Burnham ES2 ES25 vs ES26

Verdict in brief

The ES25 and ES26 are the two ES2 sizes that share the 6" draft hood: the ES26 fires 175 MBH fixed input against the ES25's 140 MBH, lifting DOE heating capacity from 119 to 149 MBH and the net AHRI rating from 103 to 130 MBH, at 405 lb shipping versus 357 lb.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Burnham ES2 ES25 and Burnham ES2 ES26
SpecificationBurnham ES2 ES25Burnham ES2 ES26
Input140 MBH175 MBH
DOE heating capacity119 MBH149 MBH
Net AHRI water rating103 MBH130 MBH
Efficiency (AFUE)85 %85 %
VentingCategory I natural draft — draft hood into an existing lined chimney (Type B/L gas vent); 6" draft hoodCategory I natural draft — draft hood into an existing lined chimney (Type B/L gas vent); 6" draft hood
Shipping weight357 lb405 lb
Gas connection1/2" NPT1/2" NPT
Supply/return connections1-1/4" NPT1-1/4" NPT
Maximum allowable working pressure (MAWP)50 psi50 psi
Electrical120 VAC, 60 Hz, 1-phase, 15 A120 VAC, 60 Hz, 1-phase, 15 A

What actually separates them

Both ES2 boilers are non-condensing cast iron at 85% AFUE with fixed inputs, and both vent as Category I natural draft through the same 6" draft-hood connector into an existing lined chimney.

The ES26 adds 35 MBH of fixed input over the ES25 (175 vs 140 MBH), which the ratings table turns into 149 MBH DOE heating capacity and a 130 MBH net AHRI water rating versus 119 and 103 MBH.

Both connect on 1-1/4" NPT supply/return with 1/2" NPT gas and run the IQ control at 50 psi MAWP (30 psi shipped relief). Shipping weight grows from 357 lb (284 lb empty) on the ES25 to 405 lb (332 lb empty) on the ES26.

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
85 %

The Burnham ES2 ES25 fires a fixed 140 MBH input for 119 MBH DOE heating capacity and a 103 MBH net AHRI rating at 85% AFUE — the first 6" draft-hood size of the non-condensing, Category I ES2 cast-iron line.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
85 %

The Burnham ES2 ES26 fires a fixed 175 MBH input for 149 MBH DOE heating capacity and a 130 MBH net AHRI rating at 85% AFUE, sharing the 6" draft hood with the ES25 in the non-condensing Category I ES2 line.

Natural gasPropaneHeating-only

Frequently asked questions

What separates the ES25 and ES26?

Fixed input (140 vs 175 MBH), DOE heating capacity (119 vs 149 MBH), net AHRI (103 vs 130 MBH) and shipping weight (357 vs 405 lb) — venting is the same 6" draft hood.

Do the ES25 and ES26 vent identically?

Yes — both carry the 6" draft hood for Category I natural-draft venting into an existing lined chimney.

Which is better for my home?

Neither is 'better' — the fixed input must match the heat-loss calculation. A 140 MBH fixed fire is already large for most homes; only a licensed contractor sizing from a heat-loss calculation should decide.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate