Skip to content
Boilers.caby ROMA Heating & Cooling

Weil-McLain · AquaBalance

Weil-McLain AquaBalance AB-120C

The AB-120C is the mid-size AquaBalance Series 2 combi, discontinued in Canada: 120 MBH CSA input, 112 MBH DOE heating capacity and an integrated DHW module at 95% AFUE, in an 80 lb wall-mounted stainless steel unit.

DiscontinuedHistorically in Canada

Key figures

Max input
120 MBH
Max CSA output
112 MBH
AFUE
95 %
Min input
—
Natural gasPropaneCombiresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Weil-McLain AquaBalance AB-120C in practice

The AB-120C fires at 120 MBH CSA input for 112 MBH of DOE heating capacity and a 97 MBH net AHRI rating at 95% AFUE, adding the combi's DHW flat plate heat exchanger, 3-way valve and internal 3-speed circulator to the shared Series 2 platform. Weil-McLain's US page promotes the boiler's 1" diameter ASME-certified 316L stainless steel single-tube heat exchanger, ENERGY STAR certification and SCAQMD-compliant low-NOx firing around a digital Honeywell control.

Weil-McLain Canada sold the AquaBalance with combi and heat-only pages, both now on the site's Discontinued menu with inputs of 80/120/155 MBH and up to 95% AFUE. This combi variant is the model the CA combi page markets for space heating plus domestic hot water — up to 4 GPM at a 70°F rise as a range claim — while the CA page's 109 MBH output figure for the 120 differs from the 112 MBH DOE heating capacity of the US Series 2 documents.

Best suited to

  • Homes sized around 120 MBH that want one wall-mounted appliance for heat and hot water
  • Retrofit projects in the limited-space installations the AquaBalance was marketed for
  • Documenting the discontinued-in-Canada AquaBalance combi range against Series 2 ratings

Applicability and support

Model number
AB-120C
Canadian availability
historical
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Weil-McLain. Units are shown with every value; notes flag conflicting sources or missing figures.

Weil-McLain AquaBalance AB-120C specifications
SpecificationValueNote
Input
Input, maximum120 MBHCSA input (maximum).
Output
DOE heating capacity112 MBHUS Series 2 DOE heating capacity; the CA discontinued page prints 109 MBH output for this size (see the editor note).
Net AHRI water rating97 MBHNet AHRI water rating per the US Series 2 product page table.
Efficiency
Efficiency (AFUE)95 %95% AFUE per the US Series 2 page; the CA discontinued page lists up to 95%.
Domestic hot water
Domestic hot waterIntegrated combi: built-in DHW flat plate heat exchanger with a 3-way valve and an internal 3-speed circulatorThe CA discontinued combi page claims up to 4 GPM of domestic hot water at a 70°F rise as a range figure; the US Series 2 page ties the 4 GPM claim to the 155 combi model.
Venting and air
Venting2" or 3" PVC, CPVC, polypropylene or stainless steel (Category IV)Canada: install per CAN/CSA B149.1 or B149.2 with a ULC S636-compliant vent kit.
Physical and connections
Weight80 lbApprox. shipping weight per the US Series 2 product page.
Gas connection1/2" NPTGas connection per the Series 2 brochure connection chart.
Heating water connections3/4" NPTHeating supply and return 3/4" NPT on the 80/120 sizes, 1" NPT on the 155; DHW inlet and outlet are 1/2" NPT on this 120 combi per the Series 2 brochure connection chart.
Operating limits and other
Turndown10:110:1 modulation per the notes on both CA discontinued AquaBalance pages.
FuelNatural gas or propanePropane requires a conversion kit per the CA product page.

Frequently asked questions

What are the AB-120C's ratings?

120 MBH CSA input, 112 MBH DOE heating capacity, a 97 MBH net AHRI rating and 95% AFUE, at an 80 lb shipping weight per the US Series 2 product page.

Why does the CA page list 109 MBH where the US page lists 112 MBH?

The CA discontinued AquaBalance page prints outputs of 73/109/143 MBH for the 80/120/155, while the US Series 2 page and manual print DOE heating capacities of 75/112/144 MBH. Boilers.ca treats the Series 2 figures as the ratings for this generation.

Does the AB-120C produce domestic hot water?

Yes. The AB-120C is a combi with a built-in DHW flat plate heat exchanger, so it produces heat and on-demand hot water from one appliance.

Questions about the Weil-McLain AquaBalance AB-120C?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate