Skip to content
Boilers.caby ROMA Heating & Cooling

Raypak · Series

Raypak XTherm

The XTherm is Raypak's vertical modulating condensing boiler with 'high-recovery copper fin technology', in model sizes H7-1005A through H7-4005A (1005–4005 MBH class), with public English and French I&O manuals split across the 1005A–2005A and 2505–4005 size groups.

Current seriesunknownNatural gascommercial

Series facts

Type
condensing
Efficiency
Unknown
Fuel
Natural gas per the captured page; propane configuration is not reprinted on the captured text.
Venting
Unknown
Models documented
6
Warranty
Not verified

About the XTherm

Raypak describes the XTherm as a 'vertical modulating condensing boiler … high-recovery copper fin technology' — a condensing copper-fin vertical design. The product-page documentation rows list model sizes H7-1005A, H7-1505A, H7-2005A, H7-3005, H7-3505 and H7-4005, i.e. the 1005A–4005 family.

Efficiency percentages for the XTherm are published in the spec sheets rather than the captured page text, so no structured percentage is printed here.

Raypak splits the public I&O manuals by size range: 241513 (with a French edition) for the 1005A–2005A models and 241549 (with a French edition) for the 2505–4005 models.

Highlights

  • Vertical modulating condensing boiler with high-recovery copper fin technology
  • Models H7-1005A / 1505A / 2005A / 3005 / 3505 / 4005 (1005A–4005 family)
  • I&O manuals 241513 (1005A–2005A) and 241549 (2505–4005), EN + FR

Models

XTherm models

One canonical page per model with input, output and efficiency kept separate.

CurrentCanadian status unknown
Input
—
Output (max)
959 MBH
AFUE
—

The Raypak XTherm H7-1005A is a vertical modulating condensing commercial hydronic boiler rated 999 MBTUH input and 959 MBTUH output at 96% thermal efficiency, with 7:1 turndown, Category IV venting and a 6 in flue.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
1,440 MBH
AFUE
—

The Raypak XTherm H7-1505A is a vertical modulating condensing commercial hydronic boiler rated 1,500 MBTUH input and 1,440 MBTUH output at 96% thermal efficiency, with 7:1 turndown, Category IV venting and a 8 in flue.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
1,919 MBH
AFUE
—

The Raypak XTherm H7-2005A is a vertical modulating condensing commercial hydronic boiler rated 1,999 MBTUH input and 1,919 MBTUH output at 96% thermal efficiency, with 7:1 turndown, Category IV venting and a 8 in flue.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
2,880 MBH
AFUE
—

The Raypak XTherm H7-3005 is a vertical modulating condensing commercial hydronic boiler rated 3,000 MBTUH input and 2,880 MBTUH output at 96% thermal efficiency, with 10:1 turndown, Category IV venting and a 10 in flue.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
3,360 MBH
AFUE
—

The Raypak XTherm H7-3505 is a vertical modulating condensing commercial hydronic boiler rated 3,500 MBTUH input and 3,360 MBTUH output at 96% thermal efficiency, with 10:1 turndown, Category IV venting and a 10 in flue.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
3,840 MBH
AFUE
—

The Raypak XTherm H7-4005 is a vertical modulating condensing commercial hydronic boiler rated 4,000 MBTUH input and 3,840 MBTUH output at 96% thermal efficiency, with 7:1 turndown, Category IV venting and a 12 in flue.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Raypak XTherm H7-1005A and Raypak XTherm H7-1505A and Raypak XTherm H7-2005A and Raypak XTherm H7-3005 and Raypak XTherm H7-3505 and Raypak XTherm H7-4005
SpecificationRaypak XTherm H7-1005ARaypak XTherm H7-1505ARaypak XTherm H7-2005ARaypak XTherm H7-3005Raypak XTherm H7-3505Raypak XTherm H7-4005
input-min——————
Input999 MBH1,500 MBH1,999 MBH3,000 MBH3,500 MBH4,000 MBH
Output959 MBH1,440 MBH1,919 MBH2,880 MBH3,360 MBH3,840 MBH
afue——————
Turndown7:17:17:110:110:17:1
vent-max-3——————
vent-max-2——————
Weight1,065 lb1,234 lb1,461 lb2,775 lb2,925 lb3,058 lb

Read the full comparison: Raypak XTherm H7-1005A vs XTherm H7-1505A →

Read the full comparison: Raypak XTherm H7-1505A vs XTherm H7-2005A →

Read the full comparison: Raypak XTherm H7-2005A vs XTherm H7-3005 →

Read the full comparison: Raypak XTherm H7-3505 vs XTherm H7-4005 →

Error codes and alerts

XTherm alerts

  • OUTLET SENVERSA IC control with PIM (error items shown on the touchscreen display)
  • LIMIT SENVERSA IC control with PIM (error items shown on the touchscreen display)
  • INLET SENVERSA IC control with PIM (error items shown on the touchscreen display)
  • GAS PRESSVERSA IC control with PIM (error items shown on the touchscreen display)
  • IGNITIONVERSA IC control with PIM (error items shown on the touchscreen display)
  • LIMIT TRIPVERSA IC control with PIM (error items shown on the touchscreen display)
  • FLAMEVERSA IC control with PIM (error items shown on the touchscreen display)
  • ID CARDVERSA IC control with PIM (error items shown on the touchscreen display)
  • IGN CTRLVERSA IC control with PIM (error items shown on the touchscreen display)
  • DELTA TVERSA IC control with PIM (error items shown on the touchscreen display)
  • LOW 24VACVERSA IC control with PIM (error items shown on the touchscreen display)
  • BLOW SPEEDVERSA IC control with PIM (error items shown on the touchscreen display)
  • FLOW ERRORVERSA IC control with PIM (error items shown on the touchscreen display)
  • UNDER FLOWVERSA IC control with PIM (error items shown on the touchscreen display)
  • FLOW WARNINGVERSA IC control with PIM (error items shown on the touchscreen display)
  • OUTLET SENVERSA IC control with PIM (error items shown on the touchscreen display)
  • LIMIT SENVERSA IC control with PIM (error items shown on the touchscreen display)
  • INLET SENVERSA IC control with PIM (error items shown on the touchscreen display)
  • GAS PRESSVERSA IC control with PIM (error items shown on the touchscreen display)
  • IGNITIONVERSA IC control with PIM (error items shown on the touchscreen display)
  • LIMIT TRIPVERSA IC control with PIM (error items shown on the touchscreen display)
  • FLAMEVERSA IC control with PIM (error items shown on the touchscreen display)
  • ID CARDVERSA IC control with PIM (error items shown on the touchscreen display)
  • IGN CTRLVERSA IC control with PIM (error items shown on the touchscreen display)
  • DELTA TVERSA IC control with PIM (error items shown on the touchscreen display)
  • LOW 24VACVERSA IC control with PIM (error items shown on the touchscreen display)
  • BLOW SPEEDVERSA IC control with PIM (error items shown on the touchscreen display)

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

Is the XTherm condensing?

Yes. Raypak lists XTherm under its condensing hydronic boilers and describes it as a vertical modulating condensing boiler with high-recovery copper fin technology.

Which XTherm manuals apply to which sizes?

Raypak publishes I&O 241513 (EN/FR) for the 1005A–2005A sizes and I&O 241549 (EN/FR) for the 2505–4005 sizes.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.