Skip to content
Boilers.caby ROMA Heating & Cooling

Rinnai · Series

Rinnai Q-Series

The Q-Series was Rinnai's large residential and light-commercial condensing boiler line — the Q175CN combi plus the Q85SN, Q130SN, Q175SN and Q205SN heating-only models. Its rinnai.ca pages remain live and unlinked, and Boilers.ca documents each model from the spec rows printed on its own page.

discontinuedhistoricalNatural gasresidential

Series facts

Type
condensing
Efficiency
Unknown
Fuel
Every Q-series product page prints a Gas Type row of Natural Gas; no propane row appears on the captured pages, so propane is not recorded for this line.
Venting
Unknown
Models documented
5
Warranty
Not verified

About the Q-Series

The Q-Series covered Rinnai's larger residential condensing boilers: the Q175CN combination model, which produces heat and domestic hot water, and four heating-only models, Q85SN, Q130SN, Q175SN and Q205SN, with central-heating capacities of 85,000, 130,000, 175,000 and 205,000 BTU/h. The pages describe the line as ideal for homes or light commercial applications, and each page prints its own minimum/maximum input bullets, weight, dimensions, gas connection and — on the combi — the maximum domestic hot water flow rate.

The Q pages are live on rinnai.ca but are not linked from the current condensing-boilers navigation, which lists only the IP-coded I-SERIES+ line, and there is no Q-series category page; Boilers.ca therefore records the line as a legacy generation with official pages remaining, the same treatment given to the older i- and M-Series. Page-print quirks are kept and flagged: the solo pages' maximum-input bullets print the truncated value "N (maximum)", and the Q175CN's unlabelled 175,000 BTU maximum bullet matches its printed central-heating capacity rather than a separate DHW figure.

The Q pages are natural-gas models and print Residential ENERGY STAR and SCAQMD Ultra Low NOx rows. No AFUE percentage, turndown, venting length or water-content figure is printed on the orphaned pages, so none is recorded here. Owners should match manuals, parts and service literature to the model code on the rating plate rather than to current I-SERIES+ documents.

Highlights

  • Q175CN combi plus Q85SN, Q130SN, Q175SN and Q205SN heating-only models
  • Central-heating capacities 85,000 / 130,000 / 175,000 / 205,000 BTU/h
  • Official rinnai.ca pages live but unlinked; no Q-series category page
  • Natural-gas pages with ENERGY STAR and SCAQMD Ultra Low NOx rows
  • Solo pages print the truncated "N (maximum)" bullet — kept as printed

Models

Q-Series models

One canonical page per model with input, output and efficiency kept separate.

DiscontinuedHistorically in Canada
Input
17–N (maximum) — page print bug undefined
Output (max)
AFUE

The Rinnai Q85SN is a heating-only model in the Q-Series: a condensing boiler with a 85,000 BTU central-heating capacity and no domestic hot water production, at 110 lb.

Natural gasHeating-only
DiscontinuedHistorically in Canada
Input
26–N (maximum) — page print bug undefined
Output (max)
AFUE

The Rinnai Q130SN is a heating-only model in the Q-Series: a condensing boiler with a 130,000 BTU central-heating capacity and no domestic hot water production, at 117 lb.

Natural gasHeating-only
DiscontinuedHistorically in Canada
Input
35–175 MBH
Output (max)
AFUE

The Rinnai Q175CN is the combination model in the Q-Series: a condensing boiler with a 175,000 BTU central-heating capacity and a 6.2 GPM maximum domestic hot water flow, at 196 lb.

Natural gasCombi
DiscontinuedHistorically in Canada
Input
35–N (maximum) — page print bug undefined
Output (max)
AFUE

The Rinnai Q175SN is a heating-only model in the Q-Series: a condensing boiler with a 175,000 BTU central-heating capacity and no domestic hot water production, at 141 lb.

Natural gasHeating-only
DiscontinuedHistorically in Canada
Input
41–N (maximum) — page print bug undefined
Output (max)
AFUE

The Rinnai Q205SN is a heating-only model in the Q-Series: a condensing boiler with a 205,000 BTU central-heating capacity and no domestic hot water production, at 141 lb.

Natural gasHeating-only

Compare models in this series

Comparison of Rinnai Q85SN and Rinnai Q130SN and Rinnai Q175CN and Rinnai Q175SN and Rinnai Q205SN
SpecificationRinnai Q85SNRinnai Q130SNRinnai Q175CNRinnai Q175SNRinnai Q205SN
Minimum input (hero bullet)17 MBH26 MBH35 MBH35 MBH41 MBH
Maximum input (hero bullet, as printed)N (maximum) — page print bugN (maximum) — page print bug175 MBHN (maximum) — page print bugN (maximum) — page print bug
output-max
afue
turndown
vent-max-3
vent-max-2
Product weight110 lb117 lb196 lb141 lb141 lb

Read the full comparison: Rinnai Q85SN vs Q130SN

Read the full comparison: Rinnai Q175CN vs Q175SN

Read the full comparison: Rinnai Q175SN vs Q205SN

Read the full comparison: Rinnai Q175CN vs Rinnai Q130SN

Error codes and alerts

Q-Series alerts

  • Block 01Q-Series control (block and error display)
  • Block 05Q-Series control (block and error display)
  • Block 60Q-Series control (block and error display)
  • Block 67Q-Series control (block and error display)
  • Block 85Q-Series control (block and error display)
  • Error 00Q-Series control (block and error display)
  • Error 02Q-Series control (block and error display)
  • Error 04Q-Series control (block and error display)
  • Error 05Q-Series control (block and error display)
  • Error 12Q-Series control (block and error display)
  • Error 18Q-Series control (block and error display)
  • Error 19Q-Series control (block and error display)
  • Error 28Q-Series control (block and error display)
  • Error 69Q-Series control (block and error display)

Manuals

Official documents

    Where ROMA provides on-site service

    On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

    See all service areas

    Frequently asked questions

    Which models make up Rinnai's Q-Series?

    Five official product pages are live on rinnai.ca: the Q175CN combination boiler and the Q85SN, Q130SN, Q175SN and Q205SN heating-only boilers, with central-heating capacities of 85,000, 130,000, 175,000 and 205,000 BTU/h for the solos and a 175,000 BTU/h capacity on the combi.

    Is the Q-Series still sold?

    The Q pages are live but are not linked from rinnai.ca's current condensing-boilers navigation, which lists only the I-SERIES+ line, and no Q-series category page exists. Boilers.ca records the line as a legacy generation with official pages remaining; confirm current availability with Rinnai before specifying.

    Does the Q175CN make domestic hot water?

    Yes. The Q175CN is the combination model in the Q-Series: its page prints a 6.2 GPM maximum domestic hot water flow rate plus 3/4" cold-inlet and hot-outlet connections. The four SN models are heating-only.

    Talk to a boiler technician

    Describe what the boiler is doing and get a straight answer about the next step.

    On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

    Sources and verification

    Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

    CallEmailEstimate