Burnham ES2 ES25
The Burnham ES2 ES25 fires a fixed 140 MBH input for 119 MBH DOE heating capacity and a 103 MBH net AHRI rating at 85% AFUE — the first 6" draft-hood size of the non-condensing, Category I ES2 cast-iron line.
Key figures
- Max input
- 140 MBH
- Max CSA output
- —
- AFUE
- 85 %
- Min input
- —
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Burnham ES2 ES25 in practice
The ES25 is the mid-small ES2 size at a fixed 140 MBH input, printing 119 MBH DOE heating capacity and a 103 MBH net AHRI water rating at 85% AFUE (ES2 I&O ratings table, Doc 103780-11). The 6" draft hood on this size (shared with the ES26) feeds a Category I natural-draft connection into an existing lined chimney — the ES2 is a NON-condensing, chimney-replacement boiler, not a direct-vent design.
At 357 lb shipping (284 lb empty), the ES25 connects on 1-1/4" NPT supply/return with 1/2" NPT gas, and runs the IQ Boiler Control System with optional outdoor-reset/LWCO option cards on natural or LP gas. MAWP is 50 psi (30 psi relief valve shipped); supply water runs 130–220°F with a 110°F minimum return. Match the size to a heat-loss calculation and have a licensed contractor do the gas, venting and installation work.
Best suited to
- Mid-size homes whose chimney-vented load fits a fixed 140 MBH input
- Chimney replacements needing a 6" draft-hood boiler connection
- Owners who prefer cast-iron construction without condensing-mode maintenance
Applicability and support
- Model number
- ES25
- Canadian availability
- unknown
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Burnham. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input | 140 MBH | Fixed input (no modulation) per the ES2 ratings table (Doc 103780-11); ratings apply to elevations up to 2,000 ft. |
| Output | ||
| DOE heating capacity | 119 MBH | Per the ES2 ratings table. |
| Net AHRI water rating | 103 MBH | Net AHRI water rating based on a piping and pickup allowance of 1.15, per the ES2 ratings table. |
| Efficiency | ||
| Efficiency (AFUE) | 85 % | 85% AFUE — a NON-condensing rating; the ES2 is a natural-draft cast-iron boiler, not a condensing design. |
| Domestic hot water | ||
| Domestic hot water | Heating-only boiler — domestic hot water comes from a separate indirect tank or water heater | |
| Venting and air | ||
| Venting | Category I natural draft — draft hood into an existing lined chimney (Type B/L gas vent); 6" draft hood | Non-condensing, natural-draft design: NOT a direct-vent or condensing boiler. Draft hood sizes per the ES2 I&O manual specifications. |
| Physical and connections | ||
| Shipping weight | 357 lb | Shipping weight 357 lb; empty (uncrated) boiler weight 284 lb, per the ES2 I&O manual weights and volume table. |
| Supply/return connections | 1-1/4" NPT | Supply and return both 1-1/4" NPT; relief valve 3/4" and drain 3/4" per the ES2 I&O manual. |
| Gas connection | 1/2" NPT | 1/2" NPT gas connection (ES23–ES26); ES27–ES29 use 3/4" NPT. |
| Electrical | ||
| Electrical | 120 VAC, 60 Hz, 1-phase, 15 A | Per the ES2 I&O manual specifications. |
| Operating limits and other | ||
| Maximum allowable working pressure (MAWP) | 50 psi | 50 psi MAWP; the boiler ships from the factory with a 30 psi safety relief valve. |
| Control | IQ Boiler Control System | IQ control with optional outdoor-reset and LWCO IQ option cards; the control flashes 'Err' + number for faults. |
Frequently asked questions
What are the ES25's ratings?
140 MBH fixed input, 119 MBH DOE heating capacity, a 103 MBH net AHRI water rating and 85% AFUE per the ES2 ratings table.
Which ES2 models share the 6" draft hood?
The ES25 and ES26 both use a 6" draft hood; the ES23/ES24 use 4"/5", the ES27/ES28 use 7" and the ES29 uses 8".
Does the ES25 need a chimney?
Yes — it is a Category I natural-draft boiler designed to vent into an existing lined chimney through its draft hood (Type B/L gas vent).
Questions about the Burnham ES2 ES25?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- U.S. Boiler Company — ES2 High Efficiency Gas-Fired Water Boiler product page · accessed September 8, 2026
- U.S. Boiler Company — Technical Literature (Alpine/ES2 I&O manual listings) · accessed September 8, 2026
- ES2 Gas Boiler — Installation, Operating & Service Instructions, Doc 103780-11 (PDF) · 103780-11 · accessed September 8, 2026
Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.