Bradford White Brute FT BFTHW-301 vs BFTHW-399

Verdict in brief

The BFTHW-301 and BFTHW-399 are the two Brute FT boiler sizes Bradford White lists for Canada and share the same wall-hung condensing chassis, 39,900 Btu/h minimum fire, connections, venting and 80 psig MAWP. The 399 adds 98 MBH of input ceiling (399,000 against 301,000 Btu/h), printing a 10:1 turndown and slightly higher AHRI efficiencies (95.9%/95.4% vs 95.4%/95.1%); it weighs about 10 lb more and its Net AHRI water rating rises from 249 to 330 MBH.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Bradford White Brute FT BFTHW-301 and Bradford White Brute FT BFTHW-399
SpecificationBradford White Brute FT BFTHW-301Bradford White Brute FT BFTHW-399
Maximum input301 MBH399 MBH
Minimum input39.9 MBH39.9 MBH
Turndown ratio7.5:110:1
Combustion efficiency (AHRI)95.4 %95.9 %
Thermal efficiency (AHRI)95.1 %95.4 %
Gross output286 MBH379 MBH
Net AHRI water rating249 MBH330 MBH
Max. equivalent vent length, 3"65 ft65 ft
Max. equivalent vent length, 4"150 ft150 ft
Water connections1½" NPT1½" NPT
Gas connection1" NPT1" NPT
Gas supply pressureNG 3.5–10.5 / LP 8.0–13.0 in. w.c.NG 3.5–10.5 / LP 8.0–13.0 in. w.c.
Maximum allowable working pressure (MAWP)80 psig80 psig
Product weight240 lb250 lb
Water capacity11.3 gal10 gal
Domestic hot waterNone built in — heating-only hydronic boiler; indirect tank supported through DHW sensor logicNone built in — heating-only hydronic boiler; indirect tank supported through DHW sensor logic

What actually separates them

Both BFTHW models are the only Brute units currently listed on Bradford White's official Canada catalogue — boiler-type condensing, wall-hung heating-only units (floor stand optional) that share one chassis, one installation manual (Document 1538D) and the same 32.7" × 25.4" × 20.7" dimensions. Water connections (1½" NPT), gas connection (1" NPT), vent limits (3" to 65 or 4" to 150 equivalent ft) and the 80 psig MAWP with 30 psi ASME relief valve are identical between the two sizes.

The 399 exists for capacity: its 399,000 Btu/h maximum input against the 301's 301,000 Btu/h prints a gross output of 379 MBH and a Net AHRI water rating of 330 MBH, versus 286 and 249 MBH on the 301. Because both start from the same 39,900 Btu/h minimum fire, the 399's printed turndown is the deeper 10:1 against the 301's 7.5:1, and it carries marginally higher AHRI figures — 95.9% combustion and 95.4% thermal efficiency versus 95.4% and 95.1%.

The remaining differences are physical: the 399 weighs 250 lb against the 301's 240 lb (product, before shipping or the floor-stand accessory), and its printed water capacity is 10.0 gal against the 301's 11.3 gal. Neither model produces domestic hot water — both are heating-only boilers that support an indirect tank through DHW sensor logic — so the choice between them follows a heat-loss calculation: the 399 earns its extra 98 MBH only when the design-day load and any recovery demand approach the 301's ceiling.

CurrentSold in Canada
Input
39.9–301 MBH
Output (max)
—
AFUE
—

The Bradford White Brute FT BFTHW-301 is a wall-hung condensing, heating-only hydronic boiler (floor stand optional) rated at 301,000 Btu/h maximum input with 7.5:1 turndown, printing 95.4% combustion and 95.1% thermal efficiency — one of only two Brute models currently listed for Canada.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
39.9–399 MBH
Output (max)
—
AFUE
—

The Bradford White Brute FT BFTHW-399 is the top Brute FT boiler for Canada: a wall-hung condensing, heating-only hydronic boiler (floor stand optional) rated at 399,000 Btu/h maximum input with 10:1 turndown, printing 95.9% combustion and 95.4% thermal efficiency.

Natural gasPropaneHeating-only

Frequently asked questions

Which Brute FT model is bigger?

The BFTHW-399: it fires to 399,000 Btu/h against the BFTHW-301's 301,000 Btu/h and prints 379 MBH gross output and a 330 MBH Net AHRI water rating. Both models share the same chassis and 32.7" × 25.4" × 20.7" dimensions.

Do the two models have the same venting?

Yes. Both are sealed-combustion Category IV units vented in 3" to 65 equivalent ft or 4" to 150 equivalent ft, with the same 1½" NPT water and 1" NPT gas connections.

When should I choose the BFTHW-301 over the BFTHW-399?

When a heat-loss calculation shows the building needs less than the 301's ceiling on a design day. Both boilers start at the same 39,900 Btu/h minimum fire, so a building that never approaches 301 MBH gets no benefit from the 399's extra input and its slightly higher weight.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.