U.S. Boiler Company Alpine ALP399C
The U.S. Boiler Company Alpine ALP399C fires 80–399 MBH input with 375 MBH gross output and a 326 MBH net rating at 94.1% thermal efficiency — the largest Alpine size, rated by gross output and thermal efficiency on the data sheet — on the stainless-steel condensing platform with the Sage2.3 touch-screen control.
Key figures
- Max input
- 399 MBH
- Max CSA output
- —
- AFUE
- —
- Min input
- 80 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
U.S. Boiler Company Alpine ALP399C in practice
The Alpine ALP399C is a stainless-steel condensing gas boiler rated at 80–399 MBH input. Its row in the Alpine Product Data Sheet (Form HYDL04081) prints 375 MBH gross output and a 326 MBH net rating at 94.1% thermal efficiency (a thermal-efficiency row rather than an AFUE row). Ratings are for sea level to 2,000 feet and de-rate four percent per additional 1,000 feet.
The boiler ships at approximately 316 lb and measures 31-3/16" wide by 43-1/2" high per the data sheet dimension table. Venting is 4" for exhaust and air intake, and the vent table allows 4" intake/vent to 100 ft per side. Standard equipment includes the Sage2.3 control with LCD touch screen, variable-speed combustion blower, negative-pressure gas valve, stainless-steel heat exchanger, a 30 PSI safety relief valve (50 PSI on the ALP399C) and outdoor reset with a wired outside sensor; the 80–210 sizes are wall or floor mountable and the ALP285B/ALP399C are floor mounted.
Boilers.ca documents this size at model level for identification and service planning. Installation, gas, electrical and venting work belongs with a licensed contractor working from the Alpine I&O manual. No official Canadian-sales statement was found, so canadianStatus stays 'unknown'.
Best suited to
- 80-to-399 MBH residential heat-loss loads
- Light-commercial projects using the Alpine 399 row
- Buyers comparing the six Alpine sizes on the shared Product Data Sheet
Applicability and support
- Model number
- ALP399C
- Canadian availability
- unknown
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by U.S. Boiler Company. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, minimum | 80 MBH | Minimum input per the Alpine Product Data Sheet ratings table (sea level to 2,000 ft). |
| Input, maximum | 399 MBH | Maximum input per the Alpine Product Data Sheet ratings table; ratings de-rate four percent per 1,000 ft above 2,000 ft. |
| Output | ||
| Gross output | 375 MBH | Gross output per the ALP399C row of the Alpine Product Data Sheet — the row is rated with gross output and thermal efficiency rather than DOE heating capacity and AFUE. |
| Net rating | 326 MBH | Net rating per the ALP399C row of the Alpine Product Data Sheet. |
| Efficiency | ||
| Thermal efficiency | 94.1 % | Thermal efficiency printed on the ALP399C row — not an AFUE figure. |
| Domestic hot water | ||
| Domestic hot water | Heating-only boiler — domestic hot water comes from a separate indirect tank or water heater | |
| Venting and air | ||
| Vent and intake size | 4" | Vent and air-intake size per the Product Data Sheet vent table: 4" intake/vent to 100 ft per side. |
| Venting | Direct vent, sealed combustion, Category IV | Direct-vent sealed-combustion appliance with CPVC-to-PVC vent kit included (30" CPVC, 90° elbow, two vent terminals, screens) per the standard equipment list. |
| Physical and connections | ||
| Approx. shipping weight | 316 lb | Approximate shipping weight per the Alpine Product Data Sheet ratings table. |
| Dimensions (width × height) | 31-3/16" × 43-1/2" | Cabinet width and height per the Alpine Product Data Sheet dimension table. |
| Supply/return connections | 1" NPT (3/4" return tapping on ALP080B/ALP105B per the dimension table) | Water connection sizes per the Alpine Product Data Sheet dimension and connection data. |
| Gas connection | 1/2" NPT (3/4" on ALP285B/ALP399C per the dimension table) | Gas valve inlet size per the Alpine Product Data Sheet dimension table. |
| Operating limits and other | ||
| Control | Sage2.3 Boiler Control System with LCD touch screen | Sage2.3 control with self-guided menus, 100+ help screens, built-in self diagnostics, three circulator outputs, eight-boiler sequencer, 4–20 MV inputs, outdoor reset, DHW priority and warm-weather shutdown per the data sheet. |
| Fuel | Natural gas or LP gas | Boilers shipped set for natural gas with field adjustment for LP per the Product Data Sheet notes. |
Manuals
Frequently asked questions
What are the Alpine ALP399C's ratings?
80–399 MBH input, 375 MBH gross output and a 326 MBH net rating at 94.1% thermal efficiency per the Alpine Product Data Sheet.
Can the Alpine ALP399C be wall mounted?
No — the Product Data Sheet lists the 285 and 399 sizes as floor-mounted models; the ALP080B through ALP210B sizes are listed for wall or floor mounting with a pre-installed hanging bracket and wall-mount kit included.
Questions about the U.S. Boiler Company Alpine ALP399C?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- U.S. Boiler Company — Alpine High Efficiency Condensing Gas Boiler product page · accessed September 9, 2026
- Alpine Product Data Sheet, Form HYDL04081 (PDF) · HYDL04081 · accessed September 9, 2026
- Alpine Installation, Operating and Service Instructions (PDF) · accessed September 9, 2026
Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.