Patterson-Kelley · Error codes
Patterson-Kelley 193 — Invalid Ignite Failure Delay Setting
193
Invalid ignite failure delay setting. proper software. The table classifies it as Lockout (L).
If you smell gas
- Stop what you are doing. Do not use phones, switches, matches or anything that can spark inside.
- Go outside and leave the door open behind you.
- Call the FortisBC 24-hour emergency line at 1-800-663-9911 or dial 911.
Only after that, call ROMA about the boiler. Official guidance: FortisBC gas leaks and odour.
Applies to
This ignition fault code is displayed by the NURO touchscreen control with Sola burner control on MODU-FIRE FD (N750–N3000) and THERMIFIC VELOX (N750–N2000) appliances equipped with the NURO touchscreen control, as documented in NURO Advanced User's Guide, doc 1004905979 Rev G (March 2016), Appendix C Error Reference Table (1004905979 Rev G). Codes can differ between controller generations, so always check the manual that matches your unit.
- Patterson-Kelley P-K MODU-FIRE FD
- Patterson-Kelley P-K THERMIFIC VELOX
- P-K MODU-FIRE FD N750
- P-K MODU-FIRE FD N1000
- P-K MODU-FIRE FD N1500
- P-K MODU-FIRE FD N2000
- P-K MODU-FIRE FD N2500
- P-K MODU-FIRE FD N3000
- P-K THERMIFIC VELOX N750
- P-K THERMIFIC VELOX N1000
- P-K THERMIFIC VELOX N1500
- P-K THERMIFIC VELOX N1700
- P-K THERMIFIC VELOX N2000
Controller: NURO touchscreen control with Sola burner control. Source manual: 1004905979 Rev G (2016-03).
Why a code is not a diagnosis
An ignition code says the burner did not prove a flame when it should have; it does not say why. Gas supply, ignition components, grounding, venting and the control module each need testing on site.
Safe things to observe
- If you smell gas, stop, go outside and call your gas utility's emergency line or 911 before anything else.
- Note the exact code and what the appliance was doing when it appeared.
- Check whether other gas appliances in the building are working.
Do not
- Do not keep resetting to force more ignition attempts.
- Do not open the gas valve, touch ignition components or bypass any safety device.
How professional service helps
- A licensed gas technician tests gas supply pressure and the shut-off state.
- The ignition probe, lead, gap and grounding are inspected against the manufacturer's specification.
- Combustion and safety devices are verified with an analyser and the manufacturer's procedure after any repair.
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Frequently asked questions
Does this code mean I have a gas leak?
Not by itself. If you smell gas, stop, leave the building and call your gas utility's emergency line or 911 from outside before anything else. Otherwise the code points to a fault a technician confirms on site.
Can I clear this code myself?
Clearing a code without fixing its cause usually just brings it back. Note the code, check the safe items on this page, then call a licensed technician. If your appliance manual describes a user reset for this exact code and it stays away, no call may be needed.
Boiler locked out? Call with the alert text ready.
The brand, model and this alert are passed along when you request service online, so the technician arrives prepared.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- NURO Advanced User's Guide, doc 1004905979 Rev G (March 2016), Appendix C Error Reference Table · 1004905979 Rev G · accessed September 9, 2026
Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.