Skip to content
Boilers.caby ROMA Heating & Cooling

U.S. Boiler Company · Independence

U.S. Boiler Company Independence IN6I

The U.S. Boiler Company Independence IN6I is the fourth chimney-vented size with 82.1% AFUE: 175 MBH input with 144 MBH DOE heating capacity and a 108 MBH AHRI net steam rating at 82.1% AFUE, chimney vented (6×15 in chimney).

CurrentCanadian status unknown

Key figures

Max input
175 MBH
Max CSA output
—
AFUE
82.1 %
Min input
—
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

U.S. Boiler Company Independence IN6I in practice

The Independence IN6I is a cast-iron gas steam boiler rated at 175 MBH input. Its row in the Independence Product Data Sheet (Form HYDL07084) prints 144 MBH DOE heating capacity, a 108 MBH AHRI net steam rating (1.333 piping and pickup allowance), 450 steam square feet and 82.1% AFUE.

This is a chimney-vented model using a fuel-saving vent damper and a low-profile rear drafthood, requiring a 6×15 in chimney round chimney 15 feet minimum height and shipping at approximately 555 lb in Packaged, Semi-Pak or Knock-Down configuration. Base standard equipment includes the flame roll-out switch, blocked vent switch, probe-type LWCO and 15 PSI safety valve, with maximum working pressure of 15 PSI steam.

Boilers.ca documents this size at model level from the Independence Product Data Sheet and links the published submittal form. Steam, gas and venting work belongs with a licensed contractor. No official Canadian-sales statement was found, so canadianStatus stays 'unknown'.

Best suited to

  • 175 MBH residential steam loads
  • Homes with an existing 6×15 chimney
  • Owners comparing Independence chimney and PV options by size

Applicability and support

Model number
IN6I
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by U.S. Boiler Company. Units are shown with every value; notes flag conflicting sources or missing figures.

U.S. Boiler Company Independence IN6I specifications
SpecificationValueNote
Input
Input175 MBHMaximum input per the Independence Product Data Sheet ratings table (sea level to 2,000 ft; reduce four percent per 1,000 ft above that, up to 5,000 ft, U.S. only).
Output
DOE heating capacity144 MBHDOE heating capacity per the Independence Product Data Sheet ratings table.
AHRI net steam rating108 MBHAHRI net steam rating per the Independence Product Data Sheet, based on a piping and pickup allowance of 1.333.
Steam square feet450 sq ftSteam square feet per the Independence Product Data Sheet ratings table.
Efficiency
Efficiency (AFUE)82.1 %AFUE per the Independence Product Data Sheet ratings table.
Domestic hot water
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Venting and air
Minimum chimney requirements6×15 in chimneyRound chimney diameter and height measured from top of drafthood to top of chimney per the Independence Product Data Sheet.
VentingChimney vented with vent damper and low-profile rear drafthoodChimney-vented models use a fuel-saving vent damper and low-profile rear drafthood; blocked vent switch and flame roll-out switch are standard.
Physical and connections
Approx. shipping weight555 lbApproximate shipping weight per the Independence Product Data Sheet ratings table.
Operating limits and other
Available configurationsPackaged, Semi-Pak and Knock-DownIndependence boilers are available as Packaged, Semi-Pak and Knock-Down; EZ connect trim sets are available separately for Semi-Pak and Knock-Down.
FuelNatural gas; LP conversion kits available on IN3–IN9 chimney-vented modelsLP conversion kits are available on the IN3I–IN9I chimney-vented models per the ratings table note.

Frequently asked questions

What are the Independence IN6I's ratings?

175 MBH input, 144 MBH DOE heating capacity, a 108 MBH AHRI net steam rating (450 sq ft of steam) and 82.1% AFUE per the Independence Product Data Sheet.

Can the Independence IN6I be converted to LP gas?

Yes — the ratings table notes LP conversion kits are available on the chimney-vented IN3I–IN9I models.

Questions about the U.S. Boiler Company Independence IN6I?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate