The Bradford White Brute FT BFTHW-399 is the top Brute FT boiler for Canada: a wall-hung condensing, heating-only hydronic boiler (floor stand optional) rated at 399,000 Btu/h maximum input with 10:1 turndown, printing 95.9% combustion and 95.4% thermal efficiency.
Key figures
- Max input
- 399 MBH
- Max CSA output
- —
- AFUE
- —
- Min input
- 39.9 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Bradford White Brute FT BFTHW-399 in practice
The BFTHW-399 is the larger of the two Brute FT boiler-type condensing units Bradford White lists for Canada (model number printed on the official Canada and US catalogues as BFTHW-399). It shares the BFTHW-301's wall-hung chassis with a floor-stand accessory option but fires to 399,000 Btu/h from the same 39,900 Btu/h minimum — a printed 10:1 turndown — with AHRI certified combustion and thermal efficiencies of 95.9% and 95.4%.
The official sizing data prints a gross output of 379 MBH and a Net AHRI water rating of 330 MBH, with an 80 psig MAWP (ASME "H" stamp) and a 30 psi ASME pressure relief valve. Venting is sealed-combustion Category IV in 3" to 65 equivalent ft or 4" to 150 equivalent ft, with 1½" NPT system supply/return and 1" NPT gas connections, on the NGTB-1000C control with outdoor reset and cascade to four units.
Like the BFTHW-301, the Brute FT is heating-only, not a combi — domestic hot water comes from a separate tank supported through the boiler's DHW sensor logic. With the other Brute lines marked 'No Longer Available in Canada' on the official Canada catalogue, the BFTHW-399 is the top-input Brute size a Canadian buyer can currently specify; its extra 98 MBH of ceiling over the 301 earns its place only when a heat-loss calculation genuinely needs it.
Best suited to
- Larger homes and light-commercial plants whose heat-loss calculation approaches the 399 MBH input ceiling
- Heating-only hydronic systems feeding radiators or in-floor loops with a separate indirect tank
- Projects wanting the full Brute FT modulation depth (10:1) at the top Canadian-listed input
Applicability and support
- Model number
- BFTHW-399
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Bradford White. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Maximum input | 399 MBH | 399,000 Btu/h (117 kW), as printed in the sizing data (Submittal 1540; I&O Section 2.3). |
| Minimum input | 39.9 MBH | 39,900 Btu/h as printed — the same minimum fire rate is printed for the BFTHW-301. |
| Output | ||
| Gross output | 379 MBH | 379 MBH (111 kW) as printed in the sizing data. |
| Net AHRI water rating | 330 MBH | 330 MBH (97 kW) as printed in the sizing data. |
| Efficiency | ||
| Combustion efficiency (AHRI) | 95.9 % | AHRI certified combustion efficiency as printed (95.9%); product-page copy states 95%+ AHRI certified. |
| Thermal efficiency (AHRI) | 95.4 % | AHRI certified thermal efficiency as printed (95.4%). |
| Domestic hot water | ||
| Domestic hot water | None built in — heating-only hydronic boiler; indirect tank supported through DHW sensor logic | Not a combi: rated for hydronic heating with indirect DHW via tank sensor logic, as printed. |
| Venting and air | ||
| Max. equivalent vent length, 3" | 65 ft | 3" venting to 65 equivalent ft as printed. |
| Max. equivalent vent length, 4" | 150 ft | 4" venting to 150 equivalent ft as printed. |
| Venting | Sealed combustion, Category IV — single, concentric or direct vent | 3" venting to 65 equivalent ft or 4" venting to 150 equivalent ft; CPVC, polypropylene (incl. flexible), PVC and stainless flue; air intake in ABS, PVC, CPVC, PP or galvanized material. |
| Physical and connections | ||
| Product weight | 250 lb | 250 lb (114 kg); shipping weight 275 lb (125 kg). With the floor-stand accessory: 285 lb product and 320 lb shipping, as printed. |
| Height | 32.7 in | H × W × D as printed; the BFTHW-301 and BFTHW-399 share the same chassis dimensions. |
| Width | 25.4 in | |
| Depth | 20.7 in | |
| Water capacity | 10 gal | 10.0 gal (80 lb), as printed. |
| Water connections | 1½" NPT | System supply and return, top and bottom (as printed). |
| Gas connection | 1" NPT | |
| Condensate line | ½" OD | |
| Electrical | ||
| Electrical | 120 V / 60 Hz on a 15 A circuit (<4 A draw); 24 VAC controls | |
| Operating limits and other | ||
| Turndown ratio | 10:1 | 10:1 as printed in the sizing data (399 ÷ 39.9 = 10:1). |
| Fuel | Natural gas or propane | Natural gas is the factory configuration; the propane conversion kit is included with the unit (field conversion, as printed). |
| Gas supply pressure | NG 3.5–10.5 / LP 8.0–13.0 in. w.c. | Natural-gas inlet 3.5–10.5" w.c.; propane inlet 8.0–13.0" w.c., as printed. |
| Maximum allowable working pressure (MAWP) | 80 psig | 80 psi (551 kPa); ASME "H" stamp with National Board listing, as printed. |
| Pressure relief valve | 30 psig | 30 psi (207 kPa) ASME PRV, as printed on the product page feature list. |
| Controls & cascade | NGTB-1000C main controller with P-953EH display; PID modulation; outdoor reset sensor included; cascade up to 4 units (mixed sizes allowed); 0–10 VDC; Modbus via gateway | |
| Burner | Single-orifice premix burner, ceramic fiber; direct spark ignition | |
| Heat exchanger | Stainless steel heat exchanger with finned-aluminum-core fire tubes | 10-year limited heat exchanger warranty, as printed. |
Frequently asked questions
How does the BFTHW-399 differ from the BFTHW-301?
Both are the same wall-hung condensing Brute FT chassis with the same 39,900 Btu/h minimum fire, but the 399 fires to 399,000 Btu/h (10:1 turndown) against the 301's 301,000 Btu/h (7.5:1), prints 95.9%/95.4% combustion/thermal efficiency and is about 10 lb heavier.
Is the BFTHW-399 a combi boiler?
No. The Brute FT line is heating-only — the BFTHW-399 produces no domestic hot water itself. It pairs with a separate indirect tank through the control's DHW sensor logic.
What venting does the BFTHW-399 need?
Sealed-combustion Category IV venting: 3" to 65 equivalent ft or 4" to 150 equivalent ft, single, concentric or direct, as printed. Canadian plastic venting must comply with the applicable codes (ULC S636 where required).
Questions about the Bradford White Brute FT BFTHW-399?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- Bradford White Canada — Brute FT Wall-Hung & Floor Standing Boilers (BFTHW), model numbers BFTHW-301 / BFTHW-399 · accessed September 8, 2026
- Bradford White — Brute FT Wall-Hung & Floor Standing Boilers (BFTHW), model numbers BFTHW-301 / BFTHW-399 · accessed September 8, 2026
- Bradford White — Brute FT BFTHW spec sheet, 5084-112 (Current) · 5084-112 · accessed September 8, 2026
- Bradford White — Brute FT BFTHW submittal, 1540 (Current) · 1540 · accessed September 8, 2026
- Bradford White — Brute FT installation and operation instructions, Document 1538D · 1538D · accessed September 8, 2026
Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.