The AB-80C is the combi entry of the AquaBalance Series 2 wall-mount line that weil-mclain.ca lists under Discontinued: 80 MBH CSA input, 75 MBH DOE heating capacity and an integrated DHW module at 95% AFUE in a 77 lb stainless steel unit.
Key figures
- Max input
- 80 MBH
- Max CSA output
- 75 MBH
- AFUE
- 95 %
- Min input
- —
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Weil-McLain AquaBalance AB-80C in practice
The AB-80C pairs the smallest AquaBalance Series 2 platform — 80 MBH CSA input, 75 MBH DOE heating capacity, a 65 MBH net AHRI rating at 95% AFUE — with the built-in DHW flat plate heat exchanger, 3-way valve and internal 3-speed circulator, so the same 77 lb wall-mounted boiler heats the house and makes hot water on demand. Weil-McLain's US page describes the platform around a 1" diameter ASME-certified 316L stainless steel single-tube heat exchanger, ENERGY STAR certification and SCAQMD-compliant low-NOx firing, with a digital Honeywell control and a 3-in-1 vent adapter for PVC, CPVC, polypropylene or stainless pipe.
The CA discontinued pages list the same three inputs — 80, 120 and 155 MBH — for the combi and heat-only entries at up to 95% AFUE with 10:1 modulation, and market the combi for space heating plus domestic hot water (up to 4 GPM at a 70°F rise on the US page's 155 combi claim). The CA combi page prints 73 MBH output for the 80 size against the US Series 2 page's 75 MBH DOE heating capacity, a Canadian-era figure Boilers.ca flags rather than repeats as the Series 2 rating.
Best suited to
- Smaller homes and apartments that want heat plus on-demand hot water from one wall-mounted unit
- Retrofit and limited-space installations the CA discontinued page lists for the AquaBalance
- Buyers documenting the discontinued-in-Canada AquaBalance line against US Series 2 literature
Applicability and support
- Model number
- AB-80C
- Canadian availability
- historical
- Production status
- discontinued
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Not verified
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Weil-McLain. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, maximum | 80 MBH | CSA input (maximum). |
| Output | ||
| DOE heating capacity | 75 MBH | US Series 2 DOE heating capacity; the CA discontinued page prints 73 MBH output for this size (see the editor note). |
| Net AHRI water rating | 65 MBH | Net AHRI water rating per the US Series 2 product page table. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | 95% AFUE per the US Series 2 page; the CA discontinued page lists up to 95%. |
| Domestic hot water | ||
| Domestic hot water | Integrated combi: built-in DHW flat plate heat exchanger with a 3-way valve and an internal 3-speed circulator | The CA discontinued combi page claims up to 4 GPM of domestic hot water at a 70°F rise as a range figure; the US Series 2 page ties the 4 GPM claim to the 155 combi model. |
| Venting and air | ||
| Venting | 2" or 3" PVC, CPVC, polypropylene or stainless steel (Category IV) | Canada: install per CAN/CSA B149.1 or B149.2 with a ULC S636-compliant vent kit. |
| Physical and connections | ||
| Weight | 77 lb | Approx. shipping weight per the US Series 2 product page. |
| Gas connection | 1/2" NPT | Gas connection per the Series 2 brochure connection chart. |
| Heating water connections | 3/4" NPT | Heating supply and return 3/4" NPT on the 80/120 sizes, 1" NPT on the 155; DHW inlet and outlet are 1/2" NPT on this 80 combi per the Series 2 brochure connection chart. |
| Operating limits and other | ||
| Turndown | 10:1 | 10:1 modulation per the notes on both CA discontinued AquaBalance pages. |
| Fuel | Natural gas or propane | Propane requires a conversion kit per the CA product page. |
Manuals
- AquaBalance Series 2 Boiler Manual, 550-100-325/0924550-100-325/0924 · 2024-09
Alerts documented for this model
Frequently asked questions
What are the AB-80C's ratings?
80 MBH CSA input, 75 MBH DOE heating capacity, a 65 MBH net AHRI rating and 95% AFUE, at a 77 lb shipping weight per the US Series 2 product page.
Why does the CA page list 73 MBH where the US page lists 75 MBH?
The CA discontinued AquaBalance page prints outputs of 73/109/143 MBH for the 80/120/155, while the US Series 2 page and manual print DOE heating capacities of 75/112/144 MBH. Boilers.ca treats the Series 2 figures as the ratings for this generation.
How much hot water does the AB-80C deliver?
The CA discontinued combi page markets up to 4 GPM at a 70°F rise for the range; the US Series 2 page ties the 4 GPM figure to the 155 combi model.
Questions about the Weil-McLain AquaBalance AB-80C?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
Sources and verification
- Weil-McLain Canada — AquaBalance (Combi), discontinued · accessed September 8, 2026
- AquaBalance Series 2 Boiler Manual 550-100-325/0924 · 550-100-325/0924 · accessed September 8, 2026
Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.