Skip to content
Boilers.caby ROMA Heating & Cooling

Utica Boilers · Series

Utica Boilers CuB Series (CCB-150 / CHB-100/130)

The CuB Series is Utica's modulating gas hot-water boiler family on a COPPER heat exchanger: the CCB-150 combi and the heating-only CHB-130/CHB-100, at 85% AFUE with atmospheric combustion and chimney or horizontal venting. The official page is live with current documents but the line is absent from Utica's category cards, so it is recorded as a legacy listing (documented and serviceable, not shown in the current category).

Current seriesunknownNatural gasPropaneresidential

Series facts

Type
non-condensing
Efficiency
85% AFUE
Fuel
Natural gas or propane; an LP gas conversion kit is listed among the page options.
Venting
Atmospheric with chimney or horizontal vent; the page lists a horizontal vent termination concentric kit and a direct vent adapter among the accessories.
Models documented
4

85% AFUE as printed on the CuB product page. The heat exchanger is copper and combustion is atmospheric — the design is non-condensing despite the 'modulating' nameplate.

About the CuB Series (CCB-150 / CHB-100/130)

The CuB Series is Utica's modulating gas hot-water boiler family, positioned on the product page for heating-only and combination ('combi') heating and domestic hot water applications, including single-family homes, apartments and multi-family dwellings with individual appliances, and retrofits for high-temperature systems. The page prints 85% AFUE, a COPPER heat exchanger, atmospheric combustion, chimney or horizontal venting and hot-water boiler type; a fan and gas valve modulate between 33% and 100% of capacity, and the advanced controls provide a digital display with temperature indication, diagnostics and status symbols for heating mode, burner on and burner modulation level.

Two configurations are documented: the combination CCB-150 combi, available at 150 MBH with a stainless steel brazed-plate heat exchanger for potable domestic hot water and an additional DHW mode in the control; and the space-heating-only CHB models, available in 100 MBH and 130 MBH with dedicated domestic hot water connections for adding an indirect water heater. Options include an LP gas conversion kit, a horizontal vent termination concentric kit, a floor stand kit, an indirect hot water tank sensor and an outdoor air temperature reset sensor. Utica prints a 10-year limited copper heat exchanger warranty and a 2-year limited parts warranty.

Status note: the CuB page remains live with current documents — the CCB 150 IOM Rev. H, the CHB 100-150 IOM Rev. G, spec sheets, submittals, application guides, user manuals and warranty — but the line does not appear on Utica's category cards, so the utica2 research records it as a legacy listing rather than part of the current catalogue. Despite the 'modulating gas boiler' nameplate, the official 85% AFUE rating with a copper heat exchanger and atmospheric combustion describes a NON-condensing design, and Boilers.ca records it that way. Gas, venting and combustion work belongs with a licensed contractor.

Highlights

  • Copper heat exchanger, atmospheric combustion, chimney or horizontal vent — a NON-condensing design despite the 'modulating' nameplate
  • 85% AFUE with fan and gas valve modulating between 33% and 100% of capacity
  • CCB-150 combi (150 MBH) with a stainless steel brazed-plate DHW heat exchanger
  • CHB-100 and CHB-130 heating-only sizes with dedicated DHW connections for an indirect water heater
  • Page live with current documents (CCB 150 IOM Rev. H; CHB 100-150 IOM Rev. G) but absent from Utica's category cards — legacy listing
  • 10-year limited copper heat exchanger warranty and 2-year limited parts warranty

10-year limited copper heat exchanger warranty and 2-year limited parts warranty, as printed on the CuB product page.

Models

CuB Series (CCB-150 / CHB-100/130) models

One canonical page per model with input, output and efficiency kept separate.

Utica Boilers

Utica CuB CCB-150

CurrentCanadian status unknown
Input
50–150 MBH
Output (max)
AFUE
85 %

The Utica CuB CCB-150 is the combination model of the CuB Series: a copper-heat-exchanger, atmospheric gas boiler firing 50–150 MBH for 130 MBH heating capacity and a 110 MBH net AHRI water rating at 85% AFUE, with a stainless brazed-plate DHW heat exchanger delivering 6.3 GPM at a 40 °F rise.

Natural gasPropaneCombi

Utica Boilers

Utica CuB CHB-100

CurrentCanadian status unknown
Input
31.5–100 MBH
Output (max)
AFUE
85 %

The Utica CuB CHB-100 is a heating-only model of the CuB Series: a copper-heat-exchanger, atmospheric gas boiler firing 31.5–100 MBH for 85 MBH heating capacity and a 73 MBH net AHRI water rating at 85% AFUE, with dedicated connections for an indirect water heater.

Natural gasPropaneHeating-only

Utica Boilers

Utica CuB CHB-130

CurrentCanadian status unknown
Input
43.5–130 MBH
Output (max)
AFUE
85 %

The Utica CuB CHB-130 is a heating-only model of the CuB Series: a copper-heat-exchanger, atmospheric gas boiler firing 43.5–130 MBH for 110 MBH heating capacity and a 96 MBH net AHRI water rating at 85% AFUE, with dedicated connections for an indirect water heater.

Natural gasPropaneHeating-only

Utica Boilers

Utica CuB CHB-150

CurrentCanadian status unknown
Input
50–150 MBH
Output (max)
AFUE
85 %

The Utica CuB CHB-150 is a heating-only model of the CuB Series: a copper-heat-exchanger, atmospheric gas boiler firing 50–150 MBH for 130 MBH heating capacity and a 110 MBH net AHRI water rating at 85% AFUE, with dedicated connections for an indirect water heater.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Utica CuB CCB-150 and Utica CuB CHB-100 and Utica CuB CHB-130 and Utica CuB CHB-150
SpecificationUtica CuB CCB-150Utica CuB CHB-100Utica CuB CHB-130Utica CuB CHB-150
Input rate, minimum50 MBH31.5 MBH43.5 MBH50 MBH
Input rate, maximum150 MBH100 MBH130 MBH150 MBH
output-max
Efficiency (AFUE)85 %85 %85 %85 %
turndown
vent-max-3
vent-max-2
weight

Read the full comparison: Utica CuB CHB-100 vs CHB-130

Read the full comparison: Utica CuB CHB-130 vs CCB-150

Read the full comparison: Utica CuB CCB-150 vs CHB-150

Read the full comparison: Utica CuB CHB-100 vs CCB-150

Error codes and alerts

CuB Series (CCB-150 / CHB-100/130) alerts

No alerts documented for this series yet.

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

Is the Utica CuB a condensing boiler?

No. The official page prints 85% AFUE with a copper heat exchanger and atmospheric combustion — a non-condensing design. The 'modulating gas boiler' title refers to its 33–100% capacity modulation, not to condensing operation.

What models are in the CuB Series?

The CCB-150 combination (combi) model at 150 MBH with a stainless steel brazed-plate domestic hot water heat exchanger, and the heating-only CHB models at 100 MBH and 130 MBH with dedicated DHW connections for an indirect water heater.

Is the CuB Series current?

The page is live and carries current documents (CCB 150 IOM Rev. H, CHB 100-150 IOM Rev. G), but the line does not appear on Utica's category cards, so it is recorded as a legacy listing — documented and serviceable rather than shown in the current category.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate