Lochinvar · Knight Floor Mount (KHB)
Lochinvar Knight KHB110
The Knight KHB110 is the 110 MBH floor-standing Knight: 11 to 110 MBH input at 95% AFUE with 102 MBH DOE capacity, matching the wall-hung WHB110 on a floor frame.
Key figures
- Max input
- 110 MBH
- Max CSA output
- —
- AFUE
- 95 %
- Min input
- 11 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Lochinvar Knight KHB110 in practice
The KHB110 brings the mid-size Knight ratings to the floor: 11 to 110 MBH of input with 102 MBH of DOE heating capacity and an 89 MBH AHRI net rating at 95% AFUE, identical to the wall-hung WHB110 in the KHB I&O ratings table. Homes whose heat-loss calculation lands near 100 MBH and whose mechanical room favors a floor boiler are its market.
It holds 2.3 gallons of water, connects on 1" heating fittings with a 1/2" gas connection, and — like the WHB110 — its 2" venting is capped at 40 equivalent feet, with 3" reaching 100. As a heating-only boiler it works with an indirect tank for domestic hot water, and the SMART SYSTEM control handles the tank thermostat and sensor inputs.
Best suited to
- Detached homes with loads around 100 MBH and a floor-mount preference
- Basement rooms where the boiler shares space with the indirect tank
- Projects with 3" vent routes to 100 equivalent feet
Applicability and support
- Model number
- KHB110L
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Lochinvar. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Heating input, minimum | 11 MBH | Per the I&O ratings table. |
| Heating input, maximum | 110 MBH | Per the I&O ratings table. |
| Output | ||
| DOE heating capacity | 102 MBH | DOE heating capacity per the I&O ratings table. |
| AHRI net water rating | 89 MBH | Net AHRI rating based on a piping and pickup allowance of 1.15. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | 95% AFUE per the I&O ratings table. |
| Domestic hot water | ||
| Domestic hot water | Heating-only boiler | Pairs with the Squire indirect water heater or another indirect tank; the Knight is heating-only. |
| Venting and air | ||
| Venting | Category IV sealed combustion; PVC, CPVC, polypropylene or stainless steel | In Canada, plastic venting must be a ULC S636-certified system. |
| Max. equivalent vent/air length, 2" | 40 ft | Table 3D (air intake/vent piping sizes), I&O manual. |
| Max. equivalent vent/air length, 3" | 100 ft | Table 3D (air intake/vent piping sizes), I&O manual. |
| Physical and connections | ||
| Water content | 2.3 gal | Per the I&O ratings table. |
| Space-heating water connections | 1" | Per the I&O ratings table. |
| Gas connection | 1/2" | Per the I&O ratings table. |
Manuals
Alerts documented for this model
- Gas Pressure SW
- Flow Switch/LWCO
- Air Pressure SW
- Too Many Recyclings
- Anti-cycling
- Flame Fail Ign
- Flame Sequence
- Outlet ARHL
- Outlet MRHL
- Fan Speed
- Inlet, Outlet, or Flue Sensor Fault
- AUX Contact Sw
- Outlet Temp Diff
- Fatal Error
- Memory Error
- Flue Temp High / Flue Temp Limit
- Delta T High / Delta T Limit
- Outlet Temp High / Outlet Temp Limit
- Low 24 vac
- Watch Dog Error
- Write EEProm
- CRC Parameters
- No Error Stored
Frequently asked questions
Are the KHB110 and WHB110 the same ratings?
Yes — the floor and wall I&O ratings tables print the same figures at every shared size, including 11 to 110 MBH input, 102 MBH DOE capacity and 95% AFUE at the 110 size.
Can the KHB110 use 2" venting?
Only to 40 equivalent feet per Table 3D. Most installations use 3" pipe, which is allowed to 100 equivalent feet.
Questions about the Lochinvar Knight KHB110?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
- Lochinvar Knight KHB085 vs KHB110Comparison
- Lochinvar Knight KHB110 vs KHB155Comparison
- Lochinvar Knight KHB055Same series
- Lochinvar Knight KHB085Same series
- Lochinvar Knight KHB155Same series
- Lochinvar Knight KHB199Same series
- Lochinvar Knight KHB285Same series
- Knight Floor Mount (KHB) series hub
- Buying guide