NTI Trinity TFT399

The NTI Trinity TFT399 is a discontinued wall-hung fire-tube condensing boiler: 39.9–399 MBH input with a 380 MBH heating capacity, a 330 MBH Net I=B=R rating and 95.4% thermal efficiency (AFUE not applicable) per the TFT I&O manual (99984535).

DiscontinuedHistorically in Canada

Key figures

Max input
399 MBH
Max CSA output
AFUE
95.4 %
Min input
39.9 MBH
Natural gasPropaneHeating-onlyresidentialcommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

NTI Trinity TFT399 in practice

The TFT399 is one of the eight wall-hung condensing models in NTI's discontinued Trinity TFT line, documented in the Trinity Tft 60-399 Installation and Operation Instructions (99984535, V.2024-04-08). Table 2-1 lists it at 39.9–399 MBH CSA input modulation with a 380 MBH DOE heating capacity and a 330 MBH Net I=B=R rating. The manual prints 95.4% for this size as thermal efficiency and notes that AFUE is not applicable above 299 MBH.

The model connects with 1-1/2" NPT male water connections and a 3/4" NPT male gas connection, and the manual specifies 4 in vent/air-inlet piping. The discontinued TFT page lists 4" runs up to 100 ft each side, a with-water weight of 250 lb and 6.4 gallons of boiler water content for this size. NTI lists the TFT under Discontinued and describes the current TFTN as built on the same platform with a redesigned control, so TFT owners and technicians rely on the 99984535 manual and the discontinued page's submittals.

Best suited to

  • Commercial loads up to 399 MBH where AFUE does not apply
  • Plants wanting the largest TFT in the 4" venting class
  • Cascade and common-vent installations at the top of the TFT line

Applicability and support

Model number
TFT399
Canadian availability
historical
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by NTI Boilers. Units are shown with every value; notes flag conflicting sources or missing figures.

NTI Trinity TFT399 specifications
SpecificationValueNote
Input
Input, minimum39.9 MBHPer the Trinity Tft 60-399 I&O manual (99984535), Table 2-1; the discontinued TFT page prints the same natural-gas row.
Input, maximum399 MBHPer the Trinity Tft 60-399 I&O manual (99984535), Table 2-1; the discontinued TFT page prints the same natural-gas row.
Output
DOE heating capacity380 MBHPer the TFT I&O manual (99984535), Table 2-1.
Net I=B=R rating330 MBHPer the TFT I&O manual (99984535), Table 2-1.
Efficiency
Thermal efficiency95.4 %The manual prints 95.4% as thermal efficiency for the TFT340/TFT399 and notes AFUE is not applicable above 299 MBH; the discontinued page repeats 95.4%.
Domestic hot water
Domestic hot waterHeating-only; pair with an indirect tank or separate water heater
Venting and air
Vent / air-inlet diameter4 inPer the TFT I&O manual, Table 2-1.
Vent / air-inlet length4" runs up to 100 ft each sidePer the discontinued TFT product page.
Physical and connections
Water connections1-1/2" NPT maleNPT male per the TFT I&O manual, Table 2-1.
Gas connection3/4" NPT maleNPT male per the TFT I&O manual, Table 2-1.
Weight, with water250 lbPer the TFT I&O manual, Table 2-1.
Boiler water content6.4 galPer the TFT I&O manual, Table 2-1.
Operating limits and other
Canada altitude derate10% derate at 2,000–4,500 ftPer the TFT I&O manual, Table 2-2.
FuelNatural gas or propaneThe discontinued TFT page prints a separate LP input row identical to the natural-gas row for this size.

Manuals

Alerts documented for this model

Services

Frequently asked questions

Is the TFT399 still available?

No. NTI lists the TFT series under Discontinued. The current TFTN line is described by NTI as built on the same platform as the TFT with a redesigned control.

What efficiency does the TFT399 have?

The TFT I&O manual (99984535) prints 95.4% for the TFT399 as thermal efficiency and notes AFUE is not applicable above 299 MBH.

What connections and venting does the TFT399 use?

1-1/2" NPT male water connections, a 3/4" NPT male gas connection and 4 in vent/air-inlet piping per the TFT I&O manual's Table 2-1.

Questions about the NTI Trinity TFT399?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate