NTI Boilers · Trinity TFT (discontinued)

NTI Trinity TFT60

The NTI Trinity TFT60 is a discontinued wall-hung fire-tube condensing boiler: 17–60 MBH input with a 56 MBH heating capacity, a 48 MBH Net I=B=R rating and 95% AFUE per the TFT I&O manual (99984535).

DiscontinuedHistorically in Canada

Key figures

Max input
60 MBH
Max CSA output
AFUE
95 %
Min input
17 MBH
Natural gasPropaneHeating-onlyresidentialcommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

NTI Trinity TFT60 in practice

The TFT60 is one of the eight wall-hung condensing models in NTI's discontinued Trinity TFT line, documented in the Trinity Tft 60-399 Installation and Operation Instructions (99984535, V.2024-04-08). Table 2-1 lists it at 17–60 MBH CSA input modulation with a 56 MBH DOE heating capacity and a 48 MBH Net I=B=R rating. The manual's 95% AFUE figure covers the TFT60 through the TFT285.

The model connects with 1" NPT male water connections and a 1/2" NPT male gas connection, and the manual specifies 2 or 3 in vent/air-inlet piping. The discontinued TFT page lists 2" or 3" runs up to 100 ft each side; on LP the 2" run is limited to 35 ft on the TFT60-85, a with-water weight of 110 lb and 3.2 gallons of boiler water content for this size. NTI lists the TFT under Discontinued and describes the current TFTN as built on the same platform with a redesigned control, so TFT owners and technicians rely on the 99984535 manual and the discontinued page's submittals.

Best suited to

  • Homes whose heat-loss calculation lands near the low end of the TFT range
  • Retrofits wanting the smallest TFT cabinet and 2" venting
  • Systems where 95% AFUE meets the efficiency target

Applicability and support

Model number
TFT60
Canadian availability
historical
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by NTI Boilers. Units are shown with every value; notes flag conflicting sources or missing figures.

NTI Trinity TFT60 specifications
SpecificationValueNote
Input
Input, minimum17 MBHPer the Trinity Tft 60-399 I&O manual (99984535), Table 2-1; the discontinued TFT page prints the same natural-gas row.
Input, maximum60 MBHPer the Trinity Tft 60-399 I&O manual (99984535), Table 2-1; the discontinued TFT page prints the same natural-gas row.
Output
DOE heating capacity56 MBHPer the TFT I&O manual (99984535), Table 2-1.
Net I=B=R rating48 MBHPer the TFT I&O manual (99984535), Table 2-1.
Efficiency
Efficiency (AFUE)95 %95% AFUE printed for the TFT60 through TFT285 in the manual's Table 2-1 and on the discontinued page.
Domestic hot water
Domestic hot waterHeating-only; pair with an indirect tank or separate water heater
Venting and air
Vent / air-inlet diameter2 or 3 inPer the TFT I&O manual, Table 2-1.
Vent / air-inlet length2" or 3" runs up to 100 ft each side; on LP the 2" run is limited to 35 ft on the TFT60-85Per the discontinued TFT product page.
Physical and connections
Water connections1" NPT maleNPT male per the TFT I&O manual, Table 2-1.
Gas connection1/2" NPT maleNPT male per the TFT I&O manual, Table 2-1.
Weight, with water110 lbPer the TFT I&O manual, Table 2-1.
Boiler water content3.2 galPer the TFT I&O manual, Table 2-1.
Operating limits and other
Canada altitude derate10% derate at 2,000–4,500 ftPer the TFT I&O manual, Table 2-2.
FuelNatural gas or propaneThe discontinued TFT page prints NG 17–60 MBH and LP 17.6–65 MBH input rows for the TFT60.

Manuals

Alerts documented for this model

Services

Frequently asked questions

Is the TFT60 still available?

No. NTI lists the TFT series under Discontinued. The current TFTN line is described by NTI as built on the same platform as the TFT with a redesigned control.

What efficiency does the TFT60 have?

The TFT I&O manual (99984535) and the discontinued page print 95% AFUE for the TFT60.

What connections and venting does the TFT60 use?

1" NPT male water connections, a 1/2" NPT male gas connection and 2 or 3 in vent/air-inlet piping per the TFT I&O manual's Table 2-1.

Questions about the NTI Trinity TFT60?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate