Verdict in brief

The ES27 and ES28 are the two ES2 sizes that share the 7" draft hood and 3/4" NPT gas: the ES28 fires 245 MBH fixed input against the ES27's 210 MBH, lifting DOE heating capacity from 178 to 208 MBH and the net AHRI rating from 155 to 181 MBH, at 518 lb shipping versus 462 lb.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Burnham ES2 ES27 and Burnham ES2 ES28
SpecificationBurnham ES2 ES27Burnham ES2 ES28
Input210 MBH245 MBH
DOE heating capacity178 MBH208 MBH
Net AHRI water rating155 MBH181 MBH
Efficiency (AFUE)85 %85 %
VentingCategory I natural draft — draft hood into an existing lined chimney (Type B/L gas vent); 7" draft hoodCategory I natural draft — draft hood into an existing lined chimney (Type B/L gas vent); 7" draft hood
Shipping weight462 lb518 lb
Gas connection3/4" NPT3/4" NPT
Supply/return connections1-1/4" NPT1-1/4" NPT
Maximum allowable working pressure (MAWP)50 psi50 psi
Electrical120 VAC, 60 Hz, 1-phase, 15 A120 VAC, 60 Hz, 1-phase, 15 A

What actually separates them

Both are non-condensing cast-iron ES2 boilers at 85% AFUE with fixed inputs, Category I 7" draft-hood venting, 3/4" NPT gas and 1-1/4" NPT supply/return connections on the IQ control at 50 psi MAWP (30 psi shipped relief).

The ES28 raises the fixed input from 210 to 245 MBH, which the ratings table turns into 208 MBH DOE heating capacity and a 181 MBH net AHRI water rating versus 178 and 155 MBH on the ES27.

The weight difference matters on site: the ES28 ships at 518 lb (438 lb empty) against the ES27's 462 lb (382 lb empty) — the ES28 measures 35" deep by 27-3/4" wide by 41" high per the manual's dimensions table.

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
85 %

The Burnham ES2 ES27 fires a fixed 210 MBH input for 178 MBH DOE heating capacity and a 155 MBH net AHRI rating at 85% AFUE, stepping to a 7" draft hood and 3/4" NPT gas in the non-condensing Category I ES2 cast-iron line.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
85 %

The Burnham ES2 ES28 fires a fixed 245 MBH input for 208 MBH DOE heating capacity and a 181 MBH net AHRI rating at 85% AFUE, with a 7" draft hood and 3/4" NPT gas — the second-largest non-condensing ES2 cast-iron size.

Natural gasPropaneHeating-only

Frequently asked questions

What separates the ES27 and ES28?

Fixed input (210 vs 245 MBH), DOE heating capacity (178 vs 208 MBH), net AHRI (155 vs 181 MBH) and shipping weight (462 vs 518 lb).

Do both use 7" venting?

Yes — both carry the 7" draft hood for Category I natural-draft venting into an existing lined chimney.

Are their gas connections the same?

Yes — both connect on 3/4" NPT gas with 1-1/4" NPT supply/return.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate