Skip to content
Boilers.caby ROMA Heating & Cooling

U.S. Boiler Company · Independence

U.S. Boiler Company Independence IN6PVNI

The U.S. Boiler Company Independence IN6PVNI is the largest power-vented Independence: 175 MBH input with 145 MBH DOE heating capacity and a 109 MBH AHRI net steam rating at 82.2% AFUE, power vented in 3" AL29-4C stainless.

CurrentCanadian status unknown

Key figures

Max input
175 MBH
Max CSA output
AFUE
82.2 %
Min input
Natural gasHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

U.S. Boiler Company Independence IN6PVNI in practice

The Independence IN6PVNI is a cast-iron gas steam boiler rated at 175 MBH input. Its row in the Independence Product Data Sheet (Form HYDL07084) prints 145 MBH DOE heating capacity, a 109 MBH AHRI net steam rating (1.333 piping and pickup allowance), 454 steam square feet and 82.2% AFUE.

This is one of the four Independence PV power-vented models: a draft-inducing fan pulls hot gases through the heat exchanger so the boiler can be installed without a chimney, venting through 3" AL29-4C stainless steel only to a maximum of 35 eq ft (3" AL29-4C). It ships packaged at approximately 560 lb with a suction pressure switch, thermostat blower relay and vent accessory carton.

Boilers.ca documents this size at model level from the Independence Product Data Sheet and links the published submittal form. Steam, gas and venting work belongs with a licensed contractor. No official Canadian-sales statement was found, so canadianStatus stays 'unknown'.

Best suited to

  • 175 MBH residential steam loads
  • Homes without a chimney (power-vented installation)
  • Owners comparing Independence chimney and PV options by size

Applicability and support

Model number
IN6PVNI
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by U.S. Boiler Company. Units are shown with every value; notes flag conflicting sources or missing figures.

U.S. Boiler Company Independence IN6PVNI specifications
SpecificationValueNote
Input
Input175 MBHMaximum input per the Independence Product Data Sheet ratings table (sea level to 2,000 ft; reduce four percent per 1,000 ft above that, up to 5,000 ft, U.S. only).
Output
DOE heating capacity145 MBHDOE heating capacity per the Independence Product Data Sheet ratings table.
AHRI net steam rating109 MBHAHRI net steam rating per the Independence Product Data Sheet, based on a piping and pickup allowance of 1.333.
Steam square feet454 sq ftSteam square feet per the Independence Product Data Sheet ratings table.
Efficiency
Efficiency (AFUE)82.2 %AFUE per the Independence Product Data Sheet ratings table.
Domestic hot water
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Venting and air
Vent length (3" AL29-4C only)35 eq ft (3" AL29-4C)Independence PV vent pipe length is listed in equivalent feet; elbows and tees subtract from the total. Approved venting is 3" AL29-4C stainless steel only, as specified in the I&O instructions.
VentingPower vented (draft-inducing fan); 3" AL29-4C stainless steel onlyThe PV option uses a draft-inducing fan pulling hot gases through the heat exchanger, with suction pressure switch, thermostat blower relay and vent accessory carton.
Physical and connections
Approx. shipping weight560 lbApproximate shipping weight per the Independence Product Data Sheet ratings table.
Operating limits and other
Available configurationsPackaged onlyIndependence PV boilers are available as Packaged per the Product Data Sheet.
FuelNatural gas (packaged)Independence PV ratings are printed for natural gas, packaged.

Frequently asked questions

What are the Independence IN6PVNI's ratings?

175 MBH input, 145 MBH DOE heating capacity, a 109 MBH AHRI net steam rating (454 sq ft of steam) and 82.2% AFUE per the Independence Product Data Sheet.

Can the Independence IN6PVNI be converted to LP gas?

The Independence PV ratings are printed for natural gas, packaged; LP conversion is documented for the chimney-vented IN3I–IN9I models, not the PV line.

Questions about the U.S. Boiler Company Independence IN6PVNI?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate