Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

Burnham Alpine ALP150B vs ALP210B

Verdict in brief

The ALP150B and ALP210B are 95.0% AFUE Alpines in the same wall-hung-or-floor chassis class: the 210B adds 60 MBH of input ceiling (150 to 210 MBH) for 58 MBH more DOE heating capacity (136 to 194 MBH) and a 51 MBH higher net AHRI rating (118 to 169 MBH), with the vent-side limit growing from 100 to 135 ft.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Burnham Alpine ALP150B and Burnham Alpine ALP210B
SpecificationBurnham Alpine ALP150BBurnham Alpine ALP210B
Input, minimum30 MBH42 MBH
Input, maximum150 MBH210 MBH
DOE heating capacity136 MBH194 MBH
Net AHRI water rating118 MBH169 MBH
Efficiency (AFUE)95 %95 %
Vent connection3" CPVC/PVC3" CPVC/PVC
Shipping weight182 lb206 lb
Gas connection1/2" FPT1/2" FPT
Supply/return connections1" FPT1" FPT
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heaterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater

What actually separates them

Both models carry the family's 95.0% AFUE rating, stainless steel coil heat exchanger, Sage2.X control, 5:1 modulation, 1/2" FPT gas connection and 1" FPT supply/return, and both may be wall-hung or floor-standing.

The 210B raises maximum input from 150 to 210 MBH (minimum from 30 to 42 MBH). The ratings table prints 194 MBH DOE heating capacity and a 169 MBH net AHRI water rating for the 210B, against 136 MBH and 118 MBH for the 150B.

Both vent in 3" CPVC/PVC; the 210B reaches 135 ft maximum equivalent on intake AND vent, while the 150B's vent side is limited to 100 ft. Shipping weight grows from 182 to 206 lb.

CurrentCanadian status unknown
Input
30–150 MBH
Output (max)
—
AFUE
95 %

The Burnham Alpine ALP150B is the mid-size Alpine: 30 to 150 MBH input at 95.0% AFUE with 136 MBH DOE heating capacity and a 118 MBH net AHRI rating, wall-hung or floor-standing at 182 lb, vented in 3" pipe to 135 ft intake / 100 ft vent.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
42–210 MBH
Output (max)
—
AFUE
95 %

The Burnham Alpine ALP210B is the largest wall-hung-or-floor Alpine: 42 to 210 MBH input at 95.0% AFUE with 194 MBH DOE heating capacity and a 169 MBH net AHRI rating, vented in 3" pipe to 135 ft on both intake and vent.

Natural gasPropaneHeating-only

Frequently asked questions

What does the ALP210B add over the ALP150B?

Input rises from 150 to 210 MBH maximum, DOE heating capacity from 136 to 194 MBH, net AHRI from 118 to 169 MBH, and shipping weight from 182 to 206 lb.

Do the two sizes vent differently?

Both are 3" CPVC/PVC; the 210B allows 135 ft maximum equivalent on intake and vent, while the 150B's vent side stops at 100 ft.

Is either size wall-hung?

Yes — both may be wall-hung or floor-standing; only the ALP285B is floor-only.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate