Navien · NFC-H Fire-Tube Combi
Navien NFC-250/175H
The Navien NFC-250/175H is the smaller NFC-H fire-tube combi: 13.3 to 175 MBH heating input, DHW input to 210,000 BTU/h, 7.9 GPM at a 45°F rise and 95.0% AFUE in a 141 lb stainless steel fire-tube cabinet.
Key figures
- Max input
- 175 MBH
- Max CSA output
- —
- AFUE
- 95 %
- Min input
- 13.3 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Navien NFC-250/175H in practice
The NFC-250/175H fires from 13,300 to 175,000 BTU/h for space heating through Navien's stainless steel fire-tube heat exchanger, the design behind this combi series, and it is rated 95.0% AFUE per the installation manual. At 141 lb and 17.3 x 17.3 x 33.5 in it is the physically largest of the Navien residential combis.
Its DHW side fires up to 210,000 BTU/h and the manual publishes 7.9 GPM of flow at a 45°F temperature rise. Water connections are 1" NPT on the heating side with 3/4" NPT DHW fittings, system pressure is rated 6 to 80 psi, and venting is 2" or 3" PVC, CPVC or approved polypropylene to 65 or 150 equivalent feet.
Best suited to
- Larger homes with radiators or in-floor heat needing up to 175 MBH of input
- Households wanting a fire-tube combi's DHW reach without the 200-class heating input
- Projects that can house the taller 33.5 in fire-tube cabinet
Applicability and support
- Model number
- NFC-250/175H
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Not verified
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Navien. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Heating input, minimum | 13.3 MBH | Space-heating input. |
| Heating input, maximum | 175 MBH | Space-heating input. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | 95.0% AFUE per the installation manual. |
| Domestic hot water | ||
| DHW input, maximum | 210 MBH | 210,000 BTU/h |
| DHW flow at 45°F rise | 7.9 GPM | Both NFC-H models, per the installation manual. |
| Domestic hot water | Integrated in the combi heat exchanger | |
| Venting and air | ||
| Venting | PVC, CPVC or approved polypropylene; 2" or 3" | Canada: plastic venting must meet ULC S636 where required. |
| Max. equivalent vent length, 2" | 65 ft | |
| Max. equivalent vent length, 3" | 150 ft | |
| Physical and connections | ||
| Weight | 141 lb | 64 kg; 170 lb (77 kg) with water. |
| Width | 17.3 in | |
| Height | 33.5 in | |
| Depth | 17.3 in | |
| Gas connection | 3/4" NPT | |
| Heating water connections | 1" NPT | |
| Operating limits and other | ||
| Fuel | Natural gas or propane | Separate Navien ratings per fuel. |
| Altitude rating | 10,100 ft | Per installation manual. |
| System water pressure | 6 – 80 psi | |
Manuals
Alerts documented for this model
Frequently asked questions
What does the NFC-250/175H's DHW rating mean?
The installation manual lists DHW input to 210,000 BTU/h and publishes DHW flow of 7.9 GPM at a 45°F temperature rise for the NFC-H models. Actual delivery depends on incoming water temperature and the draw pattern.
Is the NFC-250/175H the same boiler as an NFC-175H?
The current product pages name this model NFC-250/175H, while the NFC-H service manual (Ver 1.0, Jan 2021) covers units named NFC-175H and NFC-200H — the same generation under its earlier naming.
Can the NFC-250/175H run on propane?
Yes. Navien lists the NFC-H series for natural gas or propane; fuel conversion and setup are licensed gas-fitting work, and ratings differ by fuel.
Questions about the Navien NFC-250/175H?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- Navien Canada — NFC-H series · accessed September 7, 2026
- NFC-H Series Installation Manual (EN) · accessed September 7, 2026
- NFC-H Service Manual, Ver 1.0 (Jan 2021) · Ver 1.0 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.