Utica Boilers SVB Series 4 (SVB-2 to SVB-6)

The SVB Series 4 is Utica's current induced-draft cast-iron water boiler line: five sell-sheet sizes SVB-2 through SVB-6 from 42.5 to 187.5 MBH at 84.0–84.4% AFUE, ventable through a chimney or sidewall, with a Honeywell high-limit/electronic-ignition control, titanium burners and a 20-year non-prorated residential warranty.

Current seriesunknownNatural gasPropaneresidential

Series facts

Type
non-condensing
Efficiency
84.4% AFUE
Fuel
Natural gas or propane; natural-gas and propane conversion kits plus high-altitude conversion kits are listed as options on the product page.
Venting
Induced-draft fan allows flue gases to be pulled through the boiler and exhausted through a chimney or sidewall vent; 4" chimney / 3" sidewall on SVB-2 through SVB-5, 4"/4" on SVB-6.
Models documented
5

Up to 84.4% AFUE as printed on the product page; the official sell-sheet table prints 84.4% for the SVB-2 and 84.0% for SVB-3 through SVB-6.

About the SVB Series 4 (SVB-2 to SVB-6)

The SVB Series 4 is Utica's current cast-iron water boiler line with an induced-draft fan that pulls flue gases through the boiler and exhausts them through a chimney or sidewall vent. Checked on the official Gas Boilers category page on September 9, 2026, its card carries the 'Current' tag. Utica describes the line as available in six sizes from 42.5 MBH to 187.5 MBH with an AFUE of up to 84.4%, a Honeywell high-limit/electronic-ignition control with digital temperature display and diagnostics, a textured paint jacket and a limited lifetime warranty for residential applications.

The official sell sheet (PN 240009708 Rev. 09/04/26) prints five rows: SVB-2 (42.5 MBH input, 36 MBH heating capacity, 31 MBH net water, 84.4% AFUE, 4" chimney / 3" sidewall vent, 1.75 gal water, 11 × 29 × 23¼ in, 225 lb), SVB-3 (75.0/63/55/84.0, 4"/3", 3 gal, 14¼ × 29 × 23¼, 265), SVB-4 (112.5/95/82/84.0, 4"/3", 4.25 gal, 17½ × 29 × 23¼, 322), SVB-5 (150.0/127/109/84.0, 4"/3", 5.5 gal, 20¾ × 29 × 23¼, 370) and SVB-6 (187.5/158/135/84.0, 4"/4", 6.75 gal, 24 × 29 × 23¼, 431).

Official discrepancy to note: the product page text says 'six sizes from 42.5 MBH to 187.5 MBH' while the current sell sheet prints five rows (SVB-2 through SVB-6) — both official wordings are captured, and Boilers.ca models the five printed rows. The cast-iron sections use cast-iron push nipples; burners are titanium composite with a 24 V gas control system; safety devices include a flame roll-out safety shut-off (fuse link) and a pressure switch (vent safety shutoff) with a spare fuse link included. Utica prints a 20-year non-prorated limited residential warranty. Gas, venting and combustion work belongs with a licensed contractor.

Highlights

  • Current on Utica's Gas Boilers category page (checked 2026-09-09)
  • Five sell-sheet sizes modelled — SVB-2 through SVB-6 — inputs 42.5–187.5 MBH, AFUE 84.0–84.4%
  • Official page/sell-sheet size-count discrepancy captured (page says six sizes; sell sheet prints five rows)
  • Induced-draft fan vents through a chimney or sidewall; 4"/3" venting on SVB-2 through SVB-5, 4"/4" on SVB-6
  • Honeywell high-limit/electronic-ignition control with digital display and diagnostics
  • 20-year non-prorated limited residential warranty; titanium burners and cast-iron push nipples

20-year non-prorated limited warranty (residential) as printed on the official SVB Series 4 product page.

Models

SVB Series 4 (SVB-2 to SVB-6) models

One canonical page per model with input, output and efficiency kept separate.

Utica Boilers

Utica SVB-2

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84.4 %

The Utica SVB-2 is a size in the current SVB Series 4 cast-iron water line: 42.5 MBH fixed input, 36 MBH heating capacity, a 31 MBH net AHRI water rating and 84.4% AFUE, with induced-draft chimney (4") or sidewall (3") venting. It is tagged 'Current' on Utica's Gas Boilers category page.

Natural gasPropaneHeating-only

Utica Boilers

Utica SVB-3

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84 %

The Utica SVB-3 is a size in the current SVB Series 4 cast-iron water line: 75 MBH fixed input, 63 MBH heating capacity, a 55 MBH net AHRI water rating and 84% AFUE, with induced-draft chimney (4") or sidewall (3") venting. It is tagged 'Current' on Utica's Gas Boilers category page.

Natural gasPropaneHeating-only

Utica Boilers

Utica SVB-4

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84 %

The Utica SVB-4 is a size in the current SVB Series 4 cast-iron water line: 112.5 MBH fixed input, 95 MBH heating capacity, a 82 MBH net AHRI water rating and 84% AFUE, with induced-draft chimney (4") or sidewall (3") venting. It is tagged 'Current' on Utica's Gas Boilers category page.

Natural gasPropaneHeating-only

Utica Boilers

Utica SVB-5

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84 %

The Utica SVB-5 is a size in the current SVB Series 4 cast-iron water line: 150 MBH fixed input, 127 MBH heating capacity, a 109 MBH net AHRI water rating and 84% AFUE, with induced-draft chimney (4") or sidewall (3") venting. It is tagged 'Current' on Utica's Gas Boilers category page.

Natural gasPropaneHeating-only

Utica Boilers

Utica SVB-6

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84 %

The Utica SVB-6 is a size in the current SVB Series 4 cast-iron water line: 187.5 MBH fixed input, 158 MBH heating capacity, a 135 MBH net AHRI water rating and 84% AFUE, with induced-draft chimney (4") or sidewall (4") venting. It is tagged 'Current' on Utica's Gas Boilers category page.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Utica SVB-2 and Utica SVB-3 and Utica SVB-4 and Utica SVB-5 and Utica SVB-6
SpecificationUtica SVB-2Utica SVB-3Utica SVB-4Utica SVB-5Utica SVB-6
input-min—————
input-max—————
output-max—————
AFUE84.4 %84 %84 %84 %84 %
turndown—————
vent-max-3—————
vent-max-2—————
weight—————

Read the full comparison: Utica SVB-2 vs SVB-3 →

Read the full comparison: Utica SVB-3 vs SVB-4 →

Read the full comparison: Utica SVB-4 vs SVB-5 →

Read the full comparison: Utica SVB-5 vs SVB-6 →

Error codes and alerts

SVB Series 4 (SVB-2 to SVB-6) alerts

No alerts documented for this series yet.

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

What sizes does the Utica SVB Series 4 cover?

The current sell sheet prints five sizes: SVB-2 (42.5 MBH input), SVB-3 (75.0), SVB-4 (112.5), SVB-5 (150.0) and SVB-6 (187.5), with 84.4% AFUE on the SVB-2 and 84.0% on the rest. The product page text says 'six sizes' — the official discrepancy is flagged on this record.

Does the SVB Series 4 need a chimney?

No — the induced-draft fan allows flue gases to be exhausted through a chimney or sidewall vent, which Utica positions as an advantage for new or existing homes with or without a chimney. Chimney venting is 4" on all five printed sizes; sidewall is 3" on SVB-2 through SVB-5 and 4" on SVB-6.

Is the SVB Series 4 a condensing boiler?

No. It is a non-condensing cast-iron boiler at 84.0–84.4% AFUE with an induced-draft fan and a chimney or sidewall exhaust — not a condensing design.

What warranty does Utica print for the SVB Series 4?

A 20-year non-prorated limited warranty for residential applications, as printed on the official product page.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate