Skip to content
Boilers.caby ROMA Heating & Cooling

Burnham · Burnham Alpine

Burnham Alpine ALP150B

The Burnham Alpine ALP150B is the mid-size Alpine: 30 to 150 MBH input at 95.0% AFUE with 136 MBH DOE heating capacity and a 118 MBH net AHRI rating, wall-hung or floor-standing at 182 lb, vented in 3" pipe to 135 ft intake / 100 ft vent.

CurrentCanadian status unknown

Key figures

Max input
150 MBH
Max CSA output
AFUE
95 %
Min input
30 MBH
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Burnham Alpine ALP150B in practice

The ALP150B covers the middle of the Alpine range at 30–150 MBH input, printing 136 MBH DOE heating capacity and a 118 MBH net AHRI water rating at 95.0% AFUE (Table 1-5, Alpine I&O Manual 103448-12). As with every Alpine size it is a condensing boiler with a stainless steel coil heat exchanger, outdoor-reset Sage2.X control and 5:1 modulation on identical NG/LP inputs.

It is wall-hung or floor-standing, ships at 182 lb, and keeps the family's 1/2" FPT gas and 1" FPT supply/return connections with a 160 psi MAWP rating and 30 psi standard relief. Venting is 3" only — CPVC/PVC to 135 ft maximum equivalent intake and 100 ft vent, with no 2" option on this size. Elevation ratings to 2,000 ft apply, with a 2.5% derate per 1,000 ft above; a licensed contractor handles installation and gas work.

Best suited to

  • Larger detached homes whose heat-loss calculation lands between 105 and 150 MBH
  • Homes pairing the boiler with an indirect tank that adds recovery demand
  • Projects with a 3" vent route up to 100 ft (vent side) or 135 ft (intake)

Applicability and support

Model number
ALP150B
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Burnham. Units are shown with every value; notes flag conflicting sources or missing figures.

Burnham Alpine ALP150B specifications
SpecificationValueNote
Input
Input, minimum30 MBHMinimum input at sea level–2,000 ft per Table 1-5 (Alpine I&O Manual 103448-12). Min/max inputs give 5:1 modulation.
Input, maximum150 MBHMaximum input at sea level–2,000 ft per Table 1-5. Identical on NG and LP (ships NG, field LP-conversion kit).
Output
DOE heating capacity136 MBHDOE heating capacity at maximum input per Table 1-5.
Net AHRI water rating118 MBHNet AHRI water rating per Table 1-5.
Efficiency
Efficiency (AFUE)95 %95.0% AFUE per the Alpine ratings table (Table 1-5); the product page states 95% AFUE with ENERGY STAR certification.
Domestic hot water
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Venting and air
Vent connection3" CPVC/PVC3" build to 135 ft max equivalent intake and 100 ft max equivalent vent (Tables 4-2/4-3).
Physical and connections
Shipping weight182 lbShipping weight per Table 1-5.
Gas connection1/2" FPTFemale NPT per the Alpine I&O manual specifications.
Supply/return connections1" FPTFemale NPT per the Alpine I&O manual specifications; condensate connection 3/4" PVC compression socket; relief/drain tapping 3/4" FPT.
Operating limits and other
FuelNatural gas or propaneInputs identical on NG and LP; boiler ships configured for natural gas with a field LP-conversion kit.

Frequently asked questions

What are the ALP150B's ratings?

30–150 MBH input, 136 MBH DOE heating capacity, a 118 MBH net AHRI water rating and 95.0% AFUE per the Alpine I&O ratings table.

Can the ALP150B vent in 2" pipe?

No — this size vents in 3" only, to 135 ft maximum equivalent intake and 100 ft maximum equivalent vent.

Is the ALP150B wall-hung?

Yes — like the ALP080B through ALP210B it may be wall-hung or floor-standing; the ALP285B is floor-only.

Questions about the Burnham Alpine ALP150B?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate