Burnham ES2 ES27

The Burnham ES2 ES27 fires a fixed 210 MBH input for 178 MBH DOE heating capacity and a 155 MBH net AHRI rating at 85% AFUE, stepping to a 7" draft hood and 3/4" NPT gas in the non-condensing Category I ES2 cast-iron line.

CurrentCanadian status unknown

Key figures

Max input
210 MBH
Max CSA output
—
AFUE
85 %
Min input
—
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Burnham ES2 ES27 in practice

The ES27 crosses into the large ES2 sizes at a fixed 210 MBH input, printing 178 MBH DOE heating capacity and a 155 MBH net AHRI water rating at 85% AFUE (ES2 I&O ratings table, Doc 103780-11). It is a NON-condensing cast-iron boiler with a 7" natural-draft draft hood (shared with the ES28), vented Category I into an existing lined chimney as a chimney-replacement design.

At 462 lb shipping (382 lb empty), the ES27 connects on 1-1/4" NPT supply/return and steps its gas connection to 3/4" NPT (ES27–ES29 use 3/4"; ES23–ES26 use 1/2"). It runs the IQ Boiler Control System with optional outdoor-reset/LWCO IQ cards on natural or LP gas, rated 50 psi MAWP with a 30 psi shipped relief valve. Supply water runs 130–220°F with a 110°F minimum return; a licensed contractor performs installation against the manual and local codes.

Best suited to

  • Large homes whose chimney-vented load fits a fixed 210 MBH input
  • Replacements needing a 7" draft-hood connector into an existing chimney
  • High-capacity cast-iron projects preferring simple fixed-input operation

Applicability and support

Model number
ES27
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Burnham. Units are shown with every value; notes flag conflicting sources or missing figures.

Burnham ES2 ES27 specifications
SpecificationValueNote
Input
Input210 MBHFixed input (no modulation) per the ES2 ratings table (Doc 103780-11); ratings apply to elevations up to 2,000 ft.
Output
DOE heating capacity178 MBHPer the ES2 ratings table.
Net AHRI water rating155 MBHNet AHRI water rating based on a piping and pickup allowance of 1.15, per the ES2 ratings table.
Efficiency
Efficiency (AFUE)85 %85% AFUE — a NON-condensing rating; the ES2 is a natural-draft cast-iron boiler, not a condensing design.
Domestic hot water
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Venting and air
VentingCategory I natural draft — draft hood into an existing lined chimney (Type B/L gas vent); 7" draft hoodNon-condensing, natural-draft design: NOT a direct-vent or condensing boiler. Draft hood sizes per the ES2 I&O manual specifications.
Physical and connections
Shipping weight462 lbShipping weight 462 lb; empty (uncrated) boiler weight 382 lb, per the ES2 I&O manual weights and volume table.
Supply/return connections1-1/4" NPTSupply and return both 1-1/4" NPT; relief valve 3/4" and drain 3/4" per the ES2 I&O manual.
Gas connection3/4" NPT3/4" NPT gas connection (ES27–ES29); ES23–ES26 use 1/2" NPT.
Electrical
Electrical120 VAC, 60 Hz, 1-phase, 15 APer the ES2 I&O manual specifications.
Operating limits and other
Maximum allowable working pressure (MAWP)50 psi50 psi MAWP; the boiler ships from the factory with a 30 psi safety relief valve.
ControlIQ Boiler Control SystemIQ control with optional outdoor-reset and LWCO IQ option cards; the control flashes 'Err' + number for faults.

Frequently asked questions

What are the ES27's ratings?

210 MBH fixed input, 178 MBH DOE heating capacity, a 155 MBH net AHRI water rating and 85% AFUE per the ES2 ratings table.

What gas connection does the ES27 use?

3/4" NPT — the ES27, ES28 and ES29 step up from the 1/2" NPT used on the ES23–ES26.

Does the ES27 vent through a chimney?

Yes — Category I natural draft with a 7" draft hood into an existing lined chimney (Type B/L gas vent).

Questions about the Burnham ES2 ES27?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate