Rinnai · Error codes

Rinnai i-Series (previous generation) 999 — Pc Board Mismatch

999

LockoutRinnai previous-generation I-Series solo boilers (diagnostic codes, manual 800000112 hosted on the i060SN product page)

PC Board Mismatch. • This code occurs when the PC Board and the internal logic do not match. • Check if the software versions of the board and operation board do not match. FFF Maintenance Indicator • This code is a placeholder in diagnostic code history indicating a service provider performed maintenance or service. • Enter this code after performing service by pressing and holding the Up button, then press and hold the Down button, and then press the Indirect Tank button simultaneously. FFF will appear on the display. E;FFF Up and Down Press the Indirect Tank button No Code Boiler does not start heating with a heating demand present • Supply temperature or return temperature inside the boiler may be too hot. • Ensure the pump operates properly. No Code Boiler does not start heating the indirect tank, although the indirect tank is calling for heat • After the tank priority time (Parameter 34) passes, the boiler will be in heating priority for 60 minutes. No Code The boiler does not operate with the CH setting button • If DIP switch 2 is OFF, CH operation will operate via the room thermostat. No Code Supply temperature is different from the setting temperature on the controller • During outdoor sensor control, the supply temperature will vary dependent on the outdoor temperature. • During simultaneous operation of an Indirect Tank and CH, the supply temperature for CH is based on Indirect Tank control. No Code CH capacity is insufficient • Ensure the parameters are properly set for the installation. • During simultaneous operation of an Indirect Tank and CH, flow volume to heating can be reduced. No Code Pump or fan even with no demand • The boiler may start or operate the pump for freeze protection operation. • The pump may intermittently operate to prevent it from becoming stuck. 13 Topics in this section • Owner Maintenance • Licensed Professional Maintenance • Test the Ignition Safety Shut Off Device WARNING If you encounter a problem that is difficult to solve, stop the operation and immediately contact a licensed professional. MONTHLY Boiler Area • Verify the area is free of combustible materials, gasoline and other flammable vapors and liquids. • Verify the area is clean from dust and obstructions • Verify the air intake area is free of any contaminants listed in the boiler Installation and Operation Manual. Any contaminants in the boiler intake air vicinity must be removed. If they cannot be removed, contact a licensed professional. Piping • Inspect all water, gas, and condensation piping for leaks. Look for signs of leaking lines or corrosion. • Confirm the condensation line is not blocked. If a condensation drain pump is used, confirm the condensation drain pump operates correctly. Venting • Verify the boiler vent discharge and air intake is clean and free of obstructions. • Check for leakage, damage, or deformation of venting. Boiler • Verify the boiler is free from any abnormal situations, such as diagnostic error codes, loud noises, leakage or other potential issues. • Check that the pressure on the controller display or external pressure gauge indicates 17-26 psi (117-180 kPa). The table classifies it as Diagnostic Code.

Applies to

This ignition fault code is displayed by the I-Series control (numeric diagnostic codes) on Previous-generation I-Series solo models (i060SN, i090SN, i120SN, i150SN), as documented in Rinnai I-Series Condensing Solo Boiler Installation and Operation Manual, doc 800000112 (hosted on the Rinnai Canada i060SN product page), Section 12.8 Diagnostic Codes (800000112). Codes can differ between controller generations, so always check the manual that matches your unit.

Controller: I-Series control (numeric diagnostic codes). Source manual: 800000112.

Why a code is not a diagnosis

An ignition code says the burner did not prove a flame when it should have; it does not say why. Gas supply, ignition components, grounding, venting and the control module each need testing on site.

Safe things to observe

  • If you smell gas, stop, go outside and call your gas utility's emergency line or 911 before anything else.
  • Note the exact code and what the appliance was doing when it appeared.
  • Check whether other gas appliances in the building are working.

Do not

  • Do not keep resetting to force more ignition attempts.
  • Do not open the gas valve, touch ignition components or bypass any safety device.

How professional service helps

  1. A licensed gas technician tests gas supply pressure and the shut-off state.
  2. The ignition probe, lead, gap and grounding are inspected against the manufacturer's specification.
  3. Combustion and safety devices are verified with an analyser and the manufacturer's procedure after any repair.

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Parts and service

Parts commonly involved

These parts appear in the documented text for this alert. A code reports a condition, not a failed part — a technician confirms the cause by testing before anything is replaced.

Service for this alert

  • Gas Boiler Repair

    Licensed gas technicians from ROMA Heating & Cooling diagnose and repair residential and light-commercial gas boilers across…

  • Emergency Boiler Repair

    Priority gas boiler repair for homes and buildings in Greater Vancouver with no heat, no hot water, a locked-out boiler or a leak.

Every boiler part explained — what it does, how it fails and what a technician checks.

Documented for Rinnai i-Series (previous generation).

Frequently asked questions

Does this code mean I have a gas leak?

Not by itself. If you smell gas, stop, leave the building and call your gas utility's emergency line or 911 from outside before anything else. Otherwise the code points to a fault a technician confirms on site.

Can I clear this code myself?

Clearing a code without fixing its cause usually just brings it back. Note the code, check the safe items on this page, then call a licensed technician. If your appliance manual describes a user reset for this exact code and it stays away, no call may be needed.

Boiler locked out? Call with the alert text ready.

The brand, model and this alert are passed along when you request service online, so the technician arrives prepared.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate