Skip to content
Boilers.caby ROMA Heating & Cooling

U.S. Boiler Company · Series

U.S. Boiler Company Independence

The Independence Series is U.S. Boiler Company's cast-iron gas steam boiler, sold chimney-vented (IN3I through IN9I, 62–280 MBH input, up to 82.2% AFUE) or as the Independence PV power-vented option (IN3PVNI through IN6PVNI, 62–175 MBH input, 3" AL29-4C venting) for residential steam systems.

Current seriesunknownNatural gasPropaneresidential

Series facts

Type
non-condensing
Efficiency
82.2% AFUE
Fuel
Natural gas standard; LP conversion kits are available on the IN3I–IN9I chimney-vented models per the ratings table note, and the Independence PV packaged ratings are printed for natural gas.
Venting
Independence is chimney vented with a fuel-saving vent damper and low-profile rear drafthood (4" to 8" round chimney diameter by size, 15 ft minimum height); the Independence PV power-vented option uses a draft-inducing fan with 3" AL29-4C stainless steel venting only, 35 to 45 equivalent feet maximum per the data sheet.
Models documented
11
Warranty
Not verified

Chimney-vented rows print 82.0–82.2% AFUE; Independence PV rows print 82.2% (83.2% on IN3PVNI). The page headline is 'Up 82.2% AFUE'.

About the Independence

The Independence Series is U.S. Boiler Company's gas-fired cast-iron steam boiler, listed under Gas-Fired Water Boilers' sibling steam category on the official site and described as available chimney-vented or in an Independence PV power-vented version for installations without a chimney. The chimney-vented model uses a fuel-saving vent damper and a low-profile rear drafthood that accommodates low overhead areas; the PV option adds a draft-inducing fan that pulls hot gases through the heat exchanger, with a suction pressure switch, thermostat blower relay and vent accessory carton. The page lists up to 82.2% AFUE, 62–280 MBH input across seven sizes, electronic ignition, American-made cast iron sections, stainless-steel burners, a step-opening gas valve and an industrial-quality pressure limit control, with Packaged, Semi-Pak and Knock-Down configurations and EZ connect trim sets sold separately for the latter two.

The Independence Product Data Sheet (Form HYDL07084) prints the complete ratings table. Chimney-vented: IN3I (62 MBH input, 51 MBH DOE heating capacity, 38 MBH AHRI net steam, 158 sq ft, 82.0% AFUE, 4×15 in chimney, 350 lb), IN4I (105/87/65 MBH, 271 sq ft, 82.0%, 5×15, 420 lb), IN5I (140/115/86 MBH, 358 sq ft, 82.0%, 6×15, 485 lb), IN6I (175/144/108 MBH, 450 sq ft, 82.1%, 6×15, 555 lb), IN7I (210/173/130 MBH, 542 sq ft, 82.1%, 7×15, 620 lb), IN8I (245/202/152 MBH, 633 sq ft, 82.2%, 7×15, 690 lb) and IN9I (280/231/173 MBH, 721 sq ft, 82.2%, 8×15, 760 lb). Power-vented: IN3PVNI (62 MBH, 52 MBH, 39 MBH steam, 163 sq ft, 83.2% AFUE, 45 eq ft vent, 355 lb), IN4PVNI (105/87/65 MBH, 271 sq ft, 82.2%, 35 eq ft, 425 lb), IN5PVNI (140/116/87 MBH, 363 sq ft, 82.2%, 35 eq ft, 490 lb) and IN6PVNI (175/145/109 MBH, 454 sq ft, 82.2%, 35 eq ft, 560 lb). Net AHRI steam ratings use a 1.333 piping and pickup allowance; maximum working pressure is 15 PSI steam.

Base standard equipment includes the section assembly, insulated deluxe jacket, base-burner manifold assembly, flame roll-out switch, gas control assembly, canopy, rear drafthood, blocked vent switch and vent damper, with packaged boilers adding the pressure limit, 24V transformer, probe-type LWCO, junction box, thermostat isolating relay, electronic ignition assembly, 15 PSI safety valve, steam gauge, gauge glass, 3/4" drain valve and wiring harness. Boilers.ca documents the seven chimney-vented and four power-vented models at model level from the data sheet; no official Canadian-sales statement was found, so canadianStatus stays 'unknown'.

Highlights

  • Current U.S. Boiler Company gas steam line: IN3I–IN9I chimney vented, IN3PVNI–IN6PVNI power vented
  • 62–280 MBH input; up to 82.2% AFUE (83.2% on IN3PVNI)
  • AHRI net steam ratings 38–173 MBH at a 1.333 piping and pickup allowance
  • Independence PV vents in 3" AL29-4C stainless only, 35–45 equivalent feet
  • Chimney-vented models need a 4"–8" round chimney 15 ft minimum height
  • Packaged, Semi-Pak and Knock-Down configurations (PV available packaged only)
  • Model-level pages published on Boilers.ca; data sheet and submittal form linked here

Models

Independence models

One canonical page per model with input, output and efficiency kept separate.

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
82 %

The U.S. Boiler Company Independence IN3I is the smallest chimney-vented Independence: 62 MBH input with 51 MBH DOE heating capacity and a 38 MBH AHRI net steam rating at 82% AFUE, chimney vented (4×15 in chimney).

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
82 %

The U.S. Boiler Company Independence IN4I is the second chimney-vented size: 105 MBH input with 87 MBH DOE heating capacity and a 65 MBH AHRI net steam rating at 82% AFUE, chimney vented (5×15 in chimney).

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
82 %

The U.S. Boiler Company Independence IN5I is the mid-size chimney-vented model: 140 MBH input with 115 MBH DOE heating capacity and a 86 MBH AHRI net steam rating at 82% AFUE, chimney vented (6×15 in chimney).

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
82.1 %

The U.S. Boiler Company Independence IN6I is the fourth chimney-vented size with 82.1% AFUE: 175 MBH input with 144 MBH DOE heating capacity and a 108 MBH AHRI net steam rating at 82.1% AFUE, chimney vented (6×15 in chimney).

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
82.1 %

The U.S. Boiler Company Independence IN7I is the first size with a 7-inch chimney connector: 210 MBH input with 173 MBH DOE heating capacity and a 130 MBH AHRI net steam rating at 82.1% AFUE, chimney vented (7×15 in chimney).

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
82.2 %

The U.S. Boiler Company Independence IN8I is the second-largest chimney-vented size: 245 MBH input with 202 MBH DOE heating capacity and a 152 MBH AHRI net steam rating at 82.2% AFUE, chimney vented (7×15 in chimney).

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
82.2 %

The U.S. Boiler Company Independence IN9I is the largest chimney-vented Independence: 280 MBH input with 231 MBH DOE heating capacity and a 173 MBH AHRI net steam rating at 82.2% AFUE, chimney vented (8×15 in chimney).

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
83.2 %

The U.S. Boiler Company Independence IN3PVNI is the smallest power-vented model, with the line's highest 83.2% AFUE: 62 MBH input with 52 MBH DOE heating capacity and a 39 MBH AHRI net steam rating at 83.2% AFUE, power vented in 3" AL29-4C stainless.

Natural gasHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
82.2 %

The U.S. Boiler Company Independence IN4PVNI is the second power-vented size: 105 MBH input with 87 MBH DOE heating capacity and a 65 MBH AHRI net steam rating at 82.2% AFUE, power vented in 3" AL29-4C stainless.

Natural gasHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
82.2 %

The U.S. Boiler Company Independence IN5PVNI is the mid-size power-vented model: 140 MBH input with 116 MBH DOE heating capacity and a 87 MBH AHRI net steam rating at 82.2% AFUE, power vented in 3" AL29-4C stainless.

Natural gasHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
82.2 %

The U.S. Boiler Company Independence IN6PVNI is the largest power-vented Independence: 175 MBH input with 145 MBH DOE heating capacity and a 109 MBH AHRI net steam rating at 82.2% AFUE, power vented in 3" AL29-4C stainless.

Natural gasHeating-only

Compare models in this series

Comparison of U.S. Boiler Company Independence IN3I and U.S. Boiler Company Independence IN4I and U.S. Boiler Company Independence IN5I and U.S. Boiler Company Independence IN6I and U.S. Boiler Company Independence IN7I and U.S. Boiler Company Independence IN8I and U.S. Boiler Company Independence IN9I and U.S. Boiler Company Independence IN3PVNI and U.S. Boiler Company Independence IN4PVNI and U.S. Boiler Company Independence IN5PVNI and U.S. Boiler Company Independence IN6PVNI
SpecificationU.S. Boiler Company Independence IN3IU.S. Boiler Company Independence IN4IU.S. Boiler Company Independence IN5IU.S. Boiler Company Independence IN6IU.S. Boiler Company Independence IN7IU.S. Boiler Company Independence IN8IU.S. Boiler Company Independence IN9IU.S. Boiler Company Independence IN3PVNIU.S. Boiler Company Independence IN4PVNIU.S. Boiler Company Independence IN5PVNIU.S. Boiler Company Independence IN6PVNI
input-min———————————
Input62 MBH105 MBH140 MBH175 MBH210 MBH245 MBH280 MBH62 MBH105 MBH140 MBH175 MBH
output-max———————————
Efficiency (AFUE)82 %82 %82 %82.1 %82.1 %82.2 %82.2 %83.2 %82.2 %82.2 %82.2 %
turndown———————————
vent-max-3———————————
vent-max-2———————————
Approx. shipping weight350 lb420 lb485 lb555 lb620 lb690 lb760 lb355 lb425 lb490 lb560 lb

Read the full comparison: U.S. Boiler Company Independence IN3I vs IN4I →

Read the full comparison: U.S. Boiler Company Independence IN3I vs IN3PVNI →

Read the full comparison: U.S. Boiler Company Independence IN3PVNI vs IN4I →

Read the full comparison: U.S. Boiler Company Independence IN4I vs IN4PVNI →

Error codes and alerts

Independence alerts

No alerts documented for this series yet.

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

What is the difference between the Independence and Independence PV?

The Independence is chimney vented with a vent damper and rear drafthood; the Independence PV adds a draft-inducing fan for power venting without a chimney, using 3" AL29-4C stainless steel venting to a maximum of 35–45 equivalent feet depending on size, and is available packaged only.

Which Independence sizes can convert to LP gas?

The ratings table notes LP conversion kits are available on the chimney-vented IN3I–IN9I models; the Independence PV ratings are printed for natural gas, packaged.

Are Independence boilers for steam or water?

The Independence Series is a gas-fired cast-iron steam boiler rated to 15 PSI maximum working pressure; the ratings table prints AHRI net steam ratings and steam square feet. Boilers.ca documents it as a steam line.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate