Bradford White Brute FT BFTHW-301

The Bradford White Brute FT BFTHW-301 is a wall-hung condensing, heating-only hydronic boiler (floor stand optional) rated at 301,000 Btu/h maximum input with 7.5:1 turndown, printing 95.4% combustion and 95.1% thermal efficiency — one of only two Brute models currently listed for Canada.

CurrentSold in Canada

Key figures

Max input
301 MBH
Max CSA output
AFUE
Min input
39.9 MBH
Natural gasPropaneHeating-onlyresidentialcommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Bradford White Brute FT BFTHW-301 in practice

The BFTHW-301 is the smaller of the two Brute FT boiler-type condensing units Bradford White lists for Canada (model number printed on the official Canada and US catalogues as BFTHW-301). It is a wall-hung unit with a floor-stand accessory option, rated for 301,000 Btu/h maximum input with a 39,900 Btu/h minimum fire — a printed 7.5:1 turndown — and it prints AHRI certified combustion and thermal efficiencies of 95.4% and 95.1%.

The official sizing data prints a gross output of 286 MBH and a Net AHRI water rating of 249 MBH, with an 80 psig MAWP (ASME "H" stamp) and a 30 psi ASME pressure relief valve. The sealed-combustion Category IV boiler vents in 3" to 65 equivalent ft or 4" to 150 equivalent ft and connects with 1½" NPT system supply/return and 1" NPT gas, on the NGTB-1000C control with outdoor reset and cascade to four units.

The Brute FT is heating-only, not a combi: domestic hot water is handled by a separate tank, which the boiler supports through its DHW sensor logic. Because the other Brute boiler and volume-water-heater lines are marked 'No Longer Available in Canada' on the official Canada catalogue, the BFTHW-301 is one of the two Brute sizes a Canadian buyer can currently specify — always sized from a heat-loss calculation and installed by a licensed contractor.

Best suited to

  • Homes and light-commercial spaces whose heat-loss calculation fits within the 301 MBH input ceiling
  • Heating-only hydronic plants paired with a separate indirect tank
  • Wall-hung (or optional floor-stand) mechanical rooms needing sealed-combustion Category IV venting in 3" or 4"

Applicability and support

Model number
BFTHW-301
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Bradford White. Units are shown with every value; notes flag conflicting sources or missing figures.

Bradford White Brute FT BFTHW-301 specifications
SpecificationValueNote
Input
Maximum input301 MBH301,000 Btu/h (88 kW), as printed in the sizing data (Submittal 1540; I&O Section 2.3).
Minimum input39.9 MBH39,900 Btu/h as printed — the same minimum fire rate is printed for the BFTHW-399.
Output
Gross output286 MBH286 MBH (84 kW) as printed in the sizing data.
Net AHRI water rating249 MBH249 MBH (73 kW) as printed in the sizing data.
Efficiency
Combustion efficiency (AHRI)95.4 %AHRI certified combustion efficiency as printed (95.4%); product-page copy states 95%+ AHRI certified.
Thermal efficiency (AHRI)95.1 %AHRI certified thermal efficiency as printed (95.1%).
Domestic hot water
Domestic hot waterNone built in — heating-only hydronic boiler; indirect tank supported through DHW sensor logicNot a combi: rated for hydronic heating with indirect DHW via tank sensor logic, as printed.
Venting and air
Max. equivalent vent length, 3"65 ft3" venting to 65 equivalent ft as printed.
Max. equivalent vent length, 4"150 ft4" venting to 150 equivalent ft as printed.
VentingSealed combustion, Category IV — single, concentric or direct vent3" venting to 65 equivalent ft or 4" venting to 150 equivalent ft; CPVC, polypropylene (incl. flexible), PVC and stainless flue; air intake in ABS, PVC, CPVC, PP or galvanized material.
Physical and connections
Product weight240 lb240 lb (109 kg); shipping weight 265 lb (120 kg). With the floor-stand accessory: 275 lb product and 310 lb shipping, as printed.
Height32.7 inH × W × D as printed; the BFTHW-301 and BFTHW-399 share the same chassis dimensions.
Width25.4 in
Depth20.7 in
Water capacity11.3 gal11.3 gal (90 lb), as printed.
Water connections1½" NPTSystem supply and return, top and bottom (as printed).
Gas connection1" NPT
Condensate line½" OD
Electrical
Electrical120 V / 60 Hz on a 15 A circuit (<4 A draw); 24 VAC controls
Operating limits and other
Turndown ratio7.5:17.5:1 as printed in the sizing data (301 ÷ 39.9 = 7.5:1).
FuelNatural gas or propaneNatural gas is the factory configuration; the propane conversion kit is included with the unit (field conversion, as printed).
Gas supply pressureNG 3.5–10.5 / LP 8.0–13.0 in. w.c.Natural-gas inlet 3.5–10.5" w.c.; propane inlet 8.0–13.0" w.c., as printed.
Maximum allowable working pressure (MAWP)80 psig80 psi (551 kPa); ASME "H" stamp with National Board listing, as printed.
Pressure relief valve30 psig30 psi (207 kPa) ASME PRV, as printed on the product page feature list.
Controls & cascadeNGTB-1000C main controller with P-953EH display; PID modulation; outdoor reset sensor included; cascade up to 4 units (mixed sizes allowed); 0–10 VDC; Modbus via gateway
BurnerSingle-orifice premix burner, ceramic fiber; direct spark ignition
Heat exchangerStainless steel heat exchanger with finned-aluminum-core fire tubes10-year limited heat exchanger warranty, as printed.

Frequently asked questions

Is the BFTHW-301 available in Canada?

Yes. The BFTHW-301 is one of two Brute FT models (BFTHW-301 and BFTHW-399) listed on Bradford White's official Canada catalogue for the Brute FT wall-hung and floor-standing boilers; the other Brute lines are marked 'No Longer Available in Canada'.

What is the BFTHW-301's minimum fire rate?

39,900 Btu/h — the same printed minimum input as the BFTHW-399. Against its 301,000 Btu/h maximum the BFTHW-301 prints a 7.5:1 turndown.

Does the BFTHW-301 produce domestic hot water?

No. The Brute FT is a heating-only hydronic boiler, not a combi. Domestic hot water comes from a separate tank, which the boiler supports through its DHW sensor logic.

Questions about the Bradford White Brute FT BFTHW-301?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.