Skip to content
Boilers.caby ROMA Heating & Cooling

Navien · Series

Navien NFC-H Fire-Tube Combi

The NFC-H is Navien's fire-tube condensing combi series for Canada: the NFC-250/175H and NFC-250/200H, rated 95.0% AFUE, with a stainless steel fire-tube heat exchanger and DHW flow published at 7.9 GPM on a 45°F rise.

Current seriesSold in CanadaNatural gasPropaneresidential

Series facts

Type
combi
Efficiency
95% AFUE
Fuel
Natural gas / Propane
Venting
2" or 3" PVC, CPVC or approved polypropylene; up to 65 equivalent ft in 2" and 150 in 3" per the installation manual.
Models documented
2
Warranty
Not verified

95.0% AFUE across the series per the installation manual.

About the NFC-H Fire-Tube Combi

Navien positions the NFC-H as its fire-tube combi: combustion happens inside a stainless steel fire-tube heat exchanger, which Navien's materials say resists the thermal shock and scaling that matter in a combined heating-and-hot-water appliance. Two Canadian models, the NFC-250/175H and the NFC-250/200H, fire from 13,300 BTU/h up to 175,000 or 199,900 BTU/h for space heating and are rated 95.0% AFUE.

On the domestic hot water side both NFC-H models fire up to 210,000 BTU/h, and Navien's installation manual publishes DHW flow of 7.9 GPM at a 45°F temperature rise. Venting is 2" or 3" PVC, CPVC or approved polypropylene to 65 or 150 equivalent feet, and system water pressure is rated 6 to 80 psi.

One naming note: the current product pages list NFC-250/175H and NFC-250/200H, while the 2021 service manual still covers the earlier names NFC-175H and NFC-200H for the same units. Owners should match codes and parts to the model shown on the rating plate.

Highlights

  • Fire-tube condensing combi with stainless steel heat exchanger
  • NFC-250/175H and NFC-250/200H, both 95.0% AFUE
  • DHW input to 210,000 BTU/h; 7.9 GPM at 45°F rise (installation manual)
  • 2" venting to 65 equivalent ft or 3" to 150 equivalent ft
  • Service manual naming NFC-175H/200H predates the current NFC-250 model names

Models

NFC-H Fire-Tube Combi models

One canonical page per model with input, output and efficiency kept separate.

CurrentSold in Canada
Input
13.3–175 MBH
Output (max)
—
AFUE
95 %

The Navien NFC-250/175H is the smaller NFC-H fire-tube combi: 13.3 to 175 MBH heating input, DHW input to 210,000 BTU/h, 7.9 GPM at a 45°F rise and 95.0% AFUE in a 141 lb stainless steel fire-tube cabinet.

Natural gasPropaneCombi
CurrentSold in Canada
Input
13.3–199.9 MBH
Output (max)
—
AFUE
95 %

The Navien NFC-250/200H is the top NFC-H fire-tube combi: 13.3 to 199.9 MBH heating input with DHW input to 210,000 BTU/h, 95.0% AFUE and 7.9 GPM DHW flow at a 45°F rise, in the same 141 lb cabinet as the 175H.

Natural gasPropaneCombi

Compare models in this series

Comparison of Navien NFC-250/175H and Navien NFC-250/200H
SpecificationNavien NFC-250/175HNavien NFC-250/200H
Heating input, minimum13.3 MBH13.3 MBH
Heating input, maximum175 MBH199.9 MBH
output-max——
Efficiency (AFUE)95 %95 %
turndown——
Max. equivalent vent length, 3"150 ft150 ft
Max. equivalent vent length, 2"65 ft65 ft
Weight141 lb141 lb

Read the full comparison: Navien NFC-250/175H vs NFC-250/200H →

Error codes and alerts

NFC-H Fire-Tube Combi alerts

  • E001front-panel display
  • E003front-panel display
  • E004front-panel display
  • E012front-panel display
  • E016front-panel display
  • E030front-panel display
  • E031front-panel display
  • E046front-panel display
  • E047front-panel display
  • E060front-panel display
  • E109front-panel display
  • E110front-panel display
  • E205front-panel display
  • E218front-panel display
  • E278front-panel display
  • E279front-panel display
  • E351front-panel display
  • E352front-panel display
  • E353front-panel display
  • E407front-panel display
  • E421front-panel display
  • E434front-panel display
  • E439front-panel display
  • E441front-panel display
  • E445front-panel display
  • E515front-panel display
  • E517front-panel display
  • E594front-panel display
  • E615front-panel display
  • E736front-panel display
  • E740front-panel display
  • E761front-panel display
  • E762front-panel display
  • E773front-panel display
  • E777front-panel display
  • E782front-panel display
  • E784front-panel display
  • E786front-panel display
  • E788front-panel display

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

What is different about a fire-tube combi?

In the NFC-H the burner fires into a stainless steel fire-tube heat exchanger, the design Navien markets for this combi series. Functionally it is still a condensing combi: one appliance provides space heating and on-demand domestic hot water.

How much hot water can the NFC-H deliver?

Navien's installation manual publishes 7.9 GPM of DHW flow at a 45°F temperature rise for the NFC-H models, with DHW input reaching 210,000 BTU/h. Actual delivery depends on incoming water temperature and the household's draw pattern.

Are NFC-175H and NFC-250/175H the same boiler?

The NFC-H service manual (Ver 1.0, Jan 2021) covers units named NFC-175H and NFC-200H, while current product pages call the same generation NFC-250/175H and NFC-250/200H. Match error codes and service steps to the model on the rating plate.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate