by design, it takes domestic hot water from an indirect tank such as the Squire, with the SMART SYSTEM providing the tank thermostat function.

Best suited to

  • Homes needing 55-85 MBH of headroom on a floor-standing boiler
  • Basement plants where an indirect tank sits beside the boiler
  • Retrofits replacing a floor-standing boiler on an existing pad

Applicability and support

Model number
KHB085L
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Lochinvar. Units are shown with every value; notes flag conflicting sources or missing figures.

Lochinvar Knight KHB085 specifications
SpecificationValueNote
Input
Heating input, minimum8.5 MBHPer the I&O ratings table.
Heating input, maximum85 MBHPer the I&O ratings table.
Output
DOE heating capacity79 MBHDOE heating capacity per the I&O ratings table.
AHRI net water rating69 MBHNet AHRI rating based on a piping and pickup allowance of 1.15.
Efficiency
Efficiency (AFUE)95 %95% AFUE per the I&O ratings table.
Domestic hot water
Domestic hot waterHeating-only boilerPairs with the Squire indirect water heater or another indirect tank; the Knight is heating-only.
Venting and air
VentingCategory IV sealed combustion; PVC, CPVC, polypropylene or stainless steelIn Canada, plastic venting must be a ULC S636-certified system.
Max. equivalent vent/air length, 2"50 ftTable 3D (air intake/vent piping sizes), I&O manual.
Max. equivalent vent/air length, 3"100 ftTable 3D (air intake/vent piping sizes), I&O manual.
Physical and connections
Water content2.2 galPer the I&O ratings table.
Space-heating water connections1"Per the I&O ratings table.
Gas connection1/2"Per the I&O ratings table.

Frequently asked questions

Does the KHB085 need a wall for mounting?

No. The KHB is floor-standing, which is the point of the model versus the wall-hung WHB: it stands on the floor or a pad and reaches 85 MBH with the same ratings as the WHB085.

How is the KHB085 vented?

In 2" pipe to 50 equivalent feet or 3" pipe to 100, per Table 3D of the I&O manual. In Canada the plastic vent system must be ULC S636 certified.

Questions about the Lochinvar Knight KHB085?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.