Skip to content
Boilers.caby ROMA Heating & Cooling

Miura · Series

Miura LX Series Steam Boiler

The Miura LX Series is the company's low-NOx gas-fired industrial steam boiler — a once-through watertube design that reaches NOx as low as 5 ppm at 3% corrected O2, produces steam in under five minutes from a cold start, and is published in LX 50, 100, 150/200 and 250/300 groups from 1,730 to 10,350 lb/hr.

Current seriesunknownNatural gasPropanecommercial

Series facts

Type
non-condensing
Efficiency
87% thermal-efficiency
Fuel
The LX rating table prints 'Fuel Type: Natural Gas or Propane' for every model group.
Venting
Unknown
Models documented
4
Warranty
Not verified

The published LX table prints 85% efficiency for LX 50–200 and 87% for LX 250/300 at standard pressure; high-pressure LX 200–300 rows print 84%–86%.

About the LX Series Steam Boiler

Miura's official LX page describes the line as 'the high-efficiency, easy-to-use boiler' with 'unique design of the LX' ensuring 'safety, reliability and efficiency', reaching 'NOx regulations as low as 5 ppm NOx at 3% corrected O2'. The page states that 'while standard firetube boilers require hours to heat up, Miura's LX Series boilers produce fast steam in less than 5 minutes from a cold start-up', and that the compact design lets owners 'double your steam capacity in the same space or reduce space requirements by half for new construction'.

The published rating table prints four model groups with standard, low and high-pressure configurations: LX 50 (50 BHP, 1,730 lb/hr, 70–150 PSI, 85%), LX 100 (100 BHP, 3,450 lb/hr, 85%), LX 150/200 (150–200 BHP, 5,180–6,900 lb/hr, 85%; high pressure 200 BHP at 170–270 PSI, 84%) and LX 250/300 (250–300 BHP, 8,630–10,350 lb/hr, 87%; high pressure 170–270 PSI, 86%). Emissions are printed 'as low as 20 PPM NOx' on the LX 50, 'as low as 9 PPM NOx' on LX 100–200, 'as low as 5 PPM NOx' on the standard-pressure LX 250/300 and 'as low as 12 PPM NOx' on the high-pressure LX 250/300.

The Technical Resources page lists the exact build codes for each configuration, including LX-50SG-12, LX-100SG-12, LX-100SGN-12 (9 ppm ultra-low NOx), LX-150SG-07/SGN-07, LX-200SG-07/SGN-07, LX-250SG-C/SGN-16, LX-300SG-C/SGN-16 and LXN-300SG-A (5 ppm ultra-low NOx), plus the LXL low-pressure series (LXL-50SG-07 through LXL-200SGN-12). Miura markets the LX as part of its Multiple Installation (MI) system, where modular units stage on and off with demand and one small unit provides n+1 backup. No official Canadian-sales statement was found.

Highlights

  • Low-NOx once-through watertube steam boiler; NOx as low as 5 ppm at 3% corrected O2
  • Published model groups: LX 50, LX 100, LX 150/200, LX 250/300
  • Steam output 1,730 – 10,350 lb/hr; 50 – 300 BHP
  • Standard (70–150 PSI), low (15 PSI) and high-pressure (170–270 PSI) configurations
  • Fuel-to-steam efficiency 85% (LX 50–200) and 87% (LX 250/300 standard pressure)
  • Steam in less than 5 minutes from cold start-up; modular MI system with n+1 redundancy

Models

LX Series Steam Boiler models

One canonical page per model with input, output and efficiency kept separate.

CurrentCanadian status unknown
Input
Output (max)
AFUE

The Miura LX 50 is a low-NOx once-through watertube steam boiler rated 50 BHP with 1,730 LB/HR of steam output at 70-150 PSI standard pressure, 85% efficiency and As low as 20 PPM NOx in Miura's published rating table.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
AFUE

The Miura LX 100 is a low-NOx once-through watertube steam boiler rated 100 BHP with 3,450 LB/HR of steam output at 70-150 PSI standard pressure, 85% efficiency and As low as 9 PPM NOx in Miura's published rating table.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
AFUE

The Miura LX 150/200 is a low-NOx once-through watertube steam boiler rated 150-200 BHP with 5,180-6,900 LB/HR of steam output at 70-150 PSI standard pressure, 85% efficiency and As low as 9 PPM NOx in Miura's published rating table.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
AFUE

The Miura LX 250/300 is a low-NOx once-through watertube steam boiler rated 250-300 BHP with 8,630-10,350 LB/HR of steam output at 70-150 PSI standard pressure, 87% efficiency and As low as 5 PPM NOx (standard pressure) in Miura's published rating table.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Miura LX 50 and Miura LX 100 and Miura LX 150/200 and Miura LX 250/300
SpecificationMiura LX 50Miura LX 100Miura LX 150/200Miura LX 250/300
input-min
input-max
output-max
afue
turndown
vent-max-3
vent-max-2
weight

Read the full comparison: Miura LX 50 vs LX 100

Read the full comparison: Miura LX 100 vs LX 150/200

Read the full comparison: Miura LX 150/200 vs LX 250/300

Read the full comparison: Miura LX 250/300 vs LX 50

Error codes and alerts

LX Series Steam Boiler alerts

No alerts documented for this series yet.

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

What sizes does the Miura LX come in?

Miura's published table prints LX 50, LX 100, LX 150/200 and LX 250/300 groups, covering 50 to 300 BHP and 1,730 to 10,350 lb/hr of steam.

How low are LX NOx emissions?

The LX page prints emissions 'as low as 5 ppm NOx at 3% corrected O2' for the standard-pressure LX 250/300, with 9 ppm on LX 100–200 and 20 ppm on the LX 50; build codes with the 'SGN' suffix denote the 9 ppm versions.

Is the Miura LX a condensing boiler?

No. Miura publishes fuel-to-steam efficiencies of 85%–87% for the LX, and the line is documented as a once-through watertube steam boiler rather than a condensing appliance.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate