Burnham · Burnham ES2

Burnham ES2 ES26

The Burnham ES2 ES26 fires a fixed 175 MBH input for 149 MBH DOE heating capacity and a 130 MBH net AHRI rating at 85% AFUE, sharing the 6" draft hood with the ES25 in the non-condensing Category I ES2 line.

CurrentCanadian status unknown

Key figures

Max input
175 MBH
Max CSA output
AFUE
85 %
Min input
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Burnham ES2 ES26 in practice

The ES26 sits at the 175 MBH fixed-input mark of the ES2 series, printing 149 MBH DOE heating capacity and a 130 MBH net AHRI water rating at 85% AFUE (ES2 I&O ratings table, Doc 103780-11). It is a NON-condensing cast-iron boiler with a 6" natural-draft draft hood (shared with the ES25), vented Category I into an existing lined chimney.

The ES26 ships at 405 lb (332 lb empty), uses 1-1/4" NPT supply/return and 1/2" NPT gas, and runs the IQ Boiler Control System on natural or LP gas with optional outdoor-reset and LWCO IQ cards. Rated 50 psi MAWP with a 30 psi shipped relief valve, it operates at 130–220°F supply with a 110°F minimum return. Above 2,000 ft elevation the manual's Appendix G governs; sizing follows a heat-loss calculation and installation is licensed-contractor work.

Best suited to

  • Larger homes whose chimney-vented load requires a fixed 175 MBH input
  • Replacements matching an existing 6" chimney connector and draft hood
  • Non-condensing cast-iron projects that want simple IQ-control diagnostics

Applicability and support

Model number
ES26
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Burnham. Units are shown with every value; notes flag conflicting sources or missing figures.

Burnham ES2 ES26 specifications
SpecificationValueNote
Input
Input175 MBHFixed input (no modulation) per the ES2 ratings table (Doc 103780-11); ratings apply to elevations up to 2,000 ft.
Output
DOE heating capacity149 MBHPer the ES2 ratings table.
Net AHRI water rating130 MBHNet AHRI water rating based on a piping and pickup allowance of 1.15, per the ES2 ratings table.
Efficiency
Efficiency (AFUE)85 %85% AFUE — a NON-condensing rating; the ES2 is a natural-draft cast-iron boiler, not a condensing design.
Domestic hot water
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Venting and air
VentingCategory I natural draft — draft hood into an existing lined chimney (Type B/L gas vent); 6" draft hoodNon-condensing, natural-draft design: NOT a direct-vent or condensing boiler. Draft hood sizes per the ES2 I&O manual specifications.
Physical and connections
Shipping weight405 lbShipping weight 405 lb; empty (uncrated) boiler weight 332 lb, per the ES2 I&O manual weights and volume table.
Supply/return connections1-1/4" NPTSupply and return both 1-1/4" NPT; relief valve 3/4" and drain 3/4" per the ES2 I&O manual.
Gas connection1/2" NPT1/2" NPT gas connection (ES23–ES26); ES27–ES29 use 3/4" NPT.
Electrical
Electrical120 VAC, 60 Hz, 1-phase, 15 APer the ES2 I&O manual specifications.
Operating limits and other
Maximum allowable working pressure (MAWP)50 psi50 psi MAWP; the boiler ships from the factory with a 30 psi safety relief valve.
ControlIQ Boiler Control SystemIQ control with optional outdoor-reset and LWCO IQ option cards; the control flashes 'Err' + number for faults.

Frequently asked questions

What are the ES26's ratings?

175 MBH fixed input, 149 MBH DOE heating capacity, a 130 MBH net AHRI water rating and 85% AFUE per the ES2 ratings table.

What are the ES26's connections?

1-1/4" NPT supply and return with 1/2" NPT gas; the 50 psi MAWP boiler ships with a 30 psi relief valve.

How heavy is the ES26?

405 lb shipping weight, 332 lb empty, per the ES2 I&O manual weights and volume table.

Questions about the Burnham ES2 ES26?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate