Skip to content
Boilers.caby ROMA Heating & Cooling

Pennco · 16 Series

Pennco 1609HSID

The Pennco 1609HSID is the largest 16 Series size: 299/280 MBH input (natural gas/LP) with 245/229 MBH heating capacity and a 184/172 MBH net steam rating at 82% AFUE.

CurrentCanadian status unknown

Key figures

Max input
299 / 280 MBH
Max CSA output
AFUE
82 %
Min input
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Pennco 1609HSID in practice

The Pennco 1609HSID is a cast-iron gas-fired steam boiler rated at 299/280 MBH input on natural gas/LP. Its row in the 16 Series sell sheet prints 245/229 MBH heating capacity, a 184/172 MBH AHRI net steam rating at a 1.333 piping and pickup allowance, 766/717 steam square feet and 82% AFUE, with a 7" flue, a 30-3/4"-wide cabinet and an approximate weight of 736 lb.

The boiler ships fully assembled with an insulated jacket and a completely installed and wired gas control system: titanium composite burners, a gas manifold with orifices, an automatic redundant combination gas valve, intermittent pilot control with continuous retry and 100% shut-off, a combination pilot burner/electrode/flame sensor and an integral draft diverter. Standard equipment also includes an electronic low-water cut-off with 3/4-inch probe, pressure limit control, steam pressure gauge, glass water level gauge, blocked vent spill switch, flame roll-out fuse link and a 15 psi ASME pop safety valve. Ratings are for sea level to 2,000 feet with a four percent reduction per 1,000 feet above that.

Boilers.ca documents this size at model level from the sell sheet and links the published IOM and near-boiler piping guide. Steam, gas and venting work belongs with a licensed contractor. No official Canadian-sales statement was found, so canadianStatus stays 'unknown'.

Best suited to

  • 299 MBH residential steam loads (natural gas)
  • Systems needing about 766 square feet of steam radiation
  • Homes with an existing chimney and a 5- to 7-inch flue

Applicability and support

Model number
1609HSID
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Pennco. Units are shown with every value; notes flag conflicting sources or missing figures.

Pennco 1609HSID specifications
SpecificationValueNote
Input
Input (natural gas / LP)299 / 280 MBHAHRI certified input printed as a natural-gas/LP pair per the 16 Series sell sheet (sea level to 2,000 ft; reduce 4% per 1,000 ft above that).
Output
Heating capacity (natural gas / LP)245 / 229 MBHHeating capacity printed as a natural-gas/LP pair per the 16 Series sell sheet.
Net steam (natural gas / LP)184 / 172 MBHAHRI net steam rating printed as a natural-gas/LP pair, based on a piping and pickup allowance of 1.333.
Steam square feet (natural gas / LP)766 / 717 sq ftSteam square feet printed as a natural-gas/LP pair per the 16 Series sell sheet.
Efficiency
Efficiency (AFUE)82 %AFUE per the 16 Series sell sheet ratings table (1603HSID 82.7%, 1604HSID through 1609HSID 82.0%).
Domestic hot water
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Venting and air
Flue diameter7"Flue diameter per the 16 Series sell sheet; an integral draft diverter is standard.
VentingChimney vented with integral draft diverterBlocked vent safety shut-off (spill switch) and flame roll-out fuse link are standard.
Physical and connections
Approx. shipping weight736 lbApproximate weight per the 16 Series sell sheet ratings table.
Dimensions (width × height × depth)30-3/4" × 36-3/8" × 26-1/2"16 Series dimension values; height and depth are common across the line.
Steam connections2" supply and 2" returnSteam connection sizes per the 16 Series IOM and near-boiler piping guide.
Operating limits and other
ControlIntermittent pilot control with continuous retry and 100% shut-offStandard equipment includes electronic low-water cut-off with 3/4" probe, pressure limit control, steam pressure gauge and glass water level gauge.
FuelNatural gas or propane (conversion kits available)Ratings are printed as natural-gas/LP pairs and natural-gas-to-propane conversion kits are listed among the options.

Frequently asked questions

What are the Pennco 1609HSID's ratings?

299/280 MBH input (natural gas/LP), 245/229 MBH heating capacity, a 184/172 MBH net steam rating (766/717 sq ft) and 82% AFUE with a 7" flue per the 16 Series sell sheet.

Can the 1609HSID be converted to propane?

Yes — the ratings are printed as natural-gas/LP pairs and the sell sheet lists natural-gas-to-propane conversion kits among the options.

Questions about the Pennco 1609HSID?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate