Utica Boilers · CuB Series (CCB-150 / CHB-100/130)
Utica CuB CCB-150
The Utica CuB CCB-150 is the combination model of the CuB Series: a copper-heat-exchanger, atmospheric gas boiler firing 50–150 MBH for 130 MBH heating capacity and a 110 MBH net AHRI water rating at 85% AFUE, with a stainless brazed-plate DHW heat exchanger delivering 6.3 GPM at a 40 °F rise.
Key figures
- Max input
- 150 MBH
- Max CSA output
- —
- AFUE
- 85 %
- Min input
- 50 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Utica CuB CCB-150 in practice
The CuB CCB-150 is the combination ("combi") model of Utica's CuB Series, documented on the live CuB product page and in the CCB 150 submittal. Its sea-level ratings table prints 50–150 MBH input, 130 MBH heating capacity, a 110 MBH net AHRI water rating (1.15 allowance) and 85% AFUE on a COPPER tube-and-fin heat exchanger with atmospheric combustion — a non-condensing design despite the 'modulating gas boiler' nameplate.
Domestic hot water is produced through a stainless steel brazed-plate heat exchanger rated 6.3 GPM at a 40 °F rise and 3.6 GPM at a 70 °F rise, with boiler water content of 0.396 gallons; the control adds a DHW mode with priority through an automatic 3-way diverting valve. The boiler is wall hung (optional floor stand), ASME 'H' stamped to 43.5 psig with a 30 psig relief valve, vents Category I or Category III, and runs on 120 V / 60 Hz with a factory-wired cord and internal circulator.
Utica prints a 10-year limited heat exchanger warranty and a 2-year limited parts warranty. Boilers.ca records the CuB line as a legacy listing: the page and current documents are live but the line is absent from Utica's category cards. No official Canadian-sales statement was found, so canadianStatus stays 'unknown'; gas, venting and combustion work belongs with a licensed contractor against the CCB 150 IOM Rev. H.
Best suited to
- Homes whose heat loss and hot-water draw fit a 150 MBH combi
- High-temperature retrofits replacing a tank plus boiler with one wall-hung appliance
- Projects needing Category I chimney or Category III horizontal venting options
Applicability and support
- Model number
- CCB-150
- Canadian availability
- unknown
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Utica Boilers. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input rate, minimum | 50 MBH | Minimum input per the sea-level ratings table in the official CuB submittal. |
| Input rate, maximum | 150 MBH | Maximum input per the sea-level ratings table; the gas valve modulates from 100% to 33% of input. |
| Output | ||
| Heating capacity | 130 MBH | Heating capacity per the sea-level ratings table (DOE test procedures). |
| Net AHRI rating, water | 110 MBH | Net AHRI water rating based on a piping and pickup allowance of 1.15 per the submittal. |
| Efficiency | ||
| Efficiency (AFUE) | 85 % | AFUE per the sea-level ratings table; the line is non-condensing with a copper tube-and-fin heat exchanger. |
| Domestic hot water | ||
| Domestic hot water | Stainless steel brazed-plate heat exchanger for potable DHW; 6.3 GPM at a 40 °F rise and 3.6 GPM at a 70 °F rise | As printed on the CCB-150 submittal; boiler water content 0.396 gallons and the control provides an additional DHW mode with DHW priority. |
| Venting and air | ||
| Venting | Category I or Category III (chimney or horizontal); direct-vent adapter and concentric termination kit listed as options | The spec sheet states the boiler is certified for Category I and Category III operation and capable of venting 65 ft equivalent length in 3 in. stainless pipe for Category III applications. |
| Physical and connections | ||
| Heat exchanger | Copper tube with copper fins, stainless steel support plates | Per the official CuB spec sheet; ASME 'H' stamped with a 43.5 psig maximum allowable working pressure and a 30 psig relief valve. |
| Mounting | Wall hung; optional floor mounting stand | Per the spec sheet; an optional floor base kit is listed among the documents. |
| Electrical | ||
| Power supply | 120 V / 60 Hz, 12 A minimum circuit | Factory-wired cord with male plug, 6 ft long; internal factory-installed circulator pump. |
| Operating limits and other | ||
| Control | PCB integral controller with LCD digital display and graphical interface | Modulating control with supply-temperature sensing, outdoor-air reset curves, indirect-tank temperature display, LWCO input and DHW priority via an automatic 3-way diverting valve (spec sheet and product page). |
| Warranty | 10-year limited CH heat exchanger and 2-year limited parts | As printed in the CuB spec sheet and product page. |
Manuals
Alerts documented for this model
None documented yet.
Frequently asked questions
What are the CuB CCB-150 ratings?
50–150 MBH input, 130 MBH heating capacity, a 110 MBH net AHRI water rating and 85% AFUE per the official sea-level ratings table.
How much hot water does the CCB-150 deliver?
The CCB-150's brazed-plate DHW heat exchanger is rated 6.3 GPM at a 40 °F rise and 3.6 GPM at a 70 °F rise per the submittal.
Is the CuB CCB-150 a condensing boiler?
No — the official 85% AFUE rating with a copper tube-and-fin heat exchanger and atmospheric combustion describes a non-condensing design, despite the product nameplate reading 'modulating gas boiler'.
Questions about the Utica CuB CCB-150?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- Utica Boilers — Modulating Gas Boiler, CuB product page · accessed September 9, 2026
- CuB CCB 150 Submittal (sea-level ratings table) · accessed September 9, 2026
- CuB CCB 150 IOM Rev. H (PN 240010632) · accessed September 9, 2026
Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.