The Takagi T-D2 Series is a line of non-condensing tankless water heaters — not boilers — in indoor (IN) and outdoor (OS) versions at 199,000 BTU/h input, documented by Takagi for domestic hot water and combined domestic & heating applications.

Current seriesunknownNatural gasPropaneresidential

Series facts

Type
dhw-only
Efficiency
Unknown
Fuel
The official specification sheet prints separate natural-gas (-N) and propane (-P) models; no field conversion kit is printed for the T-D2 in the captured literature.
Venting
Indoor models use 4" Category III venting to 50 equivalent ft (5 elbows max, 90° elbows = 5 ft equivalent) and can be direct-vented with an optional conversion kit and 3" intake; outdoor models have an integral exhaust vent. Per the official specification sheet TRGSS01613.
Models documented
4
Warranty
Not verified

About the T-D2 Series

The T-D2 Series is a non-condensing tankless water heater family: T-D2-IN-N and T-D2-IN-P (indoor) and T-D2-OS-N and T-D2-OS-P (outdoor), each firing 11,000 to 199,000 BTU/h with 0.80 thermal efficiency and up to 10.0 GPM per the official specification sheet TRGSS01613. It is a water heater, not a boiler: no Takagi boiler line exists in the captured catalogue.

The specification sheet describes the family as supplying hot water to domestic hot water systems and notes it can be used with water storage tanks, recirculation systems, and/or combined domestic & heating applications. Indoor models carry 4" Category III venting to 50 equivalent ft with an optional direct-vent conversion kit; outdoor models have an integral exhaust vent on the front. Both measure 20-1/4" H × 13-3/4" W × 9-1/2" D, weigh 45 lb, connect on 3/4" NPT water and gas lines, and run on 120 V/60 Hz with a factory-installed power cord on indoor units.

The T-D2 pages are live on takagi.com and the specification sheet prints the full rating table, including a footnote marking the model as suitable for commercial applications. No Canadian availability statement appears on the captured pages, so Canadian availability is recorded as unknown.

Highlights

  • Non-condensing tankless water heaters — DHW-only appliances, not boilers
  • Four models: T-D2-IN-N/P and T-D2-OS-N/P, 11,000–199,000 BTU/h
  • 0.80 thermal efficiency; up to 10.0 GPM maximum flow
  • Indoor models: 4" Category III venting to 50 ft; outdoor models vent directly
  • 45 lb cabinet at 20-1/4 × 13-3/4 × 9-1/2 in; 3/4" NPT water and gas

Models

T-D2 Series models

One canonical page per model with input, output and efficiency kept separate.

CurrentCanadian status unknown
Input
11000–199000 BTU/h
Output (max)
—
AFUE
—

The Takagi T-D2-IN-N is a non-condensing tankless water heater — a DHW-only appliance, not a boiler — firing 11,000 to 199,000 BTU/h on natural gas with 0.8% thermal efficiency and up to 10 GPM.

Natural gasDHW-only (tankless)
CurrentCanadian status unknown
Input
11000–199000 BTU/h
Output (max)
—
AFUE
—

The Takagi T-D2-IN-P is a non-condensing tankless water heater — a DHW-only appliance, not a boiler — firing 11,000 to 199,000 BTU/h on propane with 0.8% thermal efficiency and up to 10 GPM.

PropaneDHW-only (tankless)
CurrentCanadian status unknown
Input
11000–199000 BTU/h
Output (max)
—
AFUE
—

The Takagi T-D2-OS-N is a non-condensing tankless water heater — a DHW-only appliance, not a boiler — firing 11,000 to 199,000 BTU/h on natural gas with 0.8% thermal efficiency and up to 10 GPM.

Natural gasDHW-only (tankless)
CurrentCanadian status unknown
Input
11000–199000 BTU/h
Output (max)
—
AFUE
—

The Takagi T-D2-OS-P is a non-condensing tankless water heater — a DHW-only appliance, not a boiler — firing 11,000 to 199,000 BTU/h on propane with 0.8% thermal efficiency and up to 10 GPM.

PropaneDHW-only (tankless)

Compare models in this series

Comparison of Takagi T-D2-IN-N and Takagi T-D2-IN-P and Takagi T-D2-OS-N and Takagi T-D2-OS-P
SpecificationTakagi T-D2-IN-NTakagi T-D2-IN-PTakagi T-D2-OS-NTakagi T-D2-OS-P
Input, minimum11,000 BTU/h11,000 BTU/h11,000 BTU/h11,000 BTU/h
Input, maximum199,000 BTU/h199,000 BTU/h199,000 BTU/h199,000 BTU/h
output-max————
afue————
turndown————
vent-max-3————
vent-max-2————
Weight45 lb45 lb45 lb45 lb

Read the full comparison: Takagi T-D2-IN-N vs T-D2-OS-N →

Read the full comparison: Takagi T-D2-IN-N vs TK-540P-NIH →

Read the full comparison: Takagi T-D2-IN-N vs Takagi T-D2-IN-P →

Read the full comparison: Takagi T-D2-IN-P vs Takagi T-D2-OS-N →

Read the full comparison: Takagi T-D2-OS-N vs Takagi T-D2-OS-P →

Error codes and alerts

T-D2 Series alerts

  • 031T-D2 control (7-Seg LED and remote controller error codes)
  • 101T-D2 control (7-Seg LED and remote controller error codes)
  • 111T-D2 control (7-Seg LED and remote controller error codes)
  • 121T-D2 control (7-Seg LED and remote controller error codes)
  • 311T-D2 control (7-Seg LED and remote controller error codes)
  • 321T-D2 control (7-Seg LED and remote controller error codes)
  • 331T-D2 control (7-Seg LED and remote controller error codes)
  • 391T-D2 control (7-Seg LED and remote controller error codes)
  • 441T-D2 control (7-Seg LED and remote controller error codes)
  • 510T-D2 control (7-Seg LED and remote controller error codes)
  • 611T-D2 control (7-Seg LED and remote controller error codes)
  • 651T-D2 control (7-Seg LED and remote controller error codes)
  • 701T-D2 control (7-Seg LED and remote controller error codes)
  • 721T-D2 control (7-Seg LED and remote controller error codes)
  • 741T-D2 control (7-Seg LED and remote controller error codes)
  • 761T-D2 control (7-Seg LED and remote controller error codes)
  • 991T-D2 control (7-Seg LED and remote controller error codes)

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

Is the Takagi T-D2 a boiler?

No. The T-D2 is a non-condensing tankless water heater. Takagi's official sheet notes it can be used in combined domestic & heating applications as a water heater; Takagi's catalogue contains no boiler line.

What sizes does the T-D2 Series come in?

One input size — 11,000 to 199,000 BTU/h — in indoor (T-D2-IN) and outdoor (T-D2-OS) versions, each in natural-gas (-N) and propane (-P) models, per specification sheet TRGSS01613.

Can the T-D2 be direct-vented?

The specification sheet states indoor models are vented with 4" Category III pipe to 50 equivalent ft and can be direct-vented with an optional direct-vent conversion kit using a 3" intake pipe. Outdoor models have an integral exhaust vent.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate