Burnham Alpine ALP105B

The Burnham Alpine ALP105B fires 21 to 105 MBH input at 95.0% AFUE — 96 MBH DOE heating capacity and an 83 MBH net AHRI rating — in the wall-hung or floor-standing Alpine chassis, with the same 3" venting (2" option) as the ALP080B.

CurrentCanadian status unknown

Key figures

Max input
105 MBH
Max CSA output
AFUE
95 %
Min input
21 MBH
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Burnham Alpine ALP105B in practice

The ALP105B steps the Alpine line to 21–105 MBH input with 96 MBH DOE heating capacity and an 83 MBH net AHRI water rating at 95.0% AFUE (Table 1-5, Alpine I&O Manual 103448-12). It shares the family's condensing stainless steel coil heat exchanger (ASME Section IV), Sage2.X outdoor-reset control and 5:1 modulation, and runs identical inputs on natural gas and propane.

At 155 lb shipping weight it connects on 1/2" FPT gas and 1" FPT supply/return and is rated 160 psi MAWP with a 30 psi standard relief valve. Venting is 3" CPVC/PVC to 135 ft maximum equivalent intake and vent, with the same reduced 2" option to 60 ft as the 080B. Above 2,000 ft elevation the ratings derate 2.5% per 1,000 ft; a licensed contractor performs installation, gas and venting work against the manual.

Best suited to

  • Detached homes whose heat-loss calculation exceeds the ALP080B's 80 MBH ceiling
  • Small commercial-adjacent loads still within 105 MBH input
  • Projects wanting the 3" vent run (135 ft) with the optional 2" route kept for tight spaces

Applicability and support

Model number
ALP105B
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Burnham. Units are shown with every value; notes flag conflicting sources or missing figures.

Burnham Alpine ALP105B specifications
SpecificationValueNote
Input
Input, minimum21 MBHMinimum input at sea level–2,000 ft per Table 1-5 (Alpine I&O Manual 103448-12). Min/max inputs give 5:1 modulation.
Input, maximum105 MBHMaximum input at sea level–2,000 ft per Table 1-5. Identical on NG and LP (ships NG, field LP-conversion kit).
Output
DOE heating capacity96 MBHDOE heating capacity at maximum input per Table 1-5.
Net AHRI water rating83 MBHNet AHRI water rating per Table 1-5.
Efficiency
Efficiency (AFUE)95 %95.0% AFUE per the Alpine ratings table (Table 1-5); the product page states 95% AFUE with ENERGY STAR certification.
Domestic hot water
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Venting and air
Vent connection3" CPVC/PVC (optional 2" reduced-length build)3" standard build to 135 ft max equivalent intake and vent; the optional reduced 2" build is limited to 60 ft (Tables 4-2/4-3).
Physical and connections
Shipping weight155 lbShipping weight per Table 1-5.
Gas connection1/2" FPTFemale NPT per the Alpine I&O manual specifications.
Supply/return connections1" FPTFemale NPT per the Alpine I&O manual specifications; condensate connection 3/4" PVC compression socket; relief/drain tapping 3/4" FPT.
Operating limits and other
FuelNatural gas or propaneInputs identical on NG and LP; boiler ships configured for natural gas with a field LP-conversion kit.

Frequently asked questions

How does the ALP105B compare with the ALP080B?

Input rises from 16–80 to 21–105 MBH, DOE heating capacity from 72 to 96 MBH and net AHRI from 63 to 83 MBH; both are 95.0% AFUE with the same 3"/2" venting options, and the 105B is 18 lb heavier (155 lb shipping).

Does the ALP105B produce domestic hot water?

No. It is heating-only; an indirect tank or separate water heater supplies DHW.

What is the ALP105B's vent limit in 3" pipe?

135 ft maximum equivalent each for intake and vent in the standard 3" CPVC/PVC build; the reduced 2" build is limited to 60 ft.

Questions about the Burnham Alpine ALP105B?