Patterson-Kelley · Error codes
Patterson-Kelley error codes and alerts
Identical code numbers can mean different things on different controllers, so every entry is tied to the documented series, controller and manual version. A code is never a diagnosis.
If you smell gas
- Stop what you are doing. Do not use phones, switches, matches or anything that can spark inside.
- Go outside and leave the door open behind you.
- Call the FortisBC 24-hour emergency line at 1-800-663-9911 or dial 911.
Only after that, call ROMA about the boiler. Official guidance: FortisBC gas leaks and odour.
Patterson-Kelley NURO control error reference (MODU-FIRE FD and THERMIFIC VELOX; Appendix C)
0
None. The table classifies it as No lockout/hold.…
Lockout
1
Unconfigured safety data. 1. If a New device, complete the device configuration procedure. 2. If fault repeats, replace the Sola. The table …
Lockout
2
Waiting for safety data verification. 1. If a Safety parameter requiring verification was changed then perform a Verification Process. The V…
Lockout
3
Internal fault: Hardware fault. The table classifies it as Hold (H).…
Details
4
Internal fault: Safety Relay key feedback error. The table classifies it as Hold (H).…
Details
5
Internal fault: Unstable power (DCDC) output. The table classifies it as Hold (H).…
Details
6
Internal fault: Invalid processor clock. The table classifies it as Hold (H).…
Details
7
Internal fault: Safety relay drive error. The table classifies it as Hold (H).…
Details
8
Internal fault: Zero crossing not detected. The table classifies it as Hold (H).…
Details
9
Internal fault: Flame bias out of range. The table classifies it as Hold (H).…
Details
10
Internal fault: Invalid Burner control state. The table classifies it as Lockout (L).…
Lockout
11
Int fault: Invalid Burner control state flag. The table classifies it as Lockout (L).…
Lockout
12
Internal fault: Safety relay drive cap short. The table classifies it as Hold (H).…
Details
13
Internal fault: PII shorted to ILK. The table classifies it as Hold/Lockout (H/L).…
Lockout
14
Internal fault: HFS shorted to LCI. The table classifies it as Hold/Lockout (H/L).…
Lockout
15
Int fault: Safety relay test failed fdback ON. 1. Reset the Control The table classifies it as Lockout (L).…
Lockout
16
Int fault: Safety relay test failed relay OFF. 2. If the problem persists, Replace the Sola The table classifies it as Lockout (L).…
Lockout
17
Int fault: Safety relay test fail relay not OFF. The table classifies it as Lockout (L).…
Lockout
18
Int fault: Safety relay test fail fdback not ON. The table classifies it as Lockout (L).…
Lockout
19
Internal fault: Safety RAM write. The table classifies it as Lockout (L).…
Lockout
20
Internal fault: Flame ripple and overflow. The table classifies it as Hold (H).…
Details
21
Int fault: Flame number of sample mismatch. The table classifies it as Hold (H).…
Details
22
Internal fault: Flame bias out of range. The table classifies it as Hold (H).…
Details
23
Int fault: Bias change since heat cycle start. The table classifies it as Hold (H).…
Details
24
Int fault: Spark voltage stuck low or high. The table classifies it as Hold (H).…
Lockout
25
Int fault: Spark voltage change too much during flame sensing time. The table classifies it as Hold (H).…
Lockout
26
Internal fault: Static flame ripple. The table classifies it as Hold (H).…
Details
27
Internal fault: Flame rod shorted to ground. The table classifies it as Hold (H).…
Lockout
28
Internal fault: A/D linearity test fails. The table classifies it as Hold (H).…
Details
29
Int fault: Flame bias cannot be set in range. The table classifies it as Hold (H).…
Details
30
Int fault: Flame bias shorted to adjacent pin. The table classifies it as Hold (H).…
Details
31
Int fault: SLO electronics unknown error. The table classifies it as Hold (H).…
Details
32
Internal fault: Safety Key 0. The table classifies it as Lockout (L).…
Lockout
33
Internal fault: Safety Key 1. The table classifies it as Lockout (L).…
Lockout
34
Internal fault: Safety Key 2. The table classifies it as Lockout (L).…
Lockout
35
Internal fault: Safety Key 3. The table classifies it as Lockout (L).…
Lockout
36
Internal fault: Safety Key 4. The table classifies it as Lockout (L).…
Lockout
37
Internal fault: Safety Key 5. The table classifies it as Lockout (L).…
Lockout
38
Internal fault: Safety Key 6. 1. Reset the Control The table classifies it as Lockout (L).…
Lockout
39
Internal fault: Safety Key 7. 2. If the problem persists, Replace the Sola The table classifies it as Lockout (L).…
Lockout
40
Internal fault: Safety Key 8. The table classifies it as Lockout (L).…
Lockout
41
Internal fault: Safety Key 9. The table classifies it as Lockout (L).…
Lockout
42
Internal fault: Safety Key 10. The table classifies it as Lockout (L).…
Lockout
43
Internal fault: Safety Key 11. The table classifies it as Lockout (L).…
Lockout
44
Internal fault: Safety Key 12. The table classifies it as Lockout (L).…
Lockout
45
Internal fault: Safety Key 13. The table classifies it as Lockout (L).…
Lockout
46
Internal fault: Safety Key 14. The table classifies it as Lockout (L).…
Lockout
47
Flame Rod to ground leakage. The table classifies it as Hold (H).…
Lockout
48
Static flame (not flickering). The table classifies it as Hold (H).…
Details
49
24VAC voltage low/high. The 24V ac power supply to the Sola is supplying incorrect voltage 1. Check the Burner Control connections. 2. Check…
Details
50
Modulation fault. Internal sub-system fault. The table classifies it as Hold (H).…
Details
51
Pump fault. 1. Review error messages for possible trends. The table classifies it as Hold (H).…
Details
52
Motor tachometer fault. 2. Correct possible problems. 3. If fault persists, replace Sola Burner control The table classifies it as Hold (H).…
Details
53
AC inputs phase reversed. 1. Check the Burner Control and display connections. 2. Check the Burner Control power supply and make sure that b…
Lockout
54
Safety GVT model ID Mismatch. The internal Safety GVT Model ID does not match the applications model ID 1. Reset the Control 2. If the probl…
Lockout
55
Application config data block CRC errors. 1. Reset the Control 2. If the problem persists, Replace the Sola The table classifies it as Locko…
Lockout
56
Modbus Heartbeat. The communication between the Nuro and the Sola has been lost. 1. Check the wiring connections between the Modbus terminal…
Details
58
Internal fault: HFS shorted to IAS. Internal Fault. The table classifies it as Lockout (L).…
Lockout
59
Internal Fault: Mux pin shorted. 1. Reset the control The table classifies it as Lockout (L).…
Lockout
60
Internal Fault: HFS shorted to LFS. 2. If fault repeats, replace the Sola The table classifies it as Lockout (L).…
Lockout
61
Anti short cycle. The table classifies it as Hold (H).…
Details
62
Fan speed not proved. 2. Check that the fan indicates proper RPM 3. Check for electrical noise sources The table classifies it as Hold (H).…
Details
63
LCI OFF. The table classifies it as Hold (H).…
Details
64
PII OFF. 4. If the fault persists, replace the Sola. 5. If the fault persists, replace the fan Unexpected error. Consult the factory The air…
Lockout
65
Airflow Switch OFF. 2. Check for proper airflow through the appliance. 3. Check airflow switches to assure proper functioning. 4. Check the …
Lockout
66
Airflow Switch ON. The air switch is closed when it should be open. 1. Check wiring and correct any possible shorts. 2. Check airflow switch…
Lockout
67
ILK OFF. 5. Reset and sequence the module; monitor the airflow status. 6. If code persists, replace the module. Unexpected error. Consult th…
Lockout
68
ILK ON. The table classifies it as Hold/Lockout (H/L).…
Lockout
69
Unexpected error 69 pilot test hold. The table classifies it as Hold (H).…
Details
70
Int fault 70. Wait for leakage test completion. 1. Internal Fault. Reset Module. 2. If fault repeats, replace module. The table classifies i…
Details
71
Input power frequency incorrect. The input power frequency is not within tolerance limits. 1. Check that the input power frequency matches t…
Lockout
78
Demand Lost in Run. 1. Check wiring and correct any possible errors. 2. If previous steps are correct and fault persists, replace the module…
Details
79
Outlet high limit. The OEM Maximum Boiler Outlet Temperature is exceeded. 1. Check settings for operation causing high temperatures. 2. Chec…
Lockout
80
DHW high limit. temperatures. 2. Check DHW pump for proper operation. The table classifies it as Hold/Lockout (H/L).…
Lockout
81
Delta T limit. 3. Check DHW sensor for proper operation. 1. Check Inlet and Outlet sensors and pump circuits for proper operation. 2. Rechec…
Lockout
82
Stack limit. possible errors. 2. Check for fouled heat exchanger. 3. Check for proper combustion 4. Check for proper fan speed 5. Check for …
Lockout
83
Delta T exchanger/outlet limit. The table classifies it as Hold/Lockout (H/L).…
Lockout
84
Delta T inlet/exchanger limit. persists, replace the module. The inlet sensor temperature is higher than the outlet temperature sensor indic…
Lockout
85
Inlet/outlet inversion limit. flow. The table classifies it as Hold/Lockout (H/L).…
Lockout
86
Exchanger/outlet inversion limit. 1. Check for proper system piping. 2. Check pumping system for proper flow The outlet temperature is risin…
Lockout
87
Inlet/exchanger inversion limit. The table classifies it as Hold/Lockout (H/L).…
Lockout
88
Outlet T-rise limit. indicating insufficient flow through the boiler. 1. Check for proper flow through the boiler. 2. Check for proper boile…
Lockout
89
Exchanger T-rise limit. fast indicating insufficient flow through the boiler. 1. Check for proper flow through the boiler. 2. Check for prop…
Lockout
90
Heat exchanger high limit. The temperature of the Heat Exchanger sensor has exceeded its limit. 1. Check settings for operation causing high…
Lockout
91
Inlet sensor fault. 1. Check wiring and correct any possible errors. 2. Replace the Inlet sensor. 3. If previous steps are correct and fault…
Details
92
Outlet sensor fault. 1. Check wiring and correct any possible errors. 2. Replace the Outlet sensor. 3. If previous steps are correct and fau…
Details
93
DHW sensor fault. 2. Replace the DHW sensor. 3. If previous steps are correct and fault persists, replace the module. The table classifies i…
Details
94
Header sensor fault. 1. Check wiring and correct any possible errors. 2. Replace the header sensor. 3. If previous steps are correct and fau…
Details
95
Stack sensor fault. 1. Check wiring and correct any possible errors. 2. Replace the stack sensor. 3. If previous steps are correct and fault…
Details
96
Outdoor sensor fault. 1. Check wiring and correct any possible errors. 2. Replace the outdoor sensor. 3. If previous steps are correct and f…
Details
97
Internal Fault: A2D mismatch. The table classifies it as Lockout (L).…
Lockout
98
Internal Fault: Exceeded VSNSR voltage. 1. Reset the Control 2. If the problem persists, Replace the Sola The table classifies it as Lockout…
Lockout
99
Int Fault: Exceeded 28V voltage tolerance. The table classifies it as Lockout (L).…
Lockout
100
Pressure Sensor Fault. 1. Ensure the Nuro control has proper software. 2. Ensure the Sola Control is correct. 3. If the problem persists, re…
Details
101
Heat exchanger sensor fault. The table classifies it as Hold (H).…
Details
105
Flame detected out of sequence. 2. Make sure that the flame detector is wired to the correct terminal. 3. Make sure the F & G wires are prot…
Lockout
106
Flame lost in Main Flame Establish Period. 5. Reset and sequence the Sola, if code reappears, replace the module. 1. Check Gas Valve for pro…
Lockout
107
Flame lost early in run. The table classifies it as Lockout (L).…
Lockout
108
Flame lost in run. The table classifies it as Lockout (L).…
Lockout
109
Ignition failed. 3. Check fuel pressure. 4. Check ignition transformer electrode, flame detector, or flame rod. The table classifies it as L…
Lockout
110
Ignition failure occurred. Holding for ignition recycle The table classifies it as Hold (H).…
Lockout
111
Flame current lower than WEAK threshold. Internal hardware test. If condition persists replace the Sola The table classifies it as Hold (H).…
Lockout
112
Pilot test flame timeout. 1. Ensure the Nuro control has proper software. 2. Ensure the Sola Control is correct. 3. If the problem persists,…
Lockout
113
Flame circuit timeout. Flame sensed during Initiate or off cycle, Sola will hold 240 seconds, if error is present after 240 seconds, lockout…
Lockout
122
Lightoff rate proving failed. 1. Check fan wiring and correct any potential The table classifies it as Lockout (L).…
Lockout
123
Purge rate proving failed. wiring errors. 2. Check that the fan indicates proper RPM 3. Check for electrical noise sources 4. If the fault p…
Lockout
124
High fire switch OFF. The table classifies it as Hold (H).…
Details
125
High fire switch stuck ON. 1. Ensure the Nuro control has proper software. 2. Ensure the Sola Control is correct. The table classifies it as…
Details
126
Low fire switch OFF. The table classifies it as Hold (H).…
Details
127
Low fire switch stuck ON. 3. If the problem persists, replace the Sola 1. Check fan wiring and correct any potential The table classifies it…
Lockout
128
Fan speed failed during prepurge. The table classifies it as Hold/Lockout (H/L).…
Lockout
129
Fan speed failed during preignition. wiring errors. The table classifies it as Hold/Lockout (H/L).…
Lockout
130
Fan speed failed during ignition. The table classifies it as Hold/Lockout (H/L).…
Lockout
131
Fan movement detected during standby. The table classifies it as Hold (H).…
Details
132
Fan speed failed during run. 2. Check that the fan indicates proper RPM 3. Check for electrical noise sources 4. If the fault persists, repl…
Details
136
Airflow Switch failed to close. 1. Check wiring and correct any possible open circuit. 2. Check for proper airflow through the appliance. 3.…
Details
137
ILK failed to close. airflow status. 6. If code persists, replace the module. 1. Ensure the Nuro control has proper software. 2. Ensure the …
Details
143
Internal fault: Flame bias out of range 1. The table classifies it as Lockout (L).…
Lockout
144
Internal fault: Flame bias out of range 2. The table classifies it as Lockout (L).…
Lockout
145
Internal fault: Flame bias out of range 3. The table classifies it as Lockout (L).…
Lockout
146
Internal fault: Flame bias out of range 4. The table classifies it as Lockout (L).…
Lockout
147
Internal fault: Flame bias out of range 5. 1. Reset the Control 2. If the problem persists, Replace the Sola OEM Specific The table classifi…
Lockout
148
Internal fault: Flame bias out of range 6. The table classifies it as Lockout (L).…
Lockout
149
Flame detected. 1. Holds if flame detected during Safe Start check up to Flame Establishing period. The table classifies it as Hold/Lockout …
Lockout
150
Flame not detected. OEM Specific 1. Sequence returns to standby and restarts sequence at the beginning of Purge after the HF switch opens. 2…
Lockout
151
High fire switch ON. The table classifies it as Hold/Lockout (H/L).…
Lockout
152
Combustion pressure ON. The table classifies it as Hold/Lockout (H/L).…
Lockout
153
Combustion Pressure Off. 1. Ensure the Nuro control has proper software. The table classifies it as Hold or Lockout (H or L).…
Lockout
154
Purge Fan switch On. 2. Ensure the Sola Control is correct. The table classifies it as Hold or Lockout (H or L).…
Lockout
155
Purge Fan switch Off. 3. If the problem persists, replace the Sola The table classifies it as Hold (H).…
Details
155
Purge fan switch OFF. The table classifies it as Hold/Lockout (H/L).…
Lockout
156
Combustion pressure and Flame ON. The table classifies it as Hold/Lockout (H/L).…
Lockout
157
Combustion pressure and Flame OFF. 1. Ensure the Nuro control has proper software. 2. Ensure the Sola Control is correct. 3. If the problem …
Lockout
158
Main valve ON. OEM Specific The table classifies it as Lockout (L).…
Lockout
159
Main valve OFF. 1. Check Main Valve terminal wiring and correct any errors. 2. Reset and sequence the module. If fault persist, replace the …
Lockout
160
Ignition ON. OEM Specific The table classifies it as Lockout (L).…
Lockout
161
Ignition OFF. 1. Check Ignition terminal wiring and correct any errors. 2. Reset and sequence the module. If fault persist, replace the modu…
Lockout
162
Pilot valve ON. OEM Specific The table classifies it as Lockout (L).…
Lockout
163
Pilot valve OFF. 1. Check Pilot Valve terminal wiring and correct any errors. 2. Reset and sequence the module. If fault persist, replace th…
Lockout
164
Block intake ON. 1. Ensure the Nuro control has proper software. The table classifies it as Lockout (L).…
Lockout
165
Block intake OFF. 2. Ensure the Sola Control is correct. 3. If the problem persists, replace the Sola The table classifies it as Lockout (L)…
Lockout
172
Main relay feedback incorrect. The table classifies it as Lockout (L).…
Lockout
173
Pilot relay feedback incorrect. The table classifies it as Lockout (L).…
Lockout
174
Safety relay feedback incorrect. Internal Fault. 1. Check wiring and correct any faults The table classifies it as Lockout (L).…
Lockout
175
Safety relay open. The table classifies it as Lockout (L).…
Lockout
176
Main relay ON at safe start check. 2. Reset Module. 3. If fault repeats, replace module. The table classifies it as Lockout (L).…
Lockout
177
Pilot relay ON at safe start check. The table classifies it as Lockout (L).…
Lockout
178
Safety relay ON at safe start check. The table classifies it as Lockout (L).…
Lockout
184
Invalid BLOWER/HSI output setting. The table classifies it as Lockout (L).…
Lockout
185
Invalid Delta T limit enable setting. The table classifies it as Lockout (L).…
Lockout
186
Invalid Delta T limit response setting. The table classifies it as Lockout (L).…
Lockout
187
Invalid DHW high limit enable setting. The table classifies it as Lockout (L).…
Lockout
188
Invalid DHW high limit response setting. The table classifies it as Lockout (L).…
Lockout
189
Invalid Flame sensor type setting. The table classifies it as Lockout (L).…
Lockout
190
Invalid interrupted air switch enable setting. The table classifies it as Lockout (L).…
Lockout
191
Invalid air switch start check enable setting. The table classifies it as Lockout (L).…
Lockout
192
Invalid igniter on during setting. 1. Ensure the boiler control touchscreen has The table classifies it as Lockout (L).…
Lockout
193
Invalid ignite failure delay setting. proper software. The table classifies it as Lockout (L).…
Lockout
194
Invalid ignite failure response setting. 2. Recycle power to the boiler control The table classifies it as Lockout (L).…
Lockout
195
Invalid ignite failure retries setting. 3. If fault repeats, verify electrical grounding. The table classifies it as Lockout (L).…
Lockout
196
Invalid ignition source setting. 4. If fault repeats, replace Sola The table classifies it as Lockout (L).…
Lockout
197
Invalid interlock open response setting. The table classifies it as Lockout (L).…
Lockout
198
Invalid interlock start check setting. The table classifies it as Lockout (L).…
Lockout
199
Invalid LCI enable setting. The table classifies it as Lockout (L).…
Lockout
200
Invalid lightoff rate setting. The table classifies it as Lockout (L).…
Lockout
201
Invalid lightoff rate proving setting. The table classifies it as Lockout (L).…
Lockout
202
Invalid Main Flame Establishing Period time. The table classifies it as Lockout (L).…
Lockout
203
Invalid MFEP flame failure response setting. The table classifies it as Lockout (L).…
Lockout
204
Invalid NTC sensor type setting. The table classifies it as Lockout (L).…
Lockout
205
Invalid Outlet high limit response setting. The table classifies it as Lockout (L).…
Lockout
206
Invalid Pilot Flame Establish Period setting. The table classifies it as Lockout (L).…
Lockout
207
Invalid PII enable setting. The table classifies it as Lockout (L).…
Lockout
208
Invalid pilot test hold setting. The table classifies it as Lockout (L).…
Lockout
209
Invalid Pilot type setting. The table classifies it as Lockout (L).…
Lockout
210
Invalid Postpurge time setting. The table classifies it as Lockout (L).…
Lockout
211
Invalid Power up with lockout setting. The table classifies it as Lockout (L).…
Lockout
212
Invalid Preignition time setting. The table classifies it as Lockout (L).…
Lockout
213
Invalid Prepurge rate setting. The table classifies it as Lockout (L).…
Lockout
214
Invalid Prepurge time setting. The table classifies it as Lockout (L).…
Lockout
215
Invalid Purge rate proving setting. The table classifies it as Lockout (L).…
Lockout
216
Invalid Run flame failure response setting. The table classifies it as Lockout (L).…
Lockout
217
Invalid Run stabilization time setting. The table classifies it as Lockout (L).…
Lockout
218
Invalid Stack limit enable setting. The table classifies it as Lockout (L).…
Lockout
219
Invalid Stack limit response setting. The table classifies it as Lockout (L).…
Lockout
220
Unconfigured Delta T limit setpoint setting. The table classifies it as Lockout (L).…
Lockout
221
Unconfigured DHW high limit setpoint setting. The table classifies it as Lockout (L).…
Lockout
222
Unconfigured Outlet high limit setpoint. The table classifies it as Lockout (L).…
Lockout
223
Unconfigured Stack limit setpoint setting. The table classifies it as Lockout (L).…
Lockout
224
Invalid DHW demand source setting. The table classifies it as Lockout (L).…
Lockout
225
Invalid Flame threshold setting. The table classifies it as Lockout (L).…
Lockout
226
Invalid Outlet high limit setpoint setting. The table classifies it as Lockout (L).…
Lockout
227
Invalid DHW high limit setpoint setting. The table classifies it as Lockout (L).…
Lockout
228
Invalid Stack limit setpoint setting. The table classifies it as Lockout (L).…
Lockout
229
Invalid Modulation output setting. The table classifies it as Lockout (L).…
Lockout
230
Invalid CH demand source setting. The table classifies it as Lockout (L).…
Lockout
231
Invalid Delta T limit delay setting. The table classifies it as Lockout (L).…
Lockout
232
Invalid Pressure sensor type setting. The table classifies it as Lockout (L).…
Lockout
233
Invalid IAS closed response setting. 1. Ensure the boiler control touchscreen has The table classifies it as Lockout (L).…
Lockout
234
Invalid Outlet high limit enable setting. proper software. The table classifies it as Lockout (L).…
Lockout
235
Invalid Outlet connector type setting. 2. Recycle power to the boiler control The table classifies it as Lockout (L).…
Lockout
236
Invalid Inlet connector type setting. 3. If fault repeats, verify electrical grounding. The table classifies it as Lockout (L).…
Lockout
237
Invalid DHW connector type setting. 4. If fault repeats, replace Sola The table classifies it as Lockout (L).…
Lockout
238
Invalid Stack connector type setting. The table classifies it as Lockout (L).…
Lockout
239
Invalid S2 (J8-6) connector type setting. The table classifies it as Lockout (L).…
Lockout
240
Invalid S5 (J8-11) connector type setting. The table classifies it as Lockout (L).…
Lockout
241
Exch sensor not allowed with stack setting. The table classifies it as Lockout (L).…
Lockout
242
Invalid DHW auto detect configuration. The table classifies it as Lockout (L).…
Lockout
243
Invalid UV Parameter Setting. The table classifies it as Lockout (L).…
Lockout
244
Internal fault: Safety relay test invalid state. The table classifies it as Lockout (L).…
Lockout
245
Invalid Outlet type setting for T- rise. The table classifies it as Lockout (L).…
Lockout
246
4-20mA not for modulat and setpoint control. The table classifies it as Lockout (L).…
Lockout
247
Invalid ILK bounce detection enable. The table classifies it as Lockout (L).…
Lockout
248
Invalid forced recycle interval. The table classifies it as Lockout (L).…
Lockout
249
STAT not dmd srce when Rem Stat enbled. The table classifies it as Lockout (L).…
Lockout
250
Invalid Fan speed error response. The table classifies it as Lockout (L).…
Lockout
251
Lead drop-stage on error setting incorrect. The table classifies it as Lockout (L).…
Lockout
252
Invalid Line frequency setting. The table classifies it as Lockout (L).…
Lockout
253
Lead Lag mod sensr invalid w setpnt source. The table classifies it as Lockout (L).…
Lockout
254
Lead Lag mod sensr invalid w local stpnt src. The table classifies it as Lockout (L).…
Lockout
255
Lead Lag mod sensr invalid w local mod src. The table classifies it as Lockout (L).…
Lockout
256
interaction enable setting is not allowed. The table classifies it as Lockout (L).…
Lockout
257
I enable not match nghbor stckflt sting. The table classifies it as Lockout (L).…
Lockout
258
ID mst be nonzero if intrction enabled. The table classifies it as Lockout (L).…
Lockout
259
Mod output must be fan. The table classifies it as Lockout (L).…
Lockout
260
no flap is set but flap input is enrgizd. The table classifies it as Lockout (L).…
Lockout
261
Neighbor burner control blower fault. The table classifies it as Lockout (L).…
Lockout
262
Blower fault detected during flap test. The table classifies it as Lockout (L).…
Lockout
263
Invalid DHW demand temperature. The table classifies it as Lockout (L).…
Lockout
264
Invalid preferred outlet high limit. The table classifies it as Lockout (L).…
Lockout
265
Invalid preferred lightoff rate. The table classifies it as Lockout (L).…
Lockout
266
Invalid preferred stack limit rate. proper software. 2. Recycle power to the boiler control 3. If fault repeats, verify electrical grounding…
Lockout
267
Invalid modbus timeout setting. 4. If fault repeats, replace Sola 1. Ensure the boiler control touchscreen has proper software. The table cl…
Lockout
268
Modbus. The table classifies it as Lockout (L).…
Lockout
269
Invalid Modbus blower output setting. 2. Recycle power to the boiler control…
Details
270
Invalid flow switch enable setting. 3. If fault repeats, verify electrical grounding.…
Details
271
Invalid flow switch debounce time setting. 4. If fault repeats, replace Sola…
Details
272
Flow Switch Not Closed. The flow switch was open when it should have been closed. 1. Check the pump 2. Check for flow obstructions…
Details
273
Invalid LFS Flow. 1. Ensure the boiler control touchscreen has…
Details
274
Invalid Flow Blocked. proper software. 2. Recycle power to the boiler control 3. If fault repeats, verify electrical grounding. 4. If fault …
Details
275
Damper End Switch Open. The damper end switch failed to make indicating the inlet air damper is closed when it should be open. 1. If an air …
Details
276
Damper End Switch Closed. The damper end switch failed to open indicating an inoperative damper system. 1. If an air inlet damper is used, c…
Details
277
Invalid Damper Enable. 1. Ensure the boiler control touchscreen has…
Details
278
Invalid Damper Time. proper software.…
Details
279
Invalid Damper PII. 2. Recycle power to the boiler control 3. If fault repeats, verify electrical grounding. 4. If fault repeats, replace So…
Details
280
Damper Lost in Run. The damper end switch changed to OFF while the boiler was firing indicating the inlet air damper is closed when it shoul…
Details
10000
DHW sensor open. The DHW sensor is indicating an open circuit 1. Check the wiring to the DHW sensor. 2. Check the connection to the controls…
Details
10001
Unknown DHW mode. The control is set for a DHW Mode that does not exist. 1. Power the module off and on to reboot the control. 2. If the pro…
Details
10002
Header sensor open circuit. A header sensor is not detected. Check the wiring to the header sensor Replace the header sensor…
Details
10003
Header sensor short circuit. The header sensor is indicating a short. 1. Check the wiring to the header sensor. 2. Replace the header sensor…
Details
10004
Outdoor Air sensor open circuit. The outdoor air sensor is not detected. 1. Check the wiring to the outdoor air sensor. 2. Replace the outdo…
Details
10005
Outdoor Air sensor short circuit. The outdoor air sensor is indicating a short. 1. Check the wiring to the outdoor air sensor. 2. Replace th…
Details
10006
DHW sensor short circuit. The DHW sensor is indicating a short. 1. Check the wiring to the DHW sensor. 2. Replace the DHW sensor.…
Details
10007
Boiler did not start in the allotted time. 1. Check the log to determine the cause of the failure to start. 2. Check the Start Time Allowed …
Lockout
10008
Unknown PK Command. Parameter The manual reset high limit has tripped. The table classifies it as Lockout (L).…
Lockout
10009
High Temperature Limit. 1. Check settings for operation causing high temperatures. 2. Check boiler pump for proper operation. 3. Check for p…
Lockout
10010
Low Water Limit. the boiler. The Low water level device has tripped indicating insufficient water level in the boiler. 1. Check for proper w…
Lockout
10011
High Gas Limit. The high gas limit switch has tripped. 1. Check for proper gas valve adjustment. 2. Check for proper gas valve operation. 3.…
Lockout
10012
Low Gas Limit. The low gas limit switch has tripped. 1. Check for proper gas inlet pressure at all firing rates. 2. Check for proper wiring.…
Lockout
10013
High Back Pressure Limit. The High Back Pressure Switch has tripped indicating excessive Flue Back Pressure. 1. Check for obstructions in th…
Details
10014
Start Interlock1 Open. The Start Interlock 1 terminals are open while the boiler is attempting to run. 1. Check the devices attached to Star…
Details
10015
Start Interlock 2 Open. The Start Interlock 2 terminals are open while the boiler is attempting to run. 1. Check the devices attached to Sta…
Details
10016
Unknown ILK error. The Interlock Control Circuit is Open while the boiler is attempting to run. The control cannot determine the individual …
Details
10017
Unknown LCI error. boiler is attempting to run. The control cannot determine the individual switch that is causing The table classifies it a…
Lockout
10018
Unkown DHW Autoboost Selection. this. The control is set for a (Insert Selection, The table classifies it as Hold (H).…
Details
10019
Unknown DHW Tank Setpoint Source. The table classifies it as Hold (H).…
Details
10020
Unknown DHW Tank Pmp Cntrl Method. Source, Method, Type) selection that does not The table classifies it as Hold (H).…
Details
10021
Unknown DHW Pump Control Method. exist. The table classifies it as Hold (H).…
Details
10022
Unknown DHW Pump Type. 1. Power the module off and on to reboot the The table classifies it as Hold (H).…
Details
10023
Unknown DWH Setpoint Source. control. The table classifies it as Hold (H).…
Details
10024
Unknown CH Mode. The table classifies it as Hold (H).…
Details
10025
Unknown CH Setpoint Source. 2. If the problem persists, replace the NURO The analog input is above or below the The table classifies it as H…
Details
10026
Analog Input out of Range. allowable analog input. 1. Check Analog input signal for proper value. 2. Check Analog input signal wiring for pr…
Details
10027
Unknown CH Boiler Pmp Cntrl Method. connection. The control is set for a (Insert Selection, Source, Method, Type) selection that does not Th…
Details
10028
Unknown CH System Pmp Cntrl Method. The table classifies it as Hold (H).…
Details
10029
Unkown CH Pump Type. exist. The table classifies it as Hold (H).…
Details
10030
Unknown CH Demand Source. 1. Power the module off and on to reboot the control. 2. If the problem persists, replace the NURO The table class…
Details
10031
cannot write REMOTESTATE. The table classifies it as Hold (H).…
Details
10032
cannot write BURNERCYCLECOUNT. The table classifies it as Hold (H).…
Details
10033
cannot write BURNERRUNTIME. The table classifies it as Hold (H).…
Details
10034
cannot write RELAYACYCLECOUNT. The table classifies it as Hold (H).…
Details
10035
cannot write RELAYBCYCLECOUNT. The table classifies it as Hold (H).…
Details
10036
cannot write RELAYCCYCLECOUNT. The table classifies it as Hold (H).…
Details
10037
cannot write ANTISHORTCYCLE. The table classifies it as Hold (H).…
Details
10038
cannot write ALARMSILENCETIME. The table classifies it as Hold (H).…
Details
10039
cannot write POWERUPWITHLOCKOUT. The table classifies it as Hold (H).…
Details
10040
cannot write MODULATIONOUTPUT. The table classifies it as Hold (H).…
Details
10041
cannot write MAXMODULATIONRATE. The table classifies it as Hold (H).…
Details
10042
cannot write DHWMAXMODULATIONRAT. The table classifies it as Hold (H).…
Details
10043
cannot write MINMODULATIONRATE. The table classifies it as Hold (H).…
Details
10044
cannot write PREPURGERATE. The table classifies it as Hold (H).…
Details
10045
cannot write LIGHTOFFRATE. The control is unable to write the (Insert Parameter) variable to the SOLA The table classifies it as Hold (H).…
Details
10046
cannot write POSTPURGERATE. The table classifies it as Hold (H).…
Details
10047
cannot write BURNERSWITCH. 1. Power the module off and on to reboot the control. The table classifies it as Hold (H).…
Details
10048
cannot write FIRINGRATECONTROL. The table classifies it as Hold (H).…
Details
10049
cannot write STANDBYRATE. 2. If the problem persists, contact the factory for assistance replacing the SOLA. The table classifies it as Hold…
Details
10050
cannot write DISABLECHMODE. The table classifies it as Hold (H).…
Details
10051
cannot write IGNITIONSOURCE. The table classifies it as Hold (H).…
Lockout
10052
cannot write HISOUTPUT. The table classifies it as Hold (H).…
Details
10053
cant write IGNITORONDURING12. The table classifies it as Hold (H).…
Lockout
10054
cannot write PILOTTYPE. The table classifies it as Hold (H).…
Details
10055
cannot write FLAMESENSORTYPE. The table classifies it as Hold (H).…
Details
10056
cannot write PURGERATEPROVING. The table classifies it as Hold (H).…
Details
10057
cannot write LIGHTOFFPROVING. The table classifies it as Hold (H).…
Details
10058
cannot write PREPURGETIME. The table classifies it as Hold (H).…
Details
10059
cannot write PREIGNITIONTIME. The table classifies it as Hold (H).…
Lockout
10060
cannot write TIMETOESTABLISHFLAME. The table classifies it as Hold (H).…
Details
10061
cant write MAINFLAMEESTABLISHTIME. The table classifies it as Hold (H).…
Details
10062
cannot write RUNSTABILAZTIONTIME. The table classifies it as Hold (H).…
Details
10063
cannot write POSTPURGETIME. The table classifies it as Hold (H).…
Details
10064
cannot write INTERLOCKSTARTCHECK. The table classifies it as Hold (H).…
Details
10065
cannot write INTERLOCKOPENRESPONSE. The control is unable to write the (Insert Parameter) variable to the SOLA The table classifies it as Ho…
Details
10066
cannot write IGNITEFAILURERESPONSE. The table classifies it as Hold (H).…
Lockout
10067
cannot write IGNITEFAILURERETRIES. 1. Power the module off and on to reboot the control. The table classifies it as Hold (H).…
Lockout
10068
cannot write IGNITEFAILUREDELAY. The table classifies it as Hold (H).…
Lockout
10069
cant writ MAINFLAMEFAILURERESPONSE. 2. If the problem persists, contact the factory for The table classifies it as Hold (H).…
Details
10070
cant write RUNFLAMEFAILURERESPONSE. assistance replacing the SOLA. The table classifies it as Hold (H).…
Details
10071
cannot write AIRSWITCHMODE. The table classifies it as Hold (H).…
Details
10072
cannot write LCIENABLE. The table classifies it as Hold (H).…
Details
10073
cannot write PIIINTERLOCK. The table classifies it as Hold (H).…
Details
10074
cannot write FLAMETHRESHOLD. The table classifies it as Hold (H).…
Details
10075
cannot write ILKDEBOUNCE. The table classifies it as Hold (H).…
Details
10076
cannot write FORCERECYCLETIME. The table classifies it as Hold (H).…
Details
10077
cant write FANSPEEDERRORRESPONSE. The table classifies it as Hold (H).…
Details
10078
cannot write ABSMAXFANSPEED. The table classifies it as Hold (H).…
Details
10079
cannot write ABSMINFANSPEED. The table classifies it as Hold (H).…
Details
10080
cannot write PWMFREQUENCY. The table classifies it as Hold (H).…
Details
10081
cant write NUMBERHALLSWITCHES. The table classifies it as Hold (H).…
Details
10082
cannot write FANRAMPSPEEDUP. The table classifies it as Hold (H).…
Details
10083
cant write FANRAMPSPEEDDOWN. The table classifies it as Hold (H).…
Details
10084
cannot write FANGAINSPEEDUP. The table classifies it as Hold (H).…
Details
10085
cannot write FANGAINSPEEDDOWN. The table classifies it as Hold (H).…
Details
10086
cannot write FANMINDUTYCYCLE. The table classifies it as Hold (H).…
Details
10087
cannot write SETRELAYA. The table classifies it as Hold (H).…
Details
10088
cannot write RELAYAAUTO. The table classifies it as Hold (H).…
Details
10089
cannot write RELAYAOVERRUN. The table classifies it as Hold (H).…
Details
10090
cant PUMPFREEZEPROTECTIONOVERRUN. The table classifies it as Hold (H).…
Details
10091
cannot write OFFDHWPUMP. The table classifies it as Hold (H).…
Details
10092
cannot write SETRELAYB. The table classifies it as Hold (H).…
Details
10093
cannot write RELAYBAUTO. The table classifies it as Hold (H).…
Details
10094
cannot write RELAYBOVERRUN. The table classifies it as Hold (H).…
Details
10095
cannot write OFFAUX1PUMP. The table classifies it as Hold (H).…
Details
10096
cannot write SETRELAYC. The table classifies it as Hold (H).…
Details
10097
cannot write RELAYCAUTO. The table classifies it as Hold (H).…
Details
10098
cannot write RELAYCOVERRUN. The table classifies it as Hold (H).…
Details
10099
cannot write DISABLEPUMPEXERSIZE. The table classifies it as Hold (H).…
Details
10100
cannot write PUMPEXERSIZETIME. The table classifies it as Hold (H).…
Details
10101
cannot write RELAYASTARTDELAY. The table classifies it as Hold (H).…
Details
10102
cannot write RELAYBSTARTDELAY. The table classifies it as Hold (H).…
Details
10103
cannot write RELAYCSTARTDELAY. The table classifies it as Hold (H).…
Details
10104
cannot write RELAYAOPTIONS1. The table classifies it as Hold (H).…
Details
10105
cannot write RELAYAOPTIONS2. The table classifies it as Hold (H).…
Details
10106
cannot write RELAYBOPTIONS1. The table classifies it as Hold (H).…
Details
10107
cannot write RELAYBOPTIONS2. The table classifies it as Hold (H).…
Details
10108
cannot write RELAYCOPTIONS1. The table classifies it as Hold (H).…
Details
10109
cannot write RELAYCOPTIONS2. The table classifies it as Hold (H).…
Details
10110
cannot write ENABLEANNUNCIATORS. The table classifies it as Hold (H).…
Details
10111
cannot write ANN2LOCATION. The table classifies it as Hold (H).…
Details
10112
cannot write ANN2STRING. The table classifies it as Hold (H).…
Details
10113
cannot write ANN3LOCATION. The table classifies it as Hold (H).…
Details
10114
cannot write ANN3STRING. The table classifies it as Hold (H).…
Details
10115
cannot write ANN4LOCATION. The table classifies it as Hold (H).…
Details
10116
cannot write ANN4STRING. The table classifies it as Hold (H).…
Details
10117
cannot write ANN5LOCATION. The table classifies it as Hold (H).…
Details
10118
cannot write ANN5STRING. The table classifies it as Hold (H).…
Details
10119
cannot write ANN6LOCATION. The table classifies it as Hold (H).…
Details
10120
cannot write ANN6STRING. The table classifies it as Hold (H).…
Details
10121
cannot write ANN7LOCATION. The table classifies it as Hold (H).…
Details
10122
cannot write ANN7STRING. The table classifies it as Hold (H).…
Details
10123
cannot write ANN8LOCATION. The table classifies it as Hold (H).…
Details
10124
cannot write ANN8STRING. The control is unable to write the (Insert The table classifies it as Hold (H).…
Details
10125
cannot write PIISTRING. Parameter) variable to the SOLA The table classifies it as Hold (H).…
Details
10126
cannot write LCISTRING. 1.Power the module off and on to reboot the control. 2. If the problem persists, contact the factory for assistance …
Details
10127
cannot write ILKSTRING. The table classifies it as Hold (H).…
Details
10128
cannot write DISABLEDHW. 2. If the problem persists, contact the factory for assistance replacing the SOLA. The table classifies it as Hold …
Details
10129
cannot write OUTLETHIGHLIMIT. The table classifies it as Hold (H).…
Details
10130
cannot write RESPONSEHIGHLIMIT. The table classifies it as Hold (H).…
Details
10131
cannot write STACKLIMITENABLE. The table classifies it as Hold (H).…
Details
10132
cannot write STACKLIMIT. The table classifies it as Hold (H).…
Details
10133
cannot write STACKLIMITREPOSONSE. The table classifies it as Hold (H).…
Details
10134
cannot write STACKLIMITDELAYTIME. The table classifies it as Hold (H).…
Details
10135
cannot write DELTATENABLE. The table classifies it as Hold (H).…
Details
10136
cannot write DELTATLIMIT. The table classifies it as Hold (H).…
Details
10137
cannot write DELTATRESPONSE. The table classifies it as Hold (H).…
Details
10138
cannot write DELTATDELAY. The table classifies it as Hold (H).…
Details
10139
cannot write DHWLIMITENABLE. 1. The Alert Handler has been updated The table classifies it as Hold (H).…
Details
10140
cannot write CHSLOWSTART. The table classifies it as Hold (H).…
Details
10141
cannot write OUTLETTRISEENABLE. 2. To complete the process, you must cycle power Modulation Start Offset The table classifies it as Hold (H)…
Details
10142
cannot write OUTLETTRISE. The table classifies it as Hold (H).…
Details
10143
cannot write OUTLETTRISEDELAY. The table classifies it as Hold (H).…
Details
10144
cannot write OUTLETHIGHLIMITENABLE. Modulation Recycle Offset The Maximum Delta T between the boiler inlet and outlet sensors is exceeded. T…
Details
10145
cannot write DELTATRETYRLIMIT. The table classifies it as Hold (H).…
Details
10146
cannot write DELTATRATELIMITENABLE. The table classifies it as Hold (H).…
Details
10147
cannot write DELTATINVERSETIME. 1. Check the pump and system for proper flow through the boiler. 2. Ensure all water filters and strainers a…
Details
10148
cant writ DELTATINVERSELIMITRESPONSE. The table classifies it as Hold (H).…
Details
10149
cannot write DELTATHXOUTLET. The table classifies it as Hold (H).…
Details
10150
cant write EXCHANGERTRISEENABLE. The table classifies it as Hold (H).…
Details
10151
cant write EXCHANGERTRISERESPONCE. of debris. 3. Check the inlet and outlet sensors for proper function. 4. Check the Delta T The Maximum Bo…
Details
10152
cant write EXCHANGERTRISELIMIT. The table classifies it as Hold (H).…
Details
10153
cant write DELTAINOUTDELTATENABLE. The table classifies it as Hold (H).…
Details
10154
cant writ DISABLECHANTICONDENSATION. The table classifies it as Hold (H).…
Details
10155
cant write DISABLEDHWSTORAGE. exceeded. 1. Check settings for operation causing high temperatures. 2. Check boiler pump for proper operation…
Details
10156
cant wrt DISABLEDHWFROSTPROTECTION. The table classifies it as Hold (H).…
Details
10157
cant write DISABLECHFROSTPROTECTION. The table classifies it as Hold (H).…
Details
10158
cant DISABLELEADLAGFROSTPROTECTION. The table classifies it as Hold (H).…
Details
10159
cant write AIRSWITCHLEAFBLOWER. 3. Check Outlet sensor for proper operation. The maximum exhaust temperature is exceeded. 1. Check sensor wi…
Details
10160
cntAIRSWITCHMAXFANSPEEDDIFFERENCE. The table classifies it as Hold (H).…
Details
10161
cannot write AIRSWITCHRATEINCREASE. The table classifies it as Hold (H).…
Details
10162
cant write AIRSWITCHINCREASETIME. possible errors. 2. Check for fouled heat exchanger. The table classifies it as Hold (H).…
Details
10163
cant AIRSWITCHLEAFBLOWERENABLE. The table classifies it as Hold (H).…
Details
10164
cant write LEADLAGSLAVEENABLE. 3. Check for proper combustion 4.check for proper fan speed The table classifies it as Hold (H).…
Details
10165
cannot write LEADLAGMASTER. The table classifies it as Hold (H).…
Details
10166
cant write LEADLAGOPERATIONSWITCH. 5.Check for proper boiler settings 6. Replace the Stack high limit. The table classifies it as Hold (H).…
Details
10167
cannot write RUN_FANONLYRATE. The table classifies it as Hold (H).…
Details
10168
cannot write LEADLAGMODBUSPORT. 7. If previous steps are correct and fault persists, replace the Sola module. The table classifies it as Hol…
Details
10169
cannot write HXHIGHLIMITENABLE. The table classifies it as Hold (H).…
Details
10170
cannot write HXHIGHLIMITSETPOINT. The table classifies it as Hold (H).…
Details
10171
cannot write HXHIGHLIMITRESPONSE. The communication between the Nuro and the Sola has been lost. 1. Check the wiring connections between the…
Details
10172
cannot write HXHIGHLIMITDELAY. The table classifies it as Hold (H).…
Details
10173
cannot write HXHIGHLIMITRETRYLIMIT. The table classifies it as Hold (H).…
Details
10174
cannot write DBISPARKTIME. The table classifies it as Hold (H).…
Lockout
10175
cannot write FLOWSWITCHENABLE. The table classifies it as Hold (H).…
Details
10176
cant write FLOWSWITCHDEBOUNCETIME. terminals. 2. Check for interference sources. 3. Check for proper grounding The inlet sensor temperature …
Details
10177
cannot write DAMPERPROVING. The table classifies it as Hold (H).…
Details
10178
cant DAMPERPROVINGDEBOUNCETIME. The table classifies it as Hold (H).…
Details
10179
cannot write INLET. The table classifies it as Hold (H).…
Details
10180
cannot write ANALOGIN. The table classifies it as Hold (H).…
Details
10181
cannot write OUTLET. 1. Check for proper system piping. 2. Check pumping system for proper flow. The Control program was started at this tim…
Details
10182
cannot write ODAHEAD. The table classifies it as Hold (H).…
Details
10183
cannot write DHW. The table classifies it as Hold (H).…
Details
10184
cannot write STACK. The table classifies it as Hold (H).…
Details
10185
cant write MODBUSHEARTBEATTIMEOUT. Settings is set to an invalid selection. Please Change this value to Setpoint or None. The table classifi…
Details
10186
cant write MODBUSHSICONTROL. The table classifies it as Hold (H).…
Details
10187
cannot write ODATEMPSOURCE. The table classifies it as Hold (H).…
Details
10188
cant write WARMWEATHERSHUTDOWN. The table classifies it as Hold (H).…
Details
10189
cant write USESTATENVIRREMOTE. The table classifies it as Hold (H).…
Details
10190
cannot write LINEFREQUENCY. The table classifies it as Hold (H).…
Details
10191
cant writ MODBUSANALOGOUTCONTROL. The table classifies it as Hold (H).…
Details
10192
cannot write AIRSWITCHRATEDECREASE. The table classifies it as Hold (H).…
Details
10193
cannot write AIRSWITCHDECREASETIME. The table classifies it as Hold (H).…
Details
10194
cannot write LEADLAGDHWDEMAND. Priority will occur. The table classifies it as Hold (H).…
Details
10195
cannot write OFFAUX2PUMP. The table classifies it as Hold (H).…
Details
10196
cannot write BURNERNAME. Check the Cascade Master Enable and the Cascade ODA/Aux1 Priority Change parameter. Only one of these parameters Th…
Details
10197
cannot write INSTALLATIONDATA. The table classifies it as Hold (H).…
Details
10198
cannot write OEMID. The table classifies it as Hold (H).…
Details
10199
cannot write Unknown Parameter. should be set to Aux1 The ODA sensor is Out of Range. The member boiler start sequence will not be The table…
Details
10200
User Changed the SOLA Alert Handler. The table classifies it as Lockout (L).…
Lockout
10201
cannot write Stepped. reversed. Check the ODA sensor and wires. Check the Cascade ODA/Aux1 Priority Change parameter. Ensure this parameter …
Details
10202
cannot write Stepped. The table classifies it as Hold (H).…
Details
10203
Delta T Limit has been reached. The Cascade Member Lost Communication with the Master Check the Cascade wires between the Master and the Mem…
Details
10204
Maximum Outlet Temperature reached. not be used on the Master Check the Cascade Master Enable and the Cascade ODA/Aux1 Priority Change param…
Details
10205
Maximum Stack Temperature reached. The Cascade Master is setup to use a bypass valve. No boiler in the cascade system has a bypass valve sel…
Details
10206
Control Communication Lost. Valve parameter to NO The cascade Master is set to valve control. You must select a relay output to control a bo…
Details
10207
Inlet / Outlet Reversed. The system has now opened a boiler valve to maintain flow through the system. Please verify the bypass valves opera…
Details
10208
Control Started. The table classifies it as Hold (H).…
Details
10209
Invalid Cascade CH Mode. the Nuro and Sola. 1. Check the wiring connections between the Modbus terminals and the Sola MB1 terminals. 2. Chec…
Details
10210
Aux 1 Used for multiple functions. pairing operation 2. If you replaced both the Nuro and the Sola perform a boiler type selection operation…
Details
10211
ODA sensor in Priority Change. The control is unable to write the SAFTEY CONFIGURATION OPTIONS variable to the SOLA 1. Power the module off …
Details
10212
Member Lost Comm with Master. The BMS Header Temperature has not been sent or the BMS Heartbeat has not been updated in the BMS Heartbeat Ti…
Details
10213
Aux 1 selected for multiple functions. The BMS Header Temperature is out-of-range The valid temperatures are between -40 degrees and 130 deg…
Details
10214
No relay is assigned for a bypass valve. 2. If the boiler is not getting the Outdoor Air Temperature from the BMS System, then change the Ou…
Details
10215
No relay is assigned for valve control. 1. Check to make sure the Wireless Outdoor Air Sensor is paired with the controller 2. Check to make…
Details
10216
Bypass Valve failed to Open. source, then change the Outdoor Air Temperature Source The Wireless Outdoor Air Temperature is not reporting a …
Details
10217
NURO / SOLA Communication Issue. The BMS Analog Input has not been sent or the BMS Heartbeat has not been updated in the BMS Heartbeat Timeo…
Details
10218
NURO / SOLA are not Paired. The BMS Analog Input is out-of-range The valid range are numbers between 40 and 200 which relates to .1mA preces…
Details
10219
cannot write Safety Configuration. if not change the BMS Heartbeat parameter The DHW Temperature Source is Invalid for the DHW Control Metho…
Details
10220
Waiting for BMS Header Temperature. 2. This error is from the DHW Temperature Source being set to BMS DHW Temperature when in DHW Control Me…
Details
10221
BMS Header Temperature out-of-range. the BMS Heartbeat Timeout Period 1. Check to make sure the Boiler is still communicating to the BMS Sys…
Details
10222
Waiting for Outdoor Air Temperature. change the DHW Temperature Source The BMS DHW Temperature is out-of-range The valid temperatures are be…
Details
10223
BMS Outdoor Air Temperature out-of range. boiler can operate. If this is a new NURO controller please follow the procedure to select boiler …
Details
10224
Waiting for Wireless Outdoor Air Temperature. 2. Check the communication between the NURO and the SOLA 3. Contact the factory for a replacem…
Details
10225
Wireless Outdoor Air Temperature out-of- range. The high gas limit switch has tripped or the Dual Fuel Circuit has detected a problem 1. Che…
Details
10226
Waiting for BMS Analog Input Value. open simultaneously when the boiler attempts to start. 7. Verify only one Current Switch relay is active…
Details
10227
BMS Analog Input out-of-range. The table classifies it as Hold (H).…
Details
10228
BMS Heartbeat Lost. 2. Check for blocked condensate drain. 3. Check for a blocked heat exchanger. 4. Check for a blocked/ dirty burner. 5. C…
Details
10229
DHW Temperature Source Invalid. The primary selected Header Sensor failed. Check the sensor. 1. Check wiring and correct any possible errors…
Details
10230
Waiting for BMS DHW Temperature. d. Check for proper boiler settings. 3. Replace the Stack sensor or Stack Limit Switch. 4. If previous step…
Details
10231
BMS DHW Temperature out-of-range. temperature on the burner door or rear heat exchanger. 1. Determine which switch is tripped. If either The…
Details
10232
The Boiler Type is unknown. switch is tripped: contact Patterson-Kelley factory support. 2. If neither switch is tripped, check the wiring a…
Details
10233
Unknown SOLA Version. persists, replace the module. The external low water level device has tripped indicating insufficient water level in t…
Details
10234
Unknown SOLA Password. used) or the terminal strip jumper. 2. Check boiler pump for proper operation. 3. Check the external low water level …
Details
10235
High Gas Limit / Dual Fuel Relays. The table classifies it as Hold/Lockout (H/L).…
Lockout
10236
High Back Pressure in Stack or Burner Hood. The table classifies it as Hold (H).…
Details
10237
The Primary Header Sensor failed and an Alternate is being used. The table classifies it as Hold (H).…
Details
10238
Stack sensor fault. The table classifies it as Hold (H).…
Details
10239
HX Sensor Fault. The table classifies it as Hold (H).…
Details
10240
Low Water Limit. The table classifies it as Hold/Lockout (H/L).…
Lockout
10241
Flow Switch lost during Run. The flow switch opened when it should have been closed. 1. Check the pump 2. Check for flow obstructions The ta…
Details
10242
Fan Speed Light Off Recycle. The Fan Speed was not steady during ignition. 1. Check fan wiring and correct any potential wiring errors. 2. C…
Lockout