Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

Burnham Alpine ALP080B vs ALP105B

Verdict in brief

The ALP080B and ALP105B are the two smallest Alpines, both 95.0% AFUE condensing boilers with identical 3" venting (135 ft, 2" option to 60 ft), 1/2" FPT gas and 1" FPT water connections. The 105B adds 25 MBH of input ceiling (105 vs 80), lifting DOE heating capacity from 72 to 96 MBH and the net AHRI rating from 63 to 83 MBH, for 18 lb more shipping weight.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Burnham Alpine ALP080B and Burnham Alpine ALP105B
SpecificationBurnham Alpine ALP080BBurnham Alpine ALP105B
Input, minimum16 MBH21 MBH
Input, maximum80 MBH105 MBH
DOE heating capacity72 MBH96 MBH
Net AHRI water rating63 MBH83 MBH
Efficiency (AFUE)95 %95 %
Vent connection3" CPVC/PVC (optional 2" reduced-length build)3" CPVC/PVC (optional 2" reduced-length build)
Shipping weight137 lb155 lb
Gas connection1/2" FPT1/2" FPT
Supply/return connections1" FPT1" FPT
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heaterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater

What actually separates them

Both models are 95.0% AFUE, 5:1-modulating, condensing Alpines on the stainless steel coil heat exchanger with the Sage2.X control, identical NG/LP inputs and the same Category IV 3" CPVC/PVC venting limits — 135 ft maximum equivalent intake and vent, with the reduced 2" option to 60 ft on both sizes.

The ALP105B exists for capacity: its 105 MBH maximum input (21 MBH minimum) against the 080B's 80 MBH maximum (16 MBH minimum) prints 96 MBH DOE heating capacity and an 83 MBH net AHRI rating versus 72 and 63 MBH on the 080B.

Physically the two are near twins — both connect on 1/2" FPT gas and 1" FPT supply/return — with the 105B weighing 155 lb shipping against the 080B's 137 lb. Neither makes domestic hot water; the choice follows a heat-loss calculation between roughly 72 and 96 MBH of required DOE capacity.

CurrentCanadian status unknown
Input
16–80 MBH
Output (max)
—
AFUE
95 %

The Burnham Alpine ALP080B is the smallest Alpine: 16 to 80 MBH input at 95.0% AFUE with 5:1 modulation, wall-hung or floor-standing, vented in 3" CPVC/PVC (2" option to 60 ft) — the entry size of U.S. Boiler Company's condensing stainless steel line.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
21–105 MBH
Output (max)
—
AFUE
95 %

The Burnham Alpine ALP105B fires 21 to 105 MBH input at 95.0% AFUE — 96 MBH DOE heating capacity and an 83 MBH net AHRI rating — in the wall-hung or floor-standing Alpine chassis, with the same 3" venting (2" option) as the ALP080B.

Natural gasPropaneHeating-only

Frequently asked questions

Which Alpine is more efficient?

Both are rated 95.0% AFUE per the Alpine I&O ratings table; efficiency does not separate them.

How much bigger is the ALP105B than the ALP080B?

Input rises from 80 to 105 MBH maximum, DOE heating capacity from 72 to 96 MBH, net AHRI from 63 to 83 MBH, and shipping weight from 137 to 155 lb.

Do both vent the same way?

Yes — 3" CPVC/PVC to 135 ft maximum equivalent each for intake and vent, with the same optional 2" build limited to 60 ft.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate