Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

Burnham ES2 ES26 vs ES27

Verdict in brief

The ES27 crosses the 200 MBH line in the fixed-input ES2 series: 210 MBH input against the ES26's 175 MBH, for 178 MBH DOE heating capacity (149 on the ES26) and a 155 MBH net AHRI rating (130). It steps to a 7" draft hood, 3/4" NPT gas and 462 lb shipping weight.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Burnham ES2 ES26 and Burnham ES2 ES27
SpecificationBurnham ES2 ES26Burnham ES2 ES27
Input175 MBH210 MBH
DOE heating capacity149 MBH178 MBH
Net AHRI water rating130 MBH155 MBH
Efficiency (AFUE)85 %85 %
VentingCategory I natural draft — draft hood into an existing lined chimney (Type B/L gas vent); 6" draft hoodCategory I natural draft — draft hood into an existing lined chimney (Type B/L gas vent); 7" draft hood
Shipping weight405 lb462 lb
Gas connection1/2" NPT3/4" NPT
Supply/return connections1-1/4" NPT1-1/4" NPT
Maximum allowable working pressure (MAWP)50 psi50 psi
Electrical120 VAC, 60 Hz, 1-phase, 15 A120 VAC, 60 Hz, 1-phase, 15 A

What actually separates them

Both are non-condensing cast-iron ES2 boilers at 85% AFUE with fixed inputs and Category I draft-hood venting; neither modulates, and both run the IQ Boiler Control System on natural or LP gas.

The ES27 fires 210 MBH fixed input against the ES26's 175 MBH, printing 178 MBH DOE heating capacity and a 155 MBH net AHRI water rating versus 149 and 130 MBH.

The physical step is clear: the ES27 moves from the ES26's 6" draft hood to 7", its gas connection grows from 1/2" NPT to 3/4" NPT (the ES27–ES29 share this), and shipping weight rises from 405 to 462 lb (empty 332 to 382 lb). Supply/return stay 1-1/4" NPT and MAWP stays 50 psi with a 30 psi shipped relief valve.

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
85 %

The Burnham ES2 ES26 fires a fixed 175 MBH input for 149 MBH DOE heating capacity and a 130 MBH net AHRI rating at 85% AFUE, sharing the 6" draft hood with the ES25 in the non-condensing Category I ES2 line.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
85 %

The Burnham ES2 ES27 fires a fixed 210 MBH input for 178 MBH DOE heating capacity and a 155 MBH net AHRI rating at 85% AFUE, stepping to a 7" draft hood and 3/4" NPT gas in the non-condensing Category I ES2 cast-iron line.

Natural gasPropaneHeating-only

Frequently asked questions

What draft hood does the ES27 use?

A 7" draft hood — shared with the ES28 — for Category I natural-draft venting; the ES25 and ES26 use 6".

Does the ES27 need a bigger gas line than the ES26?

Yes — the ES27 (with the ES28 and ES29) connects on 3/4" NPT gas, while the ES23–ES26 use 1/2" NPT.

What are the ES27's ratings?

210 MBH fixed input, 178 MBH DOE heating capacity, a 155 MBH net AHRI water rating and 85% AFUE.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate