Utica CuB CHB-130

The Utica CuB CHB-130 is a heating-only model of the CuB Series: a copper-heat-exchanger, atmospheric gas boiler firing 43.5–130 MBH for 110 MBH heating capacity and a 96 MBH net AHRI water rating at 85% AFUE, with dedicated connections for an indirect water heater.

CurrentCanadian status unknown

Key figures

Max input
130 MBH
Max CSA output
AFUE
85 %
Min input
43.5 MBH
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Utica CuB CHB-130 in practice

The CuB CHB-130 is a space-heating-only model of Utica's CuB Series, documented on the live CuB product page and in the CHB submittal Rev. D. Its sea-level ratings table prints 43.5–130 MBH input, 110 MBH heating capacity, a 96 MBH net AHRI water rating (1.15 allowance) and 85% AFUE on a COPPER tube-and-fin heat exchanger with atmospheric combustion — a non-condensing design despite the 'modulating gas boiler' nameplate.

The CHB models provide dedicated domestic hot water connections for adding an indirect water heater plus a wired sensor for indirect-tank control and temperature reporting. The boiler is wall hung (optional floor stand), ASME 'H' stamped to 43.5 psig with a 30 psig relief valve, vents Category I or Category III, and runs on 120 V / 60 Hz with a factory-wired cord and internal circulator; the gas valve modulates from 100% to 33% of input.

Utica prints a 10-year limited heat exchanger warranty and a 2-year limited parts warranty. Boilers.ca records the CuB line as a legacy listing: the page and current documents are live but the line is absent from Utica's category cards. No official Canadian-sales statement was found, so canadianStatus stays 'unknown'; gas, venting and combustion work belongs with a licensed contractor against the CHB 100-150 IOM Rev. G.

Best suited to

  • Homes whose heat-loss calculation fits inside 130 MBH of input
  • Heating-only systems pairing the boiler with an indirect water heater
  • High-temperature retrofits that suit a copper, non-condensing heat exchanger

Applicability and support

Model number
CHB-130
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Utica Boilers. Units are shown with every value; notes flag conflicting sources or missing figures.

Utica CuB CHB-130 specifications
SpecificationValueNote
Input
Input rate, minimum43.5 MBHMinimum input per the sea-level ratings table in the official CuB submittal.
Input rate, maximum130 MBHMaximum input per the sea-level ratings table; the gas valve modulates from 100% to 33% of input.
Output
Heating capacity110 MBHHeating capacity per the sea-level ratings table (DOE test procedures).
Net AHRI rating, water96 MBHNet AHRI water rating based on a piping and pickup allowance of 1.15 per the submittal.
Efficiency
Efficiency (AFUE)85 %AFUE per the sea-level ratings table; the line is non-condensing with a copper tube-and-fin heat exchanger.
Domestic hot water
Domestic hot waterHeating-only boiler with dedicated DHW connections for an indirect water heaterThe CHB models provide dedicated connections plus a wired sensor for indirect-tank control and temperature reporting (spec sheet).
Venting and air
VentingCategory I or Category III (chimney or horizontal); direct-vent adapter and concentric termination kit listed as optionsThe spec sheet states the boiler is certified for Category I and Category III operation and capable of venting 65 ft equivalent length in 3 in. stainless pipe for Category III applications.
Physical and connections
Heat exchangerCopper tube with copper fins, stainless steel support platesPer the official CuB spec sheet; ASME 'H' stamped with a 43.5 psig maximum allowable working pressure and a 30 psig relief valve.
MountingWall hung; optional floor mounting standPer the spec sheet; an optional floor base kit is listed among the documents.
Electrical
Power supply120 V / 60 Hz, 12 A minimum circuitFactory-wired cord with male plug, 6 ft long; internal factory-installed circulator pump.
Operating limits and other
ControlPCB integral controller with LCD digital display and graphical interfaceModulating control with supply-temperature sensing, outdoor-air reset curves, indirect-tank temperature display, LWCO input and DHW priority via an automatic 3-way diverting valve (spec sheet and product page).
Warranty10-year limited CH heat exchanger and 2-year limited partsAs printed in the CuB spec sheet and product page.

Frequently asked questions

What are the CuB CHB-130 ratings?

43.5–130 MBH input, 110 MBH heating capacity, a 96 MBH net AHRI water rating and 85% AFUE per the official sea-level ratings table.

Does the CHB-130 make domestic hot water?

Not directly — the CHB models are heating-only with dedicated connections and a wired sensor for an indirect water heater.

Is the CuB CHB-130 a condensing boiler?

No — the official 85% AFUE rating with a copper tube-and-fin heat exchanger and atmospheric combustion describes a non-condensing design, despite the product nameplate reading 'modulating gas boiler'.

Questions about the Utica CuB CHB-130?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate